Starting of an Induction Motor

05/07/2025

Three - Phase Induction Motors: Self - Starting Mechanism and Starting Methods
A three - phase induction motor is inherently self - starting. When the power supply is connected to the stator of a three - phase induction motor, a rotating magnetic field is generated. This rotating magnetic field interacts with the rotor, causing it to start rotating and initiating the operation of the induction motor. At the moment of starting, the motor slip is equal to 1, and the starting current is significantly high.
The role of a starter in a three - phase induction motor extends beyond mere starting. It serves two primary functions:
  1. Current Limitation: It reduces the substantial starting current, which, if left unchecked, could cause damage to the motor windings, overheat electrical components, and create voltage drops in the supply system.
  2. Protection: It provides essential safeguards against overloads, which occur when the motor draws excessive current due to mechanical stress or abnormal operating conditions, and under - voltage situations, where a drop in supply voltage could lead to inefficient motor operation or even stalling.
There are two fundamental approaches to starting a three - phase induction motor. One method involves connecting the motor directly to the full supply voltage. The other approach entails applying a reduced voltage to the motor at startup. It's important to note that the torque produced by an induction motor is proportional to the square of the applied voltage. Consequently, a motor generates significantly more torque when started at full voltage compared to when it is started with reduced voltage.
For cage induction motors, which are widely used in industrial and commercial applications, there are three main starting methods:
Starting Methods for Induction Motors
Direct - on - Line Starter
The direct - on - line (DOL) starter method for induction motors is renowned for its simplicity and cost - effectiveness. With this approach, the motor is directly connected to the full supply voltage. This straightforward method is typically employed for small motors with a rating of up to 5 kW. By using a DOL starter for these smaller motors, potential fluctuations in the supply voltage can be minimized, ensuring stable operation of the electrical system.
Star - Delta Starter
The star - delta starter is one of the most common and widely adopted methods for starting three - phase induction motors. In normal operation, the motor's stator windings are configured in a delta connection. However, during the starting phase, the windings are initially connected in a star configuration. This star connection reduces the voltage applied to each winding, thereby limiting the starting current. Once the motor has gained sufficient speed, the windings are then switched to the delta connection, allowing the motor to operate at its full - rated performance.
Autotransformer Starter
Autotransformers can be used in either star - connected or delta - connected configurations. Their primary function in the context of induction motor starting is to limit the starting current. By adjusting the turns ratio of the autotransformer, the voltage supplied to the motor during startup can be reduced. This controlled reduction in voltage helps to mitigate the high inrush current that occurs when the motor is first energized, protecting both the motor and the electrical supply system.
The direct - on - line, star - delta, and autotransformer starters are specifically designed for cage rotor induction motors, which are prevalent in a wide range of industrial and commercial applications due to their robust construction and reliable operation.
Slip Ring Induction Motor Starter Method
For slip ring induction motors, the starting process involves connecting the full supply voltage across the starter. The unique design of slip ring motors, with their external rotor circuits, allows for additional control during starting. The connection diagram of a slip ring induction motor starter provides a visual representation of how the various components interact to facilitate the starting process, enabling better understanding of its operation and control mechanisms.
When starting a slip ring induction motor, the full starting resistance is initially connected in the rotor circuit. This effectively reduces the supply current drawn by the stator, minimizing the inrush current that could otherwise stress the electrical system and the motor itself. As the electrical supply energizes the motor, the rotor begins to rotate.
As the motor accelerates, the rotor resistances are systematically reduced in stages. This gradual cutting - out of the resistances is carefully coordinated with the increase in the motor's rotational speed. By doing so, the motor can smoothly build up its speed while maintaining optimal torque characteristics.
Once the motor reaches its rated full - load speed, all the starting resistances are completely removed from the circuit. At this point, the slip rings are short - circuited. This short - circuiting allows the motor to operate with maximum efficiency, as it eliminates the additional resistance that was only necessary during the starting phase, enabling the motor to deliver its full - rated performance.

Wenzhou Rockwell Transformer Co., Ltd. It is a high - tech enterprise integrating R & D, production, sales, and service. It focuses on the manufacturing of power transformers and supporting equipment, and is committed to providing efficient, reliable, and energy - saving power transmission and distribution solutions for global customers. We can offer: •Distribution transformers and substations •Outdoor switchgears and breakers(recloser) •Switchgears and it’s components (GIS, RMU, VCB, SF6 CB) Market and Service: We always take customers as the orientation and provide customized services according to their requirements. Our products are exported to the Middle East, Africa, Northern Europe, South America, and many other countries and regions. Drive the future of electricity with technological innovation and become a leading global supplier of intelligent power equipment.

What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
09/02/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high