Ang isang substation nga walay grounding line selection device mihatag og single-phase grounding fault. Ang fault location system (FA) naka-identify sa fault section tali asin switch A ug switch B. Ang on-site patrol ug handling gisulod og 30 minutos aron mas isolate ang fault, walay kinahanglan og trial tripping sa non-faulty lines. Ang coordination tali asin main network ug distribution network gikinahanglan og comprehensive analysis sa "bus protection action, 3U0, three-phase voltage + line terminal alarm". Batas sa existing distribution automation equipment, walay kinahanglan og additional hardware—lamang software upgrades ang gikinahanglan. Pwede mas realize ang line selection ug section positioning pinaagi sa main-distribution network coordination.
Kapag may single-phase grounding fault, ang bus voltage sa substation naa sa grounding conditions, ug ang bus nagpadala og grounding protection signal. Sa panahon kini, ang distribution automation terminal sa switch A sa outgoing line magpadala og grounding alarm signal, apan ang switch B dili. Ang main station mag-analyze sa fault batas sa signals gikan sa main ug distribution networks, sukad nakalocate ang fault tali asin switch A ug switch B.
Ang core value sa small-current grounding line selection device makita sa accurate identification sa faulty line. Kapag may single-phase grounding fault, kini ang pinaka-importanteng tool aron direkta mohatag sa source sa problema. Ang primary significance niini mao ang quick ug accurate identification sa specific line nga may grounding fault gikan sa multiple outgoing lines.
Walay kini, ang maintenance personnel mahimong mosangpot sa time-consuming ug error-prone manual trial tripping o programmed rapid tripping—uban essentially "blind scanning". Ang pag-judge sa fault point pinaagi sa pag-cut off sa lines one by one mahimong mag-result sa unnecessary tripping sa non-faulty lines, direkta nga sacrifice sa user's power supply experience. Ang frequent short-term power interruptions dili lang mogamit sa voltage quality sa user side, apan usab adunay significant risks sa sensitive loads ( sama sa precision manufacturing ug data centers), nga kontradiktoryo sa development goals sa smart distribution networks nga gigipahanog sa high reliability ug high self-healing capabilities.
Ang automated coordinated line selection, bisan alternative, kompleks ug highly dependent sa multiple factors. Kapag walay reliance sa manual trial tripping ug walay dedicated line selection device, ang main-distribution network coordination batas sa comprehensive judgment sa "bus protection action, 3U0, three-phase voltage + line terminal alarm" usa ka feasible approach. Ang core niining scheme mao ang comprehensive use sa key fault information gikan sa substation layer ug distribution line layer para sa joint analysis.
Apan, kini gi-rely sa coordination sa multiple links: substation information collection ug transmission (hardware foundation), line terminal coverage ug reliability (data foundation), main station algorithms (core brain), ug coordination mechanisms (system linkage). Ang complexity, delay, ug success rate gi-constrain sa weakest links sa entire chain, mahimong less comparable sa dedicated devices.
Ang line selection devices dili redundant; ang accuracy niini determina kung sila usa ka "anchor of stability" o "source of accidents". Ang device nga accurate sa selection maoy core cornerstone aron mas ensure ang quick isolation ug minimize ang power outages. Apan, ang inaccurate device extremely dangerous—mahimo kini mogamit sa operation ug maintenance personnel sa pag-cut off sa healthy lines batas sa wrong information, turning "precision cutting" into a disaster that "precisely causes power outages". Thus, ang necessity niini absolutely tied sa iyang performance (accuracy, reliability), ug ang performance ang key sa iyang survival.
Bisan ang automated coordinated line selection usa ka feasible solution, ang local conditions vary across regions, ug multiple factors gi-need sa consideration. Thus, ang selection dapat gihimo batas sa local circumstances.