Motor protection

Encyclopedia
09/10/2024

Motor protection set


Motor protection is a set of devices and methods to protect a motor from failure and damage.


Type of motor fault


  • External motor fault

  • Unbalanced supply voltage

  • undervoltage

  • Reverse phase sequence

  • Loss of synchronization


Internal motor fault


  • Bearing failure

  • superheating

  • Winding fault

  • Ground fault


Motor protection device


  • Fuses: Fuses protect the motor by melting and interrupting the circuit during overload or short circuit.



  • Circuit breaker: The circuit breaker can be reset after an interruption failure and provides overload and undervoltage protection.



  • Overload relays: These devices interrupt circuits when large currents flow through them due to overload.



  • Thermal overload relays:  These devices use bimetal sheets or heating elements to sense the temperature rise of the motor current. When the current exceeds a preset value, the thermal element will bend or melt, causing the contact to open or close.



  •  Electronic or digital overload relays: These devices use a current transformer or shunt resistor to measure the motor current and use a microprocessor or solid-state circuit to control the contacts.



  •   Differential protective relays: These are devices that compare the current of a motor or its winding input and output terminals. When the current difference exceeds a certain value, it indicates that there is a winding fault, and the relay will trip the circuit.



  • Reverse protection relay: A device that detects the direction of rotation of a motor and prevents it from running in reverse.



Select motor protection equipment


Type and size of motor


  • Characteristics and ratings of the motor

  • Type and severity of the possible fault

  • NEC and other standard requirements

  • Cost and availability of equipment


Conclusion


Motor protection is an important aspect of electrical engineering, ensuring the safety and efficiency of motors and their circuits. Motor protection equipment is selected based on the type and size of the motor, the type and severity of possible failures, the requirements of NEC and other standards, and the cost and availability of the equipment. Motor protection devices include fuses, circuit breakers, overload relays, differential protection relays and reverse protection relays. Motor protection devices monitor and control parameters such as current, voltage, temperature, speed and torque to prevent or minimize damage to the motor and its circuits in the event of a failure or anomaly.


Encyclopedia

The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
Analysis of the Technical Characteristics of Online Monitoring for Medium-Voltage Switchgear Status
With the increasing complexity of power system operation environment and the deepening of power system reform, traditional power grids are accelerating the transformation to smart grids. The goal of equipment condition-based maintenance is achieved through real-time perception of equipment status by new sensors, reliable communication via modern network technology, and effective monitoring by background expert systems.I. Analysis of Condition-based Maintenance StrategyCondition-based Maintenance
Oliver Watts
06/11/2025
What is the current application status and development trend of medium-voltage switchgear?
What is the current application status and development trend of medium-voltage switchgear?
With the accelerated automation of power equipment, various medium-voltage switchgear have emerged in the market. Classified by insulation media, they are mainly divided into air-insulated, SF₆ gas-insulated and solid-insulated types, each with its own advantages and disadvantages: solid insulation offers good performance but poor environmental friendliness, SF₆ features excellent arc extinguishing capability but is a greenhouse gas, and air insulation has high cost-performance but larger volume
Echo
06/11/2025
What components make up the design of medium-voltage ring network distribution switchgear?
What components make up the design of medium-voltage ring network distribution switchgear?
As an expert who has been deeply engaged in the field of power system design for many years, I have always paid attention to the technological evolution and application practice of medium-voltage ring main distribution equipment. As a core electrical device in the secondary distribution link of the power system, the design and performance of such equipment are directly related to the safe and stable operation of the power supply network. The following is a professional analysis of the key design
Dyson
06/11/2025
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
What aspects should be paid attention to when installing medium-voltage switch cabinets during the initial stage of subway operation?
1. Statistics on Common Faults of Medium-Voltage Switchgear in the Early Operation StageAs project participants, we found during the early operation of a new metro line: 21 sets of power supply equipment were put into use, with a total of 266 accident phenomena in the first year. Among them, 77 faults occurred in medium-voltage switchgear, accounting for 28.9%—significantly higher than faults in other equipment. Statistical analysis shows that major fault types include: protection device s