Hunting in Synchronous Motor

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Hunting in Synchronous Motor

Key learnings:

  • Hunting Defined: Hunting in a synchronous motor is the phenomenon where the rotor oscillates around a new equilibrium position due to sudden changes in load.

  • Causes of Hunting: Hunting can be caused by abrupt load changes, sudden  field current adjustments, harmonic torque loads, or faults in the supply system.

  • Effects of Hunting: This instability may cause the motor to lose synchronism, induce mechanical stresses, increase losses, and elevate temperatures.

  • Reduction Techniques: To reduce hunting, use damper windings to oppose rotor slip and install flywheels to stabilize rotor speed.

  • Types of Synchronous Motor: Understanding different types of  synchronous motors helps in selecting the right motor design to minimize  hunting effects.

We encounter the term “HUNTING” in the context of three phase synchronous motor operations. It describes how the rotor must ‘hunt’ for a new equilibrium position following a sudden load application. This phenomenon is known as hunting in a synchronous motor. Let’s explore the equilibrium condition of a synchronous motor.

A steady state operation of synchronous motor is a condition of equilibrium in which the electromagnetic torque is equal and opposite to load torque. In steady state, rotor runs at synchronous speed thereby maintaining a constant value of torque angle (δ). If there is a sudden change in load torque, the equilibrium is disturbed and there is resulting torque which changes the speed of the motor.

9d766ad59fcfdaa837684cac910a59d2(1).jpeg

What is Hunting?

An unloaded synchronous machine starts with a zero-degree load angle. As the shaft load increases, so does the load angle. If a load, P1, is suddenly applied to an unloaded machine, the machine will momentarily slow down.

Additionally, the load angle (δ) increases from zero to δ1. Initially, the electrical power developed matches the mechanical load, P1. Since equilibrium isn’t reached, the rotor swings past δ1 to δ2, generating more electrical power than before.

The rotor reaches synchronous speed but doesn’t maintain it, accelerating beyond this speed. This acceleration causes the load angle to decrease, preventing the attainment of equilibrium once more.

Consequently, the rotor swings or oscillates around its new equilibrium position, a process known as hunting or phase swinging. Hunting occurs in both synchronous motors and generators when there’s an abrupt load change.

Causes of Hunting in Synchronous Motor 

  • Sudden change in load.

  • Sudden change in field current.

  •  A load containing harmonic torque.

  •  Fault in supply system.

Effects of Hunting in Synchronous Motor

  • It may lead to loss of synchronism.

  • Produces mechanical stresses in the rotor shaft.

  • Increases machine losses and cause temperature rise.

  • It increases possibility of resonance.

Reduction of Hunting in Synchronous Motor

Two techniques should be used to reduce hunting. These are –

•    Use of Damper Winding: It consists of low electrical resistance copper / aluminum brush embedded in slots of pole faces in salient pole machine. Damper winding damps out hunting by producing torque opposite to slip of rotor. The magnitude of damping torque is proportional to the slip speed.

•    Use of Flywheels: The prime mover is provided with a large and heavy flywheel. This increases the inertia of prime mover and helps in maintaining the rotor speed constant.

•    Designing synchronous machine with suitable synchronizing power coefficients.

Give a tip and encourage the author!
Recommended
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
SST Technology: Full-Scenario Analysis in Power Generation, Transmission, Distribution, and Consumption
I. Research BackgroundPower System Transformation NeedsChanges in energy structure are placing higher demands on power systems. Traditional power systems are transitioning toward new-generation power systems, with the core differences between them outlined as follows: Dimension Traditional Power System New-Type Power System Technical Foundation Form Mechanical Electromagnetic System Dominated by Synchronous Machines and Power Electronic Equipment Generation-Side Form M
Echo
10/28/2025
Rectifier vs Power Transformer: Key Differences
Rectifier vs Power Transformer: Key Differences
Differences Between Rectifier Transformers and Power TransformersRectifier transformers and power transformers both belong to the transformer family, but they differ fundamentally in application and functional characteristics. The transformers commonly seen on utility poles are typically power transformers, while those supplying electrolytic cells or electroplating equipment in factories are usually rectifier transformers. Understanding their differences requires examining three aspects: working
Echo
10/27/2025
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST Transformer Core Loss Calculation and Winding Optimization Guide
SST High-Frequency Isolated Transformer Core Design and Calculation Material Characteristics Impact:Core material exhibits varying loss behavior under different temperatures, frequencies, and flux densities. These characteristics form the foundation of overall core loss and require precise understanding of nonlinear properties. Stray Magnetic Field Interference:High-frequency stray magnetic fields around windings can induce additional core losses. If not properly managed, these parasitic losses
Dyson
10/27/2025
Upgrade Traditional Transformers: Amorphous or Solid-State?
Upgrade Traditional Transformers: Amorphous or Solid-State?
I. Core Innovation: A Dual Revolution in Materials and StructureTwo key innovations:Material Innovation: Amorphous AlloyWhat it is: A metallic material formed by ultra-rapid solidification, featuring a disordered, non-crystalline atomic structure.Key Advantage: Extremely low core loss (no-load loss), which is 60%–80% lower than that of traditional silicon steel transformers.Why it matters: No-load loss occurs continuously, 24/7, throughout a transformer’s lifecycle. For transformers with low loa
Echo
10/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.