What is State Space Analysis?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is State Space Analysis?


State Space Analysis Definition


State space analysis of control systems is a method to analyze both simple and complex systems using a set of variables to describe their behavior over time.


State Space Equations


Let us derive state space equations for the system which is linear and time invariant.


Let us consider multiple inputs and multiple outputs system which has r inputs and m output.


Where, r = u1, u2, u3 ……….. ur.


And m = y1, y2 ……….. ym.


Now we are taking n state variables to describe the given system hence n = x1, x2, ……….. xn.


Also we define input and output vectors as,


Transpose of input vectors,

 

Where, T is transpose of the matrix.


4ec21880208e50398e2147e2c94be95c.jpeg

 

Transpose of output vectors,

 

Where, T is transpose of the matrix.


Transpose of state vectors,

 

Where, T is transpose of the matrix.


These variables are related by a set of equations which are written below and are known as state space equations


2f6c48f719835461d76258222a75c74a.jpeg


Representation of State Model using Transfer Function


Decomposition : It is defined as the process of obtaining the state model from the given transfer function. Now we can decompose the transfer function using three different ways:


  • Direct decomposition,

  • Cascade or series decomposition,

  • Parallel decomposition.


In all the above decomposition methods we first convert the given transfer function into the differential equations which is also called the dynamic equations. After converting into differential equations we will take inverse Laplace transform of the above equation then corresponding to the type of decomposition we can create model. We can represent any type of transfer function in state model. We have various types of model like electrical model, mechanical model etc.


Expression of Transfer Matrix in terms of A, B, C and D. We define transfer matrix as the Laplace transform of output to the Laplace transform of input.On writing the state equations again and taking the Laplace transform of both the state equation (assuming initial conditions equal to zero) we have

 

We can write the equation as


Where, I is an identity matrix


Now substituting the value of X(s) in the equation Y(s) and putting D = 0 (means is a null matrix) we have


Inverse of matrix can substitute by adj of matrix divided by the determinant of the matrix, now on rewriting the expression we have of


|sI-A| is also known as characteristic equation when equated to zero.

 

e6b9367897ab964505ee2e0d51ac6aef.jpeg

 

Concept of Eigen Values and Eigen Vectors


The roots of characteristic equation that we have described above are known as eigen values or eigen values of matrix A.Now there are some properties related to eigen values and these properties are written below-


  • Any square matrix A and its transpose At have the same eigen values.



  • Sum of eigen values of any matrix A is equal to the trace of the matrix A.



  • Product of the eigen values of any matrix A is equal to the determinant of the matrix A.



  • If we multiply a scalar quantity to matrix A then the eigen values are also get multiplied by the same value of scalar.



  • If we inverse the given matrix A then its eigen values are also get inverses.



  • If all the elements of the matrix are real then the eigen values corresponding to that matrix are either real or exists in complex conjugate pair.



Now there exists one eigen vector corresponding to one Eigen value, if it satisfy the following condition (ek × I – A)Pk = 0. Where, k = 1, 2, 3, ……..n.

 


State Transition Matrix and Zero State Response


We are here interested in deriving the expressions for the state transition matrix and zero state response. Again taking the state equations that we have derived above and taking their Laplace transformation we have,

 

Now on rewriting the above equation we have

 

d0ebabef77893dcbbf49dc9134298e1e.jpeg

 

Let [sI-A] -1 = θ(s) and taking the inverse Laplace of the above equation we have

 

The expression θ(t) is known as state transition matrix.


 

3ea0118a055da16d7af19dc530ebf4fe.jpeg

 

L-1.θ(t)BU(s) = zero state response.

 

Now let us discuss some of the properties of the state transition matrix.

 

  • If we substitute t = 0 in the above equation then we will get 1. Mathematically we can write θ(0) =1.



  • If we substitute t = -t in the θ(t) then we will get inverse of θ(t). Mathematically we can write θ(-t) = [θ(t)]-1.


  • We also another important property [θ(t)]n = θ(nt). 


Give a tip and encourage the author!
Recommended
MVDC: Future of Efficient, Sustainable Power Grids
MVDC: Future of Efficient, Sustainable Power Grids
The Global Energy Landscape Is Undergoing a Fundamental Transformation toward a "fully electrified society," characterized by widespread carbon-neutral energy and the electrification of industry, transportation, and residential loads.In today’s context of high copper prices, critical mineral conflicts, and congested AC power grids, Medium-Voltage Direct Current (MVDC) systems can overcome many limitations of traditional AC networks. MVDC significantly enhances transmission capacity and efficienc
Edwiin
10/21/2025
Grounding Causes of Cable Lines and the Principles of Incident Handling
Grounding Causes of Cable Lines and the Principles of Incident Handling
Our 220 kV substation is located far from the urban center in a remote area, surrounded primarily by industrial zones such as Lanshan, Hebin, and Tasha Industrial Parks. Major high-load consumers in these zones—including silicon carbide, ferroalloy, and calcium carbide plants—account for approximately 83.87% of our bureau’s total load. The substation operates at voltage levels of 220 kV, 110 kV, and 35 kV.The 35 kV low-voltage side mainly supplies feeders to ferroalloy and silicon carbide plants
Felix Spark
10/21/2025
Overhead Power Lines & Towers: Types, Design & Safety
Overhead Power Lines & Towers: Types, Design & Safety
Besides ultra-high voltage AC substations, what we encounter more frequently are power transmission and distribution lines. Tall towers carry conductors that leap across mountains and seas, stretching into the distance before reaching cities and villages. This is also an interesting topic—today, let's explore transmission lines and their supporting towers.Power Transmission and DistributionFirst, let’s understand how electricity is delivered. The electric power industry primarily consists of fou
Encyclopedia
10/21/2025
Automatic Reclosing Modes: Single, Three-Phase & Composite
Automatic Reclosing Modes: Single, Three-Phase & Composite
General Overview of Automatic Reclosing ModesTypically, automatic reclosing devices are categorized into four modes: single-phase reclosing, three-phase reclosing, composite reclosing, and disabled reclosing. The appropriate mode can be selected based on load requirements and system conditions.1. Single-Phase ReclosingMost 110kV and higher transmission lines employ three-phase single-shot reclosing. According to operational experience, over 70% of short-circuit faults in high-voltage overhead li
Edwiin
10/21/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.