What is a Wound Rotor Induction Motor?

Encyclopedia
Field: Encyclopedia
0
China

What is a  Wound Rotor Induction Motor?

Winding rotor induction motor definition

A wire-wound rotor induction motor (also known as a circular motor or slip-ring induction motor) is defined as a special type of three-phase AC induction motor designed to provide high starting torque by connecting an external resistance to the rotor circuit. The rotor of the motor is a winding rotor. That is why it is also called a winding rotor or phase winding induction motor.

The running speed of a slip ring induction motor is not equal to the synchronous speed of the rotor, which is why it is also called an asynchronous motor.

Winding rotor motor diagram

The stator of the winding rotor induction motor is the same as that of the squirrel-cage induction motor. The number of poles wound by the rotor of the motor is the same as the number of poles of the stator.

The rotor has three-phase insulated windings, each connected to a slip ring by a brush. The brush collects current and transfers it to and from the rotor winding.

These brushes are further connected to a three-phase star connection rheostat. The following figure shows the winding rotor induction motor diagram.

8024f992770b09838d22b702ce6ed3c2.jpeg

In a wire-wound rotor induction motor, torque is increased by adding an external resistance to the rotor circuit using a star-connected rheostat.

As the motor speed increases, the rheostat resistance is gradually cut off. This additional resistance increases the rotor impedance and therefore also reduces the rotor current.

Starting of the winding rotor induction motor

Rotor resistor/rheostat starts

Slip ring induction motors are almost always started with a full line voltage applied to the stator terminals.

The value of the starting current is adjusted by introducing a variable resistor into the rotor circuit. The control resistance is in the form of star-connected rheostat. As the motor speed increases, the resistance is gradually cut off.

By increasing the rotor resistance, the rotor current at starting is reduced, so is the stator current, but at the same time the torque is increased due to the increase in the power factor.

As mentioned earlier, the additional resistance in the rotor circuit enables the slip ring motor to produce a high starting torque at a moderate starting current.

Therefore, the winding rotor or slip ring motor can always be started under a certain load. When the motor is running under normal conditions, the slip ring shorts out and the brush is removed.

Speed control

The speed of a winding rotor or slip-ring induction motor can be controlled by changing the resistance in the rotor circuit. This method is only applicable to slip-ring induction motors.

When the motor is running, the speed of the motor is reduced if a full resistor is connected in the rotor circuit.

When the speed of the motor is reduced, more voltage is induced in the rotor circuit to produce the necessary torque, thereby increasing the torque.

Similarly, when the rotor resistance decreases, the speed of the motor increases. The figure below shows the speed-torque characteristics of a slip ring induction motor.

beba6d1bdcefd4cb706bedb98276b315.jpeg

As shown in the figure, when the rotor per phase resistance is R1, the motor speed changes to N1. The torque-speed characteristic of the motor at R is shown as the blue line.

Now, if the rotor resistance per phase increases to R2 the motor speed decreases to N2. The torque-speed characteristic of the motor at R is represented by the green line 2.

Advantages of winding rotor motor

  • High starting torque - slip ring induction motors can provide high starting torque due to the presence of external resistance in the rotor circuit.

  • High overload capacity - slip ring induction motor has high overload capacity and smooth acceleration under heavy load.

  • Low starting current compared to squirrel cage motors - additional resistance in the rotor circuit increases the rotor impedance, which reduces the starting current.

  • Adjustable speed - Speed can be adjusted by changing the resistance of the rotor circuit. Therefore, it is considered a "variable speed motor".

  • Increase power factor

Common use

Wire-wound rotor motors are used in high-power industrial applications that require high starting torque and adjustable speeds, such as cranes, lifts and elevators.

Give a tip and encourage the author!
Recommended
Transforming Power: The Future of Electric Transformers
Transformers are the "unsung heroes" of the modern world. These seemingly unremarkable devices, either hidden on utility poles or installed in substations, play an indispensable role in the power grid system—it is through them that electrical energy can be efficiently converted, transmitted, and utilized. Today, as humanity stands at the crossroads of an accelerating transformation in the energy landscape, recognizing the transformative potential of transformers and exploring how they will shape
Vziman
09/06/2025
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge