• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Double-Spin Robot

  • Double-Spin Robot
  • Double-Spin Robot
  • Double-Spin Robot
  • Double-Spin Robot
  • Double-Spin Robot

Key attributes

Brand Wone Store
Model NO. Double-Spin Robot
Rated Load Capacity 16kg
degree of freedom 6-direction
Maximum working stroke 1600mm
Series BR

Product descriptions from the supplier

Description

BR series double-spin robot, the first domestic double-spin mode and structure, is a model for domestic industrial robots to build core competitiveness through innovation. According to the market characteristics of domestic 3C industry roughneck center, stamping robots are mostly used for small pieces of high-speed stamping. In order to meet the needs of such applications, a vertical multi-joint high-speed robot is specially developed, and the concept of double rotation is proposed for the first time, which can not only realize all the functions (external rotation) of a standard general six-axis robot, but also rotate from within itself (internal rotation).

Key features:

  • Independent double-spin structure

    The five-axis wrist assembly adopts bevel gear transmission to realize the external bias of the six-axis end joint assembly relative to the small arm assembly, and the sixth axis cable passes out from the wrist joint and is supported by the cable bracket into the six-axis end joint, thus realizing the five-axis large-scale movement over the line.

  • Design of Large Range Motion Over-line

    The five-axis wrist assembly adopts bevel gear transmission to realize the external bias of the six-axis end joint assembly relative to the small arm assembly, and the sixth axis cable passes out from the wrist joint and is supported by the cable bracket into the six-axis end joint, thus realizing the five-axis large-scale movement over the line.

  • Small footprint design

    The internal rotating structure is specially designed for CNC high-speed driller center and fast punching machine, which can easily realize the connection or handling between stations in a narrow space within 800 of the spacing between driller centers, easily avoiding and with the fastest speed. Stamping application station handling covers only the base area.

  • multiple perception

    BR double-rotation robot has a multi-dimensional sensor with multi-modal perception of the safety of industrial robots, but also added intelligent language interaction, drag teaching, safety monitoring and other functions, to achieve a human and robot, the environment between the communal interaction, while industrial robots with high speed, high precision, high load, strong reliability characteristics.


Technology Parameters

Industrial robots BR610-1300 BR612-1100 BR616-1600 BR625-1900
Degrees of freedom 6 6 6 6
Maximum load 10kg 12Kg 16Kg 25kg
Maximum working radius 1310mm 1100mm 1600mm 1849.5
Repeat positioning accuracy ±0.05 mm ±0.05mm ±0.05mm ±0.05mm
Range of motion J1 ±155° ±155° ±154° ±155°
J2 -178° / -2° -178°/-2° -178°/-2° 178°/- 2°
J3 +120°/+420° +120°/+420° +103°/+437° +128°/ +412°
J4 ±190° ±360° ±360° ±360°
J5 ±165° ±161° ±161° ±131°
J6 ±360° ±360° ±360° ±360°
Maximum speed J1 360°/s, 6.28 rad/s 360°/s,6.28rad/s 236°/s,4.12rad/s 233°/ 4.06 rad/s
J2 250°/s, 4.36 rad/s 250°/s,4.36 rad/s 217°/s,3.78 rad/s 235°/ 4.10 rad/s
J3 360°/s, 6.28 rad/s 360°/s,6.28rad/s 357°/s,6.23rad/s 285°/ 4.97 rad/s
J4 480°/s, 8.38 rad/s 480°/s,8.38 rad/s 443°/s,7.72 rad/s 487°/ 8.49 rad/s
J5 360°/s, 6.28 rad/s 360°/s,6.28 rad/s 360°/s,6.28 rad/s 487°/ 8.49 rad/s
J6 450°/s, 7.85 rad/s 450°/s,7.85 rad/s 450°/s,7.85 rad/s 487°/ 8.49 rad/s
Allowing for the moment of inertia J6 0.39 kgm3 0.52kgm3 0.26kgm3 1.43 kgm3
J5 0.42 kgm3 1.5kgm3 1.2kgm3 2.65 kgm3
J4 0.42 kgm3 1.1kgm3 1.04kgm3 2.42 kgm3
Allowable Torque J6 14Nm 20.3Nm 14.4Nm 38.7Nm
J5 20.4Nm 42Nm 43Nm 77.5Nm
J4 20.4Nm 36Nm 40Nm 57.5Nm
Applicable Environment Temperature 0°C to 45°C 0°C to 45°C 0°C to 45°C 0°C to 45°C
Humidity 20% to 80% 20%~80% 20%~80% 20% to 80%
Other Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma). Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma). Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma). Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma).
Teaching device cable length 8m 8m 8m 8m
Body-to-cabinet connection cable length 3m 6m 6m 6m
I/O parameters Digital inputs: 32-bit (NPN), 32-bit outputs (NPN) Digital inputs: 32-bit (NPN), 32-bit outputs (NPN) Digital inputs: 32-bit (NPN), 32-bit outputs (NPN) 32 - bit input (PNP), 30 - bit output (NPN)
Body-prepared signal cable 12-pin (connected via aviation connector) 12-pin (connected via aviation connector) 12-pin (connected via aviation connector) 24 - bit (connected via aviation connector)
Reserved air circuit 1xφ6 1xφ8 1xφ8 2xφ8
Power capacity 2.55kVA 2.8kVA 2.8kVA 6.5kVA
Rated power/voltage/current 2.04 kW / Single-phase AC 220V / 11.6 A 2.23kW/single-phaseAC220V /12.1A 2.69kW/single-phaseAC220V /15.3A 5.2kW / 3 phase / 380V / 10A
Enclosure/Electrical Cabinet Protection Rating IP54 (arm IP67) / IP53 IP54 (arm IP67) / IP53 IP54 (arm IP67) / IP54 IP54 (front -end IP67)/ IP53 
Installation method Ground, inverted, and side-mounted installations Ground, inverted, and side-mounted installations Ground, inverted, and side-mounted installations Ground, inverted, and side-mounted installations
Body/Electrical Cabinet Weight 61kg/15kg 65kg/15kg 12.4kg/47kg 210kg/66kg

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.