Implementation of Precast Foundations for Ring-Main Unit Compact Substations in Grid Modernization Initiatives

Echo
Echo
Field: Transformer Analysis
China

Compact substation boxes, with advantages like safe operation, high reliability, and easy maintenance, are used in urban grid construction/renovation. Structurally divided into American - style (high - cost, noisy, low - efficiency, gradually phased out) and European - style (large - sized but more advantages, still popular).

To address their pros/cons, ring - network prefabricated ones were developed.

I. Basic Materials for Prefabricated Compact Substation Boxes

Materials need hardness, strength, corrosion resistance, and factory - configurability. Analysis of common options:

  • Steel:Short construction cycle; components processable off - site. Low splicing/technical requirements, no special maintenance.

  • Plastic:High forming - tech/strength demands → rarely used.

  • Plastic - steel:Solves load - bearing via steel strength but costly → limited by cost.

II. Design of Prefabricated Compact Substation

The design concept, rooted in real - grid operation, pursues typicality and universality. To ease transport, minimize the substation foundation’s self - weight, streamlining design, manufacturing, construction, and transport. Shorten the construction period and cut effective costs as much as possible.

III. Analysis of Manufacturing Processes

Mature processes exist for prefabricated compact substation foundations:

(I) Steel - structured Ring - network Substation Process

Per regulations, the process follows: template making → cutting → splicing → welding → curing → surface protection. Strengthen tech and quality control at each step to ensure quality.

(II) Glass Fiber Cloth Pasting Process

The process: surface treatment → line - setting & gluing → pasting fiber cloth → curing & surface protection.

  • Surface Treatment: Remove dust, grind smooth to expose steel’s properties, ensuring construction quality.

  • Pasting & Positioning: Strictly follow design drawings; paste on the glass fiber board’s positioning line.

  • Fiber Glass Pasting: Grind surfaces, cut/measure per size, ensure material integrity and accurate positioning; avoid surface contamination.

  • Surface Protection: Post - process, fix the board as designed, and do final correction/protection.

IV. conclusion

The ring - network prefabricated substation foundation suits universal scenarios, boasting good load - bearing, light weight, and corrosion resistance. It simplifies construction, boosts efficiency, cuts costs, and leverages other materials to overcome drawbacks. It holds broad prospects for future R & D and applications.

Steel is chosen (suits prefab, shortens schedule). To fix steel’s poor corrosion resistance, paste glass fiber cloth on its surface during construction to boost durability.

Give a tip and encourage the author!
Recommended
3D Wound-Core Transformer: Future of Power Distribution
3D Wound-Core Transformer: Future of Power Distribution
Technical Requirements and Development Trends for Distribution Transformers Low losses, especially low no-load losses; highlighting energy-saving performance. Low noise, particularly during no-load operation, to meet environmental protection standards. Fully sealed designto prevent transformer oil from contacting external air, enabling maintenance-free operation. Integrated protection devices within the tank, achieving miniaturization; reducing transformer size for easier on-site installation. C
Echo
10/20/2025
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digital MV Circuit Breakers
Reduce Downtime with Digitized Medium-Voltage Switchgear and Circuit Breakers"Downtime" — it’s a word no facility manager wants to hear, especially when it’s unplanned. Now, thanks to next-generation medium-voltage (MV) circuit breakers and switchgear, you can leverage digital solutions to maximize uptime and system reliability.Modern MV switchgear and circuit breakers are equipped with embedded digital sensors that enable product-level equipment monitoring, providing real-time insights into the
Echo
10/18/2025
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
One Article to Understand the Contact Separation Stages of a Vacuum Circuit Breaker
Vacuum Circuit Breaker Contact Separation Stages: Arc Initiation, Arc Extinction, and OscillationStage 1: Initial Opening (Arc Initiation Phase, 0–3 mm)Modern theory confirms that the initial contact separation phase (0–3 mm) is critical to the interrupting performance of vacuum circuit breakers. At the beginning of contact separation, the arc current always transitions from a constricted mode to a diffused mode—the faster this transition, the better the interruption performance.Three measures c
Echo
10/16/2025
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Advantages & Applications of Low-Voltage Vacuum Circuit Breakers
Low-Voltage Vacuum Circuit Breakers: Advantages, Application, and Technical ChallengesDue to their lower voltage rating, low-voltage vacuum circuit breakers have a smaller contact gap compared to medium-voltage types. Under such small gaps, transverse magnetic field (TMF) technology is superior to axial magnetic field (AMF) for interrupting high short-circuit currents. When interrupting large currents, the vacuum arc tends to concentrate into a constricted arc mode, where localized erosion zones
Echo
10/16/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.