Zer Nahi Ditzakegun Kargu Aldaketako Akastunenari Buruz

Master Electrician
Master Electrician
Eremua: Elektrizitate Oinarrizko
0
China

Hola, naiz Blue — eletrikari gisa lan egin dut orain bitartean 20 urte gehiago.

Beharrik asko nekazaritza eginda naut, transformatzaileak kudeatuta eta elektrizitate-sistema desberdinetako arazo guztiak ebazta.

WechatIMG3584.png

Gaur, Aipuren bat aske nagusi hemen:

"Zer dira karga-itzulagailuen oinarrizko akatsak?"

Pertsonatu galdera! Beraz, azalduko dugu errazki — ez jargoni tekniko bana, baita lanpean edo mantentzeetan ikus daitezkeen zerbait bakarrik.

Lehenik, Zer Da Karga-Itzulagailua?

Arazoak hitz aurretik, karga-itzulagailuaren definizioa errepasatzeko.

Karga-itzulagailu bat 10kV, 20kV sareen kalibreko sistemaen erabilera bereizi bat da. Arrunta duen korrontea itxi eta ireki dezake, baina ez faltsu-korrontea — horretarako daitzelako nekazariak.

Beraz, irudikatu beharko luke "erdian" dagoena arrunta den itzulagailuaren eta nekazari osokoaren artean. Sinpleagoa, gutxiago kostatzen duena, eta erabiltzen da banaketa sareetan, batez ere, protekzio-konbinazioak ez diren oso konplexuak dituzten lekuetan.

Orain, Hitza Emango Dugu Oinarrizko Akatsengatik

Nire urte askotan lanpean eta arazoak ebaztean, hauetako arazoak berriro eta berriro ikusi ditut. Hona hemen oinarrizkoen zerrenda:

1. Ezin da Itxi edo Iritsi Moduan Egoki

Hau oso ohikoa da, batez ere zaharragoen gailuetan.

Sometimes the switch won’t close even when you press the button.

Edo itxita dago, baina ondoren irekitzen da beti.

Ezinezkoa izan daiteke irekitzeko, itxita utzi.

Zergatik gertatzen da hau?

Mekanismoen pieza asko erosita egiten dira denbora luzean — lotura blokeatuta, muelleak ahultsua, kolpetxoak desaliniatu.

Kontrol-zirkuituetan amarren hilak edo relei hogei egon daitezke.

Askotan motorra (elektrikoki erabiltzen bada) huts egiten du.

Adibide erreala:

Batzuei lan egin nien non karga-itzulagailua ez zion itxi txiki bat erori mekanismoan eta mugimendua blokeatuta zuen. Bi ordu hartu ziguten aurkitzeko!

2. Sorginak edo Odol Barreiluak

Karga-itzulagailu panel baten inguruan odol barreilu bat sentitzen baduzu, ez utzi.

Sorgina kontaktuen edo terminalen konexioetan gertatzen da.

Ez zabaldu insulazioa, pieza batzuk babestu, edo belar bat sortu dezake ez zabaldu aurrekontuan.

Zergatik gertatzen da hau?

Kableen konexioen oinarria — gorputza handia = sorgina.

Kontaktuak zaharrak edo poltunak — kontaktu-surface okerra.

Korronte handia erdiuneko kapasitatea gaindituta (gainkorapena).

Aholku: Egin ezazu tenperatura eguneroko kontrola infrarojo termografia erabiliz. Konexio bat beste bakoitzetatik 10–15°C gorria badago, ikerketa ASKATU.

3. Arkadura edo Flashover Operazioan

Entzun duzu hautsa handia, agian isurtza bat — horixe arkadura da.

Gertatzen da askotan irekitzea/itzean.

Arriskutsua, pieza batzuk zeharka egin dezakete edo gaixotasuna ekarri.

Oinarrizko arrazoia:

Kontaktu nagusiak erosita — tartea ez da mantentzen moduan egokia.

Dust edo moisture inside the chamber — lowers insulation level.

Operating under load when it shouldn’t be (e.g., switching off a large motor without a circuit breaker upstream).

Note: Load switches are not meant to interrupt fault currents, only normal load currents. If you’re trying to cut through a short-circuit current, expect trouble.

4. Mekanismoen Erosioa eta Errosioa

Karga-itzulagailuak mekanismo gisa dira. Mugitzen direnean, azkar erosita egiten dira.

Laguntzaileak, errotoreak eta palankak denbora luzean degradatzen dira.

Bereizki, itsaso-ume, edo tenperatura arrazoi uneetan oso egia da.

Aholku: Mantentza preventiboa (PM) erregularrak garrantzitsua da. Lubrifikatu pieza mugigarriz, ikusi lotura, eta ordeztu erosita direnak huts egin baino lehen.

5. Kontrol-Zirkuituen Akatsak

Kontrol aldea main circuitaren bezala garrantzitsu da.

Indikadore-luzerak ez dute funtzionatzen.

Remote operation fails.

Local buttons don’t respond.

Typical causes:

Blown fuses in the control circuit.

Corroded terminals or broken wires.

PLC or RTU communication errors (in automated systems).

Quick fix idea: Use a multimeter to trace voltage drop and continuity. Start simple — check fuses first.

6. Moisture and Corrosion Inside the Enclosure

Especially common in coastal areas or humid climates.

Moisture gets into the switchgear cabinet.

Causes rust, corrosion, and reduced insulation levels.

Symptoms:

Tripping for no apparent reason.

Arcing even under light load.

Bad smell or condensation visible inside the box.

Solution: Make sure the enclosure has proper sealing and desiccant packs. In tropical areas, consider adding space heaters or dehumidifiers.

7. Wrong Operation by Personnel

Human error is still one of the biggest causes of failures.

Someone tries to open the switch under heavy load.

Or operates the switch without checking interlocks.

Even worse — someone forgets to lock out/tag out before maintenance.

Lesson learned: Training matters. Clear labeling helps. And always follow safety procedures.

Final Thoughts

Like any electrical equipment, load switches aren’t perfect. But with good design, regular maintenance, and proper operation, most of these faults can be avoided or caught early.

As someone who’s been in the field for over two decades, my advice is:

“Don’t wait for a failure to remind you that maintenance is important.”

If you're dealing with a faulty load switch and want help troubleshooting or choosing replacements, feel free to reach out. Happy to share more stories (and some war scars) from the field.

Stay safe, and keep the lights on!

— Blue


Ordaintza ematea eta egilea bermatzea
Gomendioa
10kV RMU ohiko arazoak & soluzioen gidamurua
10kV RMU ohiko arazoak & soluzioen gidamurua
Aplikazio Arazoak eta Kudeaketako Arrazoiak 10kV Erloju Unitate Entzukabeen (RMU) Entzun10kV erloju unitate entzukabea (RMU) hiriko energia banaketa sareetan oso ohikoa den tresna elektrikoa da, berehala erabilgarri dagoen tenperatura altuaren energia banaketarako. Eguneroko erabilitasunean, zenbait arazo agertu daitezke. Hemen daude arrakasta eta zuzendaritza neurriak.I. Elektrizitateko Akatsak Barneko Itsasaldi Laburra edo Konexio TxarraItsasaldi laburra edo konexio txarra RMUn barnean ekintza
Echo
10/20/2025
Mugimendu Krokis Iribarreko Mota eta Akatsen Gida
Mugimendu Krokis Iribarreko Mota eta Akatsen Gida
Tension handia dutzien kontsultoreak: Klasifikazioa eta Akatsen DiagnostikaTension handia dutzien kontsultoreak dira sistema elektrikoetan elementu garrantzitsuak. Akats bat gertatzen denean, korrontea azkar itzaltzen dute, maquinariaren zauriketa kargu handietatik edo zirkuitu laburraetatik saihesteko. Hala ere, lan luze eta beste faktoreengatik, kontsultoreek akatsak garatu ditzazkete, eta orduan diagnostikoa eta arazoak konpondu behar dira.I. Tension handia dutzien kontsultoreen Klasifikazioa
Felix Spark
10/20/2025
10 Kointzak Trasformadoreen Instalazio eta Eragitzeentzat!
10 Kointzak Trasformadoreen Instalazio eta Eragitzeentzat!
10 Ariketa Trasformatorren Instalazio eta Erabilera! Inoiz ez instalatu trasformatoria hain urrun—ez erabili mendietan edo zabal-zaharrean. Distantzia handia kableak desapurtzen ditu, lerroko galderak handitzen ditu eta kudeaketa eta mantentzea oso zaila bihurtzen da. Ez aukeratu trasformatoraren kapasitatea arbitrarioki. Kapasitate egokia aukeratzea oso garrantzitsua da. Kapasitate txikia izateak trasformatoria sobrecargatzen du eta arriskutzat jartzen da—sobrecarga 30% baino gehiagokoak ezin d
James
10/20/2025
Nola mantentzeko Trasformadore Elektrokimikoak Seguruki?
Nola mantentzeko Trasformadore Elektrokimikoak Seguruki?
Txertxien erresistentzi gutxiak mantentzearen prozedurak Jarri txertxiera ordezko lanera, ireki txertxiera mantentzeko batera-tentsioaren iturri-kontrolatzailea, kendu kontrolatzeko indarra duen fusia eta egin "EZ IREKI" adierazpen bat iturri-kontrolatzailearen mandoan. Ireki txertxiera mantentzeko altu-tentsioaren iturri-kontrolatzailea, itxi lurreko iturri-kontrolatzailea, deskargatu txertxiera osotsik, blokeatu altu-tentsioaren arkuila eta egin "EZ IREKI" adierazpen bat iturri-kontrolatzailea
Felix Spark
10/20/2025
Eskaera bidali
Jeitsi