What is Maximum Demand Indicator?

Edwiin
Edwiin
Field: Power switch
China

Definition: The maximum demand indicator is used to measure the maximum amount of power consumed by a consumer within a specific time interval. It is designed to measure base and peak loads, but it cannot measure sudden short - circuit currents or the high starting currents of motors. Its purpose is to record power consumption over specific periods.

The maximum demand indicators are categorized into four types:

  • Recording demand indicator

  • Average demand indicator

  • Thermal type maximum demand indicator

  • Digital Maximum Demand Indicator

Construction of Maximum Demand Indicator

The maximum demand indicator comprises five main components:

  • A dial connected to the moving system

  • A pointer

  • A reset device

  • A fraction device

  • An indicating pin

Average Demand Indicator

The average demand indicator is integrated into the energy meter. Together, the energy meter and the average demand indicator measure the total power consumption and the maximum value of specific power within a particular time interval. The average demand indicator features a sophisticated speed - dial mechanism.

The pin drive advances the dial for a short period (e.g., half an hour). The total power consumed during that interval is displayed on the dial. The instrument has a cam that is regulated by timing gears. The cam resets the pointer to the zero position.

The pointer records the total power consumed by the load within that specific time interval. In the next half - hour, the pin moves forward again. However, the pointer will only move forward if the total power consumed by the load exceeds that of the previous period.

A formula is used to calculate the average maximum demand.

The maximum demand meter is capable of measuring power in terms of kilovolt - ampere - hours reactive (kVarh) or kilovolt - ampere - hours (kVah). This functionality is achieved by incorporating an appropriate meter that can compute these quantities accurately.

Advantages of Average Demand Indicator

  • The average demand indicator offers a high degree of accuracy in measurement.

  • It features a consistent and uniform measuring scale, ensuring reliable and comparable readings.

Disadvantages of Maximum Demand Indicator

  • One of the primary drawbacks is the relatively high cost of the instrument, which can pose a significant investment barrier.

  • Its construction is intricate and complex, requiring specialized knowledge and skills for installation, maintenance, and repair.

In modern applications, technological advancements have led to significant changes in its design. Specifically, the traditional cam mechanism has been replaced by an electromagnetic relay, and the bell crank releasing device is now commonly substituted with a clutch, enhancing operational efficiency and reliability.

Give a tip and encourage the author!
Recommended
Three-Phase SPD: Types, Wiring & Maintenance Guide
Three-Phase SPD: Types, Wiring & Maintenance Guide
1. What Is a Three-Phase Power Surge Protective Device (SPD)?A three-phase power surge protective device (SPD), also known as a three-phase lightning arrester, is specifically designed for three-phase AC power systems. Its primary function is to limit transient overvoltages caused by lightning strikes or switching operations in the power grid, thereby protecting downstream electrical equipment from damage. The SPD operates based on energy absorption and dissipation: when an overvoltage event occ
James
12/02/2025
Railway 10kV Power Through Lines: Design & Operation Requirements
Railway 10kV Power Through Lines: Design & Operation Requirements
The Daquan Line has a large power load, with numerous and scattered load points along the section. Each load point has a small capacity, with an average of one load point every 2-3 km, so two 10 kV power through lines should be adopted for power supply. High-speed railways use two lines for power supply: primary through line and comprehensive through line. The power sources of the two through lines are taken from the dedicated bus sections fed by the voltage regulators installed in each power di
Edwiin
11/26/2025
Analysis of Causes of Power Line Loss and Loss Reduction Methods
Analysis of Causes of Power Line Loss and Loss Reduction Methods
In power grid construction, we should focus on actual conditions and establish a grid layout suitable for our own needs. We need to minimize power loss in the grid, save social resource investment, and comprehensively improve China's economic benefits. Relevant power supply and electricity departments should also set work goals centered on effectively reducing power loss, respond to energy conservation calls, and build green social and economic benefits for China.1.Current Status of China's Powe
Echo
11/26/2025
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Railway power systems primarily consist of automatic block signaling lines, through-feeder power lines, railway substations and distribution stations, and incoming power supply lines. They provide electricity to critical railway operations—including signaling, communications, rolling stock systems, station passenger handling, and maintenance facilities. As an integral part of the national power grid, railway power systems exhibit distinct characteristics of both electrical power engineering and
Echo
11/26/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.