• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Hollow Wrist Robot

  • Hollow Wrist Robot
  • Hollow Wrist Robot
  • Hollow Wrist Robot

Key attributes

Brand Wone Store
Model NO. Hollow Wrist Robot
Rated Load Capacity 20kg
degree of freedom 6-direction
Maximum working stroke 1850mm
Series JH

Product descriptions from the supplier

Description

The large hollow wrist robot developed by JH Series Robot is a new breakthrough in product research and development technology for many years. It is superior to regular general-purpose products in terms of ease of use and coverage width of application scenarios, and has the unique advantages of large hollow, high speed and high precision.

Key features:

1. High rigidity: 40% higher rigidity compared to the previous generation, delivering improved stability and outstanding performance in reducing operational vibration.

2. High Speed: By incorporating a higher-speed motor and a superior-performing gearbox, we achieve faster cycle times and enhanced operational efficiency.

3. High Precision: The new-generation welding robot achieves a repeat positioning accuracy of up to ±0.05mm, with trajectory accuracy and repeatability—along with other precision metrics—showing a 20% improvement over the previous generation.

4. Excellent Reach: The working radius reaches up to 2000 mm, with each axis offering a significantly improved range of motion compared to the previous generation—resulting in overall enhanced accessibility.

5. Practicality: With a smaller wrist size, it significantly enhances the convenience of teaching demonstrations. The hollow structure allows for the use of a hollow welding torch.

6. Strong Anti-Interference Capability: The robot features a completely new anti-interference structure, significantly enhancing its ability to withstand external disturbances.

Technology Parameters

Industrial robots JH605-1500 JH615-2000 JH620-1800
Degrees of freedom 6 6 6
Maximum load 5kg 15kg 20kg
Maximum working radius 1494mm 2000mm 1800mm
Repeat positioning accuracy ±0.05 m ±0.05 mm ±0.05 mm
Range of motion J1 ±170° ±165° ±165°
J2 -175°/+60° -165°/+75° -165°/+75°
J3 +6° / +270° -15°/ +260° -15°/ +260°
J4 ±180° ±170° ±170°
J5 -120° / +150° ±140° ±140°
J6 ±360° ±400° ±400°
Maximum speed J1 225°/s, 3.92 rad/s 220°/s, 3.84 rad/s 220°/s, 3.84 rad/s
J2 225°/s, 3.92 rad/s 205°/s, 3.58 rad/s 205°/s, 3.58 rad/s
J3 252°/s, 4.40 rad/s 220°/s, 3.84 rad/s 220°/s, 3.84 rad/s
J4 407°/s, 7.10 rad/s 330°/s, 5.76 rad/s 330°/s, 5.76 rad/s
J5 600°/s, 10.47 rad/s 420°/s, 7.33 rad/s 420°/s, 7.33 rad/s
J6 927°/s, 16.18 rad/s 670°/s, 11.7 rad/s 670°/s, 11.7 rad/s
Allowing the moment of inertia J6 0.2 kgm3 2.8 kgm3 2.8 kgm3
J5 0.4 kgm3 2.2 kgm3 2.2 kgm3
J4 0.4 kgm3 1 kgm3 1 kgm3
Allowable Torque J6 6.5Nm 60Nm 60Nm
J5 12Nm 52Nm 52Nm
J4 12Nm 32Nm 32Nm
Applicable Environment Temperature 0°C to 45°C 0°C to 45°C 0°C to 45°C
Humidity 20% to 80% 20% to 80% 20% to 80%
Other Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma). Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma). Avoid contact with flammable, explosive, or corrosive gases and liquids, and keep away from sources of electronic noise (such as plasma).
Teaching device cable length 8m 8m 8m
Body-to-cabinet connection cable length 5m 5m 5m
I/O parameters Digital inputs: 32-bit (NPN), 32-bit outputs (NPN) Digital quantities: 32-bit input, 31-bit output Digital quantities: 32-bit input, 31-bit output
Body-prepared signal cable 24-bit, 4-bit (wiring method for aviation connector: soldering) 24-bit 24-bit
Reserved air circuit 1xφ8 3xφ8 3xφ8
Power capacity 4.5kVA 6.9kVA 6.9kVA
Rated Power 3.6kW 5kW 5kW
Rated Voltage Single-phase AC 220V Three-phase 380V Three-phase 380V
Rated current 19A 9.3A 9.3A
Intrusion Protection Rating IP54 IP54 (arm IP67) IP54 (arm IP67)
Installation method Ground, inverted, and side-mounted installations Ground, inverted, and side-mounted installations Ground, inverted, and side-mounted installations
Body weight 185kg 285kg 280kg
Protection rating of control cabinets IP20 IP54 IP54
Control cabinet weight 15kg 28kg 28kg

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.