Anderson′s Bridge | Advantages Disadvantages of Anderson′s Bridge

Electrical4u
Field: Basic Electrical
0
China

What Is Anderson′s Bridge

Anderson’s Bridge

Let us understand why there is a need for Anderson’s bridge though we have Maxwell bridge and Hay’s bridge to measure the quality factor of the circuit. The main disadvantage of using Hay’s bridge and Maxwell bridge is that they are unsuitable for measuring the low-quality factor.

However, Hay’s bridge and Maxwell bridge are suitable for measuring accurately high and medium quality factors respectively. So, there is need of bridge which can measure low-quality factor and this bridge is modified Maxwell’s bridge and known as Anderson’s bridge.

Actually, this bridge is the modified Maxwell inductor capacitance bridge. In this bridge double balance can be obtained by fixing the value of capacitance and changing the value of electrical resistance only.

It is well known for its accuracy of measuring inductors from a few micro Henry to several Henry. The unknown value of the self inductor is measured by the method of comparison of the known value of electrical resistance and capacitance. Let us consider the actual circuit diagram of Anderson’s bridge (see figure given below).
andersons bridge

In this circuit, the unknown inductor is connected between the point a and b with electrical resistance r1 (which is pure resistive).

The arms bc, cd and da consist of resistances r3, r4 and r2 respectively which are purely resistive. A standard capacitor is connected in series with variable electrical resistance r and this combination is connected in parallel with cd.

A supply is connected between b and e.
Now let us derive the expression for l1 and r1:

At the balance point, we have the following relations that hold good and they are:

Now equating voltages drops we get,

Putting the value of ic in the above equations, we get


The above equation (7) obtained is more complex than we have obtained in the Maxwell bridge. On observing the above equations we can easily say that to obtain convergence of balance more easily, one should make alternate adjustments of r1 and r in Anderson’s bridge.

Now let us look at how we can obtain the value of unknown inductors experimentally. At first set the signal generator frequency at audible range. Now adjust r1 and r such that the phones give a minimum sound.

Measure the values of r1 and r (obtained after these adjustments) with the help of a multimeter. Use the formula that we have derived above in order to find out the value of unknown inductance. The experiment can be repeated with the different values of the standard capacitor.

Phasor Diagram of Anderson’s Bridge

Let us mark the voltage drops across ab, bc, cd, and ad as e1, e2, e3 and e4 as shown in the figure above.
phasor of andersons bridge
Here in the phasor diagram of Anderson’s bridge, we have taken i1 as the reference axis. Now ic is perpendicular to i1 as the capacitive load is connected at ec, i4 and i2 are lead by some angle as shown in the figure.

Now the sum of all the resultant voltage drops i.e. e1, e2, e3, and e4 is equal to e, which is shown in phasor diagram. As shown in the phasor diagram of Anderson’s bridge the resultant of voltages drop i1 (R1 + r1) and i1.ω.l1 (which is shown perpendicular to i1) is e1. e2 is given by i2.r2 which makes angle ‘A’ with the reference axis.

Similarly, e4 can be obtained by voltage drop i4.r4 which is making angle ‘B’ with the reference axis.

Advantages of Anderson’s Bridge

  1. It is very easy to obtain the balance point in Anderson’s bridge as compared to Maxwell bridge in the case of low-quality factor coils.

  2. There is no need for a variable standard capacitor is required instead of thin a fixed value capacitor is used.

  3. This bridge also gives accurate results for the determination of capacitance in terms of inductance.

Disadvantages of Anderson’s Bridge

  1. The equations obtained for the inductor in this bridge are more complex as compared to Maxwell’s bridge.

  2. The addition of capacitor junction increases complexity as well as the difficulty of shielding the bridge.

Considering above all the advantages and disadvantages, the Maxwell bridge is preferred over Anderson’s bridge whenever the use of a variable capacitor is permissible.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
HECI GCB for Generators – Fast SF6 Circuit Breaker
1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
01/06/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.