Signal Flow Graph of Control System

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Signal Flow Graph Definition


A signal flow graph simplifies control system diagrams by using nodes and branches instead of blocks and summing points.

 

1.jpeg


Rules for Drawing Signal Flow Graph


  • The signal always travels along the branch towards the direction of indicated arrow in the branch.



  • The output signal of the branch is the product of transmittance and input signal of that branch.



  • Input signal at a node is summation of all the signals entering at that node.



  • Signals propagate through all the branches, leaving a node.

 

2.jpeg

 22.jpeg

Simple Process of Calculating Expression of Transfer Function for Signal Flow Graph


  • First, calculate the input signal at each node of the graph. This is done by summing the products of transmittance and the variables at the other ends of branches pointing to the node.



  • Now by calculating input signal at all nodes will get numbers of equations which relating node variables and transmittance. More precisely, there will be one unique equation for each of the input variable node.



  • By solving these equations we get, ultimate input and output of the entire signal flow graph of control system.



  • Lastly by dividing inspiration of ultimate output to the expression of initial input we calculate the expiration of transfer function of that signal flow graph

 

3.jpeg

 

33.jpeg

 333.jpeg

3333.jpeg

If P is the forward path transmittance between extreme input and output of a signal flow graph. L1, L2…………………. loop transmittance of first, second,.….. loop of the graph. Then for first signal flow graph of control system, the overall transmittance between extreme input and output is


For the second signal flow graph of a control system, the overall transmittance between the input and output is calculated similarly.


Here in the figure above, there are two parallel forward paths. Hence, overall transmittance of that signal flow graph of control system will be simple arithmetic sum of forward transmittance of these two parallel paths.

 

4.jpeg

 41.jpeg

As the each of the parallel paths having one loop associated with it, the forward transmittances of these parallel paths are


Therefore overall transmittance of the signal flow graph is

 

5.jpeg

 

Mason’s Gain Formula

 

6.jpeg

 61.jpeg

The overall transmittance or gain of a signal flow graph in a control system is given by Mason’s Gain Formula.


7.jpeg

 


Where, P k is the forward path transmittance of kth in path from a specified input is known to an output node. In arresting Pk no node should be encountered more than once.


Δ is the graph determinant which involves closed loop transmittance and mutual interactions between non-touching loops.


Δ = 1 – (sum of all individual loop transmittances) + (sum of loop transmittance products of all possible pair of non-touching loops) – (sum of loop transmittance products of all possible triplets of non-touching loops) + (……) – (……)


Δ k is the factor associated with the concerned path and involves all closed loop in the graph which are isolated from the forward path under consideration.


The path factor Δk for the kth path is equal to the value of grab determinant of its signal flow graph which exist after erasing the Kth path from the graph.


By using this formula one can easily determine the overall transfer function of control system by converting a block diagram of control system (if given in that form) to its equivalent signal flow graph. Let us illustrate the below given block diagram.

 

f32efc5ef88df75627102583bab18e70.jpeg

bcb4ee31e71500a1be0ecb5e9a298245.jpeg



35a0a09b2c6b76c955ef429d9b82ea5b.jpeg

Give a tip and encourage the author!
Recommended
Three-Phase SPD: Types, Wiring & Maintenance Guide
Three-Phase SPD: Types, Wiring & Maintenance Guide
1. What Is a Three-Phase Power Surge Protective Device (SPD)?A three-phase power surge protective device (SPD), also known as a three-phase lightning arrester, is specifically designed for three-phase AC power systems. Its primary function is to limit transient overvoltages caused by lightning strikes or switching operations in the power grid, thereby protecting downstream electrical equipment from damage. The SPD operates based on energy absorption and dissipation: when an overvoltage event occ
James
12/02/2025
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Railway power systems primarily consist of automatic block signaling lines, through-feeder power lines, railway substations and distribution stations, and incoming power supply lines. They provide electricity to critical railway operations—including signaling, communications, rolling stock systems, station passenger handling, and maintenance facilities. As an integral part of the national power grid, railway power systems exhibit distinct characteristics of both electrical power engineering and
Echo
11/26/2025
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.