Dual Network Circuit Analysis

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What is a Dual Network?

Two electrical networks are said to be dual networks if the mesh equations of one network is equal to the node equation of the other.

The dual network is based on Kirchhoff Current Law and Kirchhoff Voltage Law.



electric mesh network



Applying Kirchhoff Voltage Law in the network A, above we get,







electric node network



Applying Kirchhoff Current Law in the network B, above we get,





Here we have found that equations (i) and (ii) are similar in their mathematical form. Equation (i) is in mesh form and equation (ii) is in nodal form.

Here, the left side variable of equation (i) is voltage, and the left side variable of equation (ii) is current.

Similarly, the right side of equation (i) is a product of the current and total impedance of the circuit.

Similarly, the right side of equation (ii) is the product of voltage and admittance of the circuit.

So, it is needless to say these two networks are dual networks. From, the examples it is also clear that dual networks may not be equivalent networks.

The circuit equation of the two dual networks are similar in form but the variable is interchanged.

Construction of a Dual Network

Let us consider the series RLC circuit as shown below.



series rlc circuit



Applying Kirchhoff Voltage Law in this circuit, we get,





Let us replace all the variables and constants by their dual in the equation. By doing that, we get,





The electrical network drawn by the circuit equation (iv), would be



parallel rlc circuit







Hence:





This is nothing but Kirchhoff’s Current Law. As per the definition of a dual network, network C and network D are dual to each other.

Table of Dual Elements


Element Element
Electrical resistance Conductance
Inductance Capacitance
Service Branch Parallel Branch
Switch Closed Switch Open
Charge Flux Linkage
Mesh Node

Source: Electrical4u.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.



Give a tip and encourage the author!
Recommended
What Is the Current Status and Detection Methods of Single-Phase Grounding Faults?
What Is the Current Status and Detection Methods of Single-Phase Grounding Faults?
Current Status of Single-Phase Grounding Fault DetectionThe low accuracy of single-phase grounding fault diagnosis in non-effectively grounded systems is attributed to several factors: the variable structure of distribution networks (such as looped and open-loop configurations), diverse system grounding modes (including ungrounded, arc-suppression coil grounded, and low-resistance grounded systems), the increasing annual ratio of cable-based or hybrid overhead-cable wiring, and complex fault typ
Leon
08/01/2025
Frequency division method for measuring grid-to-ground insulation parameters
Frequency division method for measuring grid-to-ground insulation parameters
The frequency division method enables the measurement of grid-to-ground parameters by injecting a current signal of a different frequency into the open delta side of the potential transformer (PT).This method is applicable to ungrounded systems; however, when measuring the grid-to-ground parameters of a system where the neutral point is grounded via an arc suppression coil, the arc suppression coil must be disconnected from operation beforehand. Its measurement principle is shown in Figure 1.As
Leon
07/25/2025
Tuning Method for Measuring Ground Parameters of Arc Suppression Coil Grounded Systems
Tuning Method for Measuring Ground Parameters of Arc Suppression Coil Grounded Systems
The tuning method is suitable for measuring the ground parameters of systems where the neutral point is grounded via an arc suppression coil, but not applicable to ungrounded neutral point systems. Its measurement principle involves injecting a current signal with continuously varying frequency from the secondary side of the Potential Transformer (PT), measuring the returned voltage signal, and identifying the system's resonant frequency.During the frequency sweeping process, each injected heter
Leon
07/25/2025
Impact of Grounding Resistance on Zero-Sequence Voltage Rise in Different Grounding Systems
Impact of Grounding Resistance on Zero-Sequence Voltage Rise in Different Grounding Systems
In an arc - suppression coil grounding system, the rising speed of the zero - sequence voltage is greatly affected by the value of the transition resistance at the grounding point. The larger the transition resistance at the grounding point, the slower the rising speed of the zero - sequence voltage.In an ungrounded system, the transition resistance at the grounding point has basically no impact on the rising speed of the zero - sequence voltage.Simulation Analysis: Arc - suppression Coil Ground
Leon
07/24/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.