Digital Data of Control System

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

Digital Data Of A Control System

In the present article we will discuss all about discrete signals which are made up of discrete data or sampled data or also known as digital data of control system. Now before we discuss this topic in detail it is very essential to know, what is the need of a digital technology though we have analog systems?
So let us discuss first some advantages of digital system over analog system.

  1. Power consumption is less in digital system as compared to analog system.

  2. Digital systems can handle non linear system easily which is the most important advantage of digital data in control system.

  3. Digital systems works on the logical operations due to this they show decision making property which is very useful in the present world of machines.

  4. They are more reliable as compared to analog systems.

  5. Digital systems are easily available in compact size and have light weight.

  6. They works on instructions we can program them as per our needs hence we can they are more versatile than analog systems.

  7. Various complex tasks can be performed easily by the help of digital technology with a high degree of accuracy.

Suppose you have a continuous signal then how will you convert this continuous signal into discrete signals? Answer to this question is very simple by the help of sampling process.

Sampling Process

Sampling process is defined as the conversion of analog signal into the digital signal with the help of a switch (also known as sampler). A sampler is a continuous ON and OFF switch which directly converts analog signals into digital signals. We may have a series connection of sampler depending upon the conversion of signals we use them. For an ideal sampler, the width of the output pulse is very small (tending to zero). Now when talk about discrete system it is very important to know about the z transformations. We will discuss here about the z transformations and its utilities in discrete system. Role of z transformation in discrete systems is same as Fourier transform in continuous systems. Now let us discuss z transformation in detail.
We define z transform as


Where, F(k) is a discrete data
Z is a complex number
F (z) is Fourier transform of f (k).

Important Properties of z transformation are written below
Linearity
Let us consider summation of two discrete functions f (k) and g (k) such that


such that p and q are constants, now on taking the Laplace transform we have by property of linearity:


Change of Scale: let us consider a function f(k), on taking the z transform we have


then we have by change of scale property

Shifting Property: As per this property


Now let us discuss some important z transforms and I will suggest readers to learn these transforms:


Laplace transformation of this function is 1/s2 and the corresponding f(k) = kT. Now the z transformation of this function is


Function f (t) = t2: Laplace transformation of this function is 2/s3 and the corresponding f(k) = kT. Now the z transformation of this function is



Laplace transformation of this function is 1/(s + a) and the corresponding f(k) = e(-akT). Now the z transformation of this function is


Laplace transformation of this function is 1/(s + a)2 and the corresponding f(k) = Te-akT. Now the z transformation of this function is


Laplace transformation of this function is a/(s2 + a2) and the corresponding f(k) = sin(akT). Now the z transformation of this function is


Laplace transformation of this function is s/(s2 + a2) and the corresponding f(k) = cos(akT). Now the z transformation of this function is


Now sometime there is a need to sample data again, which means converting discrete data into continuous form. We can convert digital data of control system into continuous form by hold circuits which are discussed below:

Hold Circuits: These are the circuits which converts discrete data into continuous data or original data. Now there are two types of Hold circuits and they are explained in detail:

Zero Order Hold Circuit
The block diagram representation of the zero order hold circuit is given below:
Figure related to zero order hold.
In the block diagram we have given an input f(t) to the circuit, when we allow input signal to pass through this circuit it reconverts the input signal into continuous one. The output of the zero order hold circuit is shown below.
Now we are interested in finding out the transfer function of the zero order hold circuit. On writing the output equation we have


on taking the Laplace transform of the above equation we have


From the above equation we can calculate transfer function as


On substituting s=jω we can draw the bode plot for the zero order hold circuit. The electrical representation of the zero order hold circuit is shown below, which consists of a sampler connected in series with a resistor and this combination is connected with a parallel combination of resistor and capacitor.

zero order hold circuitgain plot

GAIN PLOT – frequency response curve of ZOH

phase plot

PHASE PLOT – frequency response curve of ZOH

First Order Hold Circuit
The block diagram representation of the first order hold circuit is given below:

first order hold circuit

First Order Hold Circuit

In the block diagram we have given an input f(t) to the circuit, when we allow input signal to pass through this circuit it reconverts the input signal into continuous one. The output of the first order hold circuit is shown below: Now we are interested in finding out the transfer function of the first order hold circuit. On writing the output equation we have


On taking the Laplace transform of the above equation we have


From the above equation we can calculate transfer function as (1-e-sT)/s. on substituting s=jω we can draw the bode plot for the zero order hold circuit. The bode plot for the first order hold circuit is shown below which consists of a magnitude plot and a phase angle plot.The magnitude plot starts with magnitude value 2π/ωs.

gain plot

Gain Plot of First Order Hold Circuit

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.