Split Phase Induction Motor

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

The Split Phase Motor, alternatively referred to as a Resistance Start Motor, features a single - cage rotor. Its stator is equipped with two distinct windings: the main winding and the starting winding. These two windings are spatially displaced by 90 degrees, a configuration that plays a crucial role in the motor's operation.

The main winding is characterized by its very low resistance and high inductive reactance, while the starting winding exhibits the opposite characteristics, with high resistance and low inductive reactance. This disparity in electrical properties between the two windings is key to generating the necessary torque for starting the motor. The connection diagram of this motor is presented below, illustrating how these components interact within the electrical circuit:

image.png

A resistor is connected in series with the auxiliary (starting) winding. Due to this arrangement, the currents flowing through the two windings differ. Consequently, the resulting rotating magnetic field is non - uniform, leading to a relatively small starting torque. Typically, this starting torque is in the range of 1.5 to 2 times the specified running torque. At the moment of starting, both the main and starting windings are connected in parallel across the power supply.

Once the motor accelerates to approximately 70 - 80% of the synchronous speed, the starting winding is automatically disconnected from the power source. For motors with a rating of around 100 Watts or higher, a centrifugal switch is commonly employed to perform this disconnection. In contrast, for lower - rated motors, a relay serves the purpose of disconnecting the starting winding.

A relay is connected in series with the main winding. During the starting phase, a significant amount of current surges through the circuit, which causes the relay contacts to close. This action places the starting winding into the circuit. As the motor approaches its predetermined operating speed, the current flowing through the relay begins to decline. Eventually, the relay opens, severing the connection of the auxiliary winding from the power supply. At this point, the motor continues to operate solely on the main winding.

The phasor diagram of the Split Phase Induction Motor, which elucidates the electrical relationships and phase differences within the motor, is depicted below:

image.png

The current in the main winding, denoted as IM, lags behind the supply voltage V by nearly 90 degrees. In contrast, the current in the auxiliary winding, IA, is approximately in phase with the line voltage. This disparity in the phase relationship between the two windings results in a time difference between their currents. While the time phase difference ϕ is not a full 90 degrees, typically around 30 degrees, it is sufficient to generate a rotating magnetic field. This rotating magnetic field is crucial for initiating the motor's rotation and enabling it to operate.

The Torque - Speed Characteristic of the Split Phase motor, which illustrates how the torque output of the motor varies with its rotational speed, is presented below. This characteristic curve provides valuable insights into the motor's performance under different operating conditions and is essential for understanding its behavior and optimizing its use in various applications.

image.png

In the torque - speed characteristic of the Split Phase motor, n0 marks the rotational speed at which the centrifugal switch activates. The starting torque of the resistance - start motor typically measures around 1.5 times its full - load torque. At approximately 75% of the synchronous speed, the motor can achieve a maximum torque that is roughly 2.5 times the full - load torque. However, it's important to note that during starting, the motor draws a substantial current, amounting to about 7 to 8 times the full - load value.

Reversing the direction of a Resistance Start motor is a straightforward process. It can be accomplished by simply reversing the line connection of either the main winding or the starting winding. It's crucial to emphasize that this reversal can only be carried out when the motor is at a standstill; attempting to reverse it while in motion can lead to mechanical and electrical damage.

Applications of Split Phase Induction Motor

Split Phase Induction Motors are renowned for their affordability. They are well - suited for applications involving loads that are easy to start, especially when the frequency of starting operations is relatively low. Due to their limited starting torque, these motors are not ideal for drives requiring more than 1 KW of power. Nevertheless, they find extensive use in a wide range of common household and industrial appliances:

  • Home Appliances: They power components such as washing machines and air - conditioning fans, facilitating the smooth operation of these essential devices.

  • Kitchen and Cleaning Equipment: In the kitchen, they drive mixer grinders, while in cleaning applications, they are used in floor polishers, making daily chores more convenient.

  • Fluid Handling and Ventilation: Blowers and centrifugal pumps, which are vital for ventilation and fluid transportation in various systems, often rely on Split Phase Induction Motors for their operation.

  • Machining Tools: These motors also play a role in drilling and lathe machines, contributing to the precision and efficiency of machining processes.

In summary, the Split Phase Induction Motor, with its distinct characteristics and practical applications, remains a valuable component in the world of electrical engineering.

Give a tip and encourage the author!
Recommended
How to Choose a Thermal Relay for Motor Protection?
How to Choose a Thermal Relay for Motor Protection?
Thermal Relays for Motor Overload Protection: Principles, Selection, and ApplicationIn motor control systems, fuses are primarily used for short-circuit protection. However, they cannot protect against overheating caused by prolonged overloading, frequent forward-reverse operation, or undervoltage operation. Currently, thermal relays are widely used for motor overload protection. A thermal relay is a protective device that operates based on the thermal effect of electric current, and is essentia
James
10/22/2025
How to Choose & Maintain Electric Motors: 6 Key Steps
How to Choose & Maintain Electric Motors: 6 Key Steps
"Selecting a High-Quality Motor" – Remember the Six Key Steps Inspect (Look): Check the motor’s appearanceThe motor’s surface should have a smooth, even paint finish. The nameplate must be properly installed with complete and clear markings, including: model number, serial number, rated power, rated current, rated voltage, allowable temperature rise, connection method, speed, noise level, frequency, protection rating, weight, standard code, duty type, insulation class, manufacturing date, and ma
Felix Spark
10/21/2025
 What Is the Working Principle of a Power Plant Boiler?
What Is the Working Principle of a Power Plant Boiler?
The working principle of a power plant boiler is to utilize the thermal energy released from fuel combustion to heat feedwater, producing a sufficient quantity of superheated steam that meets specified parameters and quality requirements. The amount of steam produced is known as the boiler's evaporation capacity, typically measured in tons per hour (t/h). Steam parameters primarily refer to pressure and temperature, expressed in megapascals (MPa) and degrees Celsius (°C), respectively. Steam qua
Edwiin
10/10/2025
What is the principle of live-line washing for substations?
What is the principle of live-line washing for substations?
Why Do Electrical Equipment Need a "Bath"?Due to atmospheric pollution, contaminants accumulate on insulating porcelain insulators and posts. During rain, this can lead to pollution flashover, which in severe cases may cause insulation breakdown, resulting in short circuits or grounding faults. Therefore, the insulating parts of substation equipment must be periodically washed with water to prevent flashover and avoid insulation degradation that could lead to equipment failure.Which Equipment Is
Encyclopedia
10/10/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.