Electrostatic Type Instruments Construction Principle Torque Equation

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Are Electrostatic Type Instruments

Working Principle of Electrostatic Type Instruments

As the name suggests the electrostatic type instrument use static electrical field to produce the deflecting torque. These types of instrument are generally used for the measurement of high voltages but in some cases they can be used in measuring the lower voltages and powers of a given circuit. Now there are two possible ways in which the electrostatic force can act. The two possible conditions are written below,

Construction of Electrostatic Type Instruments

  • When one of the plates is fixed and other plate is free to move, plates are oppositely charged in order to have attractive force between them. Now due this attractive force movable plate will move towards the stationary or fixed plate till the moving plate stored maximum electrostatic energy.

  • In other arrangement there may be force of attraction or repulsion or both, due to some rotary of plate.

Force and Torque Equation of Electrostatic Type Instrument

Now let us derive force equation for the linear electrostatic type instruments. Let us consider two plates as shown in the diagram given below.
linear electrostatic instrument

Plate A is positively charged and plate B is negatively charged. As mentioned above as per the possible condition (a) we have linear motion between the plates. The plate A is fixed and plate B is free to move. Let us assume there exists some force F between the two plates at equilibrium when electrostatic force becomes equal to spring force. At this point, the electrostatic energy stored in the plates is

Now suppose we increase the applied voltage by an amount dV, due to this the plate B moves towards the plate A by a distance dx. The work done against the spring force due to displacement of the plate B be F.dx. The applied voltage is related to current as
From this value of electric current the input energy can be calculated as

From this we can calculate the change in the stored energy and that comes out to be
By neglecting the higher order terms that appears in the expression. Now applying the principle of energy conservation we have input energy to the system = increase in the stored energy of the system + mechanical work done by the system. From this we can write,
From the above equation the force can be calculated as
Now let us derive force and torque equation for the rotary electrostatic type instruments. Diagram is shown below,
rotary electrostatic instrumentIn order to find out the expression for deflecting torque in case of rotary type electrostatic instruments, just replace the in the equation (1) F by Td and dx by dA. Now rewriting the modified equation we have deflecting torque is equals to
Now at steady state we have controlling torque is given by the expression Tc = K × A. The deflection A can be written as
From this expression we conclude that the deflection of the pointer is directly proportional to the square of the voltage to be measured hence the scale will be non uniform. Let us now discuss about Quadrant electrometer. This instrument is generally used in measuring the voltage ranging from 100V to 20 kilo volts. Again the deflecting torque obtained in the Quadrant electrometer is directly proportional to the square of the applied voltage; one advantage of this is that this instrument can used to measure both the AC and DC voltages. One advantage of using the electrostatic type instruments as voltmeters is that we can extend the range of voltage to be measured. Now there are two ways of extending the range of this instrument. We will discuss them one by one.

(a) By using resistance potential dividers: Given below is the circuit diagram of this type of configuration.
The voltage which we want to measure is applied across the total resistance r and the electrostatic capacitor is connected across the portion of the total resistance which is marked as r. Now suppose the applied voltage is DC, then we should make one assumption that the capacitor which is connected is having infinite leakage resistance. In this case the multiplying factor is given by the ratio of electrical resistance r/R. The ac operation on this circuit can also be analyzed easily again in case of ac operation we multiplying factor equal to r/R.
(b) By using capacitor multiplier technique: We can increase the range of voltage to be measured by placing a series of capacitors as shown in the given circuit.
capacitor dividerLet us derive the expression for multiplying factor for the circuit diagram 1. Let us mark the capacitance of the voltmeter be C1 and series capacitor be C2 as shown in the given circuit diagram. Now the series combination of these capacitor be equal to
Which is the total capacitance of the circuit. Now the impedance of the voltmeter is equal to Z1 = 1/jωC1 and thus total impedance will be equal to
Now the multiplying factor can be defined as the ratio of Z/Z1 which is equal to 1 + C2 / C1. Similarly the multiplying factor can also be calculated. Hence by this way we can increase the range of voltage to be measure.

Advantages of Electrostatic Type Instruments

Now let us look at some advantages of electrostatic type instruments.

  • The first and the most important advantage is that we can measure both AC and DC voltage and the reason is very obvious the deflecting torque is directly proportional to the square of the voltage.

  • Power consumption is quite low in these types of instruments as the current drawn by these instruments is quite low.

  • We can measure high value of voltage.

Disadvantages of Electrostatic Type Instruments

Instead of various advantages, electrostatic instruments posses few disadvantages and these are written below.

  • These are quite costly as compared to other instruments and also these have large size.

  • The scale is not uniform.

  • The various operating forces involved are small in magnitude.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
PT Fuse Slow Blow: Causes, Detection & Prevention
PT Fuse Slow Blow: Causes, Detection & Prevention
I. Fuse Structure and Root Cause AnalysisSlow Fuse Blowing:From the design principle of fuses, when a large fault current passes through the fuse element, due to the metal effect (certain refractory metals become fusible under specific alloy conditions), the fuse first melts at the soldered tin ball. The arc then rapidly vaporizes the entire fuse element. The resulting arc is quickly extinguished by quartz sand.However, due to harsh operating environments, the fuse element may age under the comb
Edwiin
10/24/2025
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Why Fuses Blow: Overload, Short Circuit & Surge Causes
Common Causes of Fuse BlowingCommon reasons for fuse blowing include voltage fluctuations, short circuits, lightning strikes during storms, and current overloads. These conditions can easily cause the fuse element to melt.A fuse is an electrical device that interrupts the circuit by melting its fusible element due to heat generated when current exceeds a specified value. It operates on the principle that, after an overcurrent persists for a certain period, the heat produced by the current melts
Echo
10/24/2025
Fuse Maintenance & Replacement: Safety and Best Practices
Fuse Maintenance & Replacement: Safety and Best Practices
1. Fuse MaintenanceFuses in service should be regularly inspected. The inspection includes the following items: Load current should be compatible with the rated current of the fuse element. For fuses equipped with a fuse blown indicator, check whether the indicator has actuated. Check the conductors, connection points, and the fuse itself for overheating; ensure connections are tight and making good contact. Inspect the fuse exterior for cracks, contamination, or signs of arcing/discharge. Liste
James
10/24/2025
Maintenance and Repair Items for 10kV High-Voltage Switchgear
Maintenance and Repair Items for 10kV High-Voltage Switchgear
I. Routine Maintenance and Inspection(1) Visual Inspection of Switchgear Enclosure No deformation or physical damage to the enclosure. Protective paint coating shows no severe rust, peeling, or flaking. Cabinet is securely installed, clean on the surface, and free of foreign objects. Nameplates and identification labels are neatly affixed and not falling off.(2) Check of Switchgear Operating Parameters Instruments and meters indicate normal values (comparable to typical operating data, with no s