What is Synchro?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

What is Synchro?

Definition

A Synchro is a type of transducer that converts the angular position of a shaft into an electrical signal. It functions as both an error detector and a rotary position sensor. Errors in the system often occur due to shaft misalignment. The two main components of a synchro are the transmitter and the control transformer.

Synchro System Types

There are two types of synchro systems:

Control Type Synchro

  • Torque Transmission Type Synchro

  • Torque Transmission Type Synchros

This kind of synchro has a relatively small output torque. As a result, it is suitable for driving very light loads such as a pointer. In contrast, the control type synchro is designed for driving larger loads.

Control Type Synchros System

Control synchros are utilized for error detection in positional control systems. Their systems are composed of two units:

  • Synchro Transmitter

  • Synchro Receiver

A synchro always operates in tandem with these two parts. The following provides a detailed explanation of the synchro transmitter and receiver.

Synchros Transmitter

Its construction bears resemblance to that of a three - phase alternator. The stator of the synchro is made of steel to minimize iron losses. The stator is slotted to accommodate the three - phase windings. The axes of the stator windings are set 120º apart from one another.

0000.jpg

where (Vr) is the root - mean - square (r.m.s.) value of the rotor voltage, and ωc) is the carrier frequency.The coils of the stator windings are connected in a star configuration. The rotor of the synchro has a dumbbell - like shape, with a concentric coil wound around it. An alternating current (AC) voltage is applied to the rotor through slip rings. The constructional features of the synchro are depicted in the figure below.Consider the voltage is applied to the rotor of the transmitter as shown in the figure above. 

11.jpg

When a voltage is applied to the rotor, it induces a magnetizing current, which in turn generates an alternating flux along the rotor's axis. Due to the mutual induction between the rotor and stator fluxes, a voltage is induced in the stator windings. The flux linkage in the stator winding is proportional to the cosine of the angle between the axes of the rotor and the stator. As a result, a voltage is induced in the stator winding.Let V1, V2, and V3 be the voltages induced in the stator windings S1, S2, and S3 respectively. The figure below illustrates the rotor position of the synchro transmitter. Here, the rotor axis forms an angle θr with respect to the stator winding S2.

image.png

The three terminals of the stator windings are

image.png

The variation in the stator terminal axis concerning the rotor is shown in the figure below.

image.png

When the rotor angle is zero, the maximum current is induced in the stator winding S2. The zero - position of the rotor serves as a reference for determining the angular position of the rotor.

The output of the transmitter is fed to the stator winding of the control transformer, as depicted in the figure above.

Currents of the same magnitude flow through the transmitter and the control transformer of the synchro system. Due to this circulating current, a flux is established within the air - gap of the control transformer.

The flux axes of the control transformer and the transmitter are in the same alignment. The voltage induced in the rotor of the control transformer is proportional to the cosine of the angle between the rotors of the transmitter and the control transformer. Mathematically, the voltage is expressed as

image.png

Where φ represents the angular displacement between the rotor axes of the transmitter and the controller. When θ-90, the axes of the rotors of the transmitter and the control transformer are perpendicular to each other. The figure above depicts the zero - position of the rotors of the transmitter and the receiver.

Suppose the rotors of the transmitter and the control transformer rotate in the same direction. Let the rotor of the transmitter be deflected by an angle θR, and the deflection angle of the control transformer's rotor be θC . Then, the total angular separation between the two rotors is (90º – θR + θC)

The voltage at the rotor terminals of the synchro transformer is given as

image.png

The small angular displacement between their rotor position is given as Sin (θR – θC) = (θR – θC)

On substituting the value of angular displacement in equation (1) we get

image.png

The synchro transmitter and the control transformer together used for detecting the error. The voltage equation shown above is equal to the shaft position of the rotors of control transformer and transmitter.

21.jpg

The error signal is applied to the differential amplifier which gives input to the servo motor. The gear of the servo motor rotates the rotor of the control transformer 

23.jpg

The figure above shows the output of the synchro error detector which is a modulated signal. The modulating wave above shown the misalignment between the rotor position and the carrier wave. 

image.png


Give a tip and encourage the author!
Recommended
MVDC: Future of Efficient, Sustainable Power Grids
MVDC: Future of Efficient, Sustainable Power Grids
The Global Energy Landscape Is Undergoing a Fundamental Transformation toward a "fully electrified society," characterized by widespread carbon-neutral energy and the electrification of industry, transportation, and residential loads.In today’s context of high copper prices, critical mineral conflicts, and congested AC power grids, Medium-Voltage Direct Current (MVDC) systems can overcome many limitations of traditional AC networks. MVDC significantly enhances transmission capacity and efficienc
Edwiin
10/21/2025
Grounding Causes of Cable Lines and the Principles of Incident Handling
Grounding Causes of Cable Lines and the Principles of Incident Handling
Our 220 kV substation is located far from the urban center in a remote area, surrounded primarily by industrial zones such as Lanshan, Hebin, and Tasha Industrial Parks. Major high-load consumers in these zones—including silicon carbide, ferroalloy, and calcium carbide plants—account for approximately 83.87% of our bureau’s total load. The substation operates at voltage levels of 220 kV, 110 kV, and 35 kV.The 35 kV low-voltage side mainly supplies feeders to ferroalloy and silicon carbide plants
Felix Spark
10/21/2025
Overhead Power Lines & Towers: Types, Design & Safety
Overhead Power Lines & Towers: Types, Design & Safety
Besides ultra-high voltage AC substations, what we encounter more frequently are power transmission and distribution lines. Tall towers carry conductors that leap across mountains and seas, stretching into the distance before reaching cities and villages. This is also an interesting topic—today, let's explore transmission lines and their supporting towers.Power Transmission and DistributionFirst, let’s understand how electricity is delivered. The electric power industry primarily consists of fou
Encyclopedia
10/21/2025
Automatic Reclosing Modes: Single, Three-Phase & Composite
Automatic Reclosing Modes: Single, Three-Phase & Composite
General Overview of Automatic Reclosing ModesTypically, automatic reclosing devices are categorized into four modes: single-phase reclosing, three-phase reclosing, composite reclosing, and disabled reclosing. The appropriate mode can be selected based on load requirements and system conditions.1. Single-Phase ReclosingMost 110kV and higher transmission lines employ three-phase single-shot reclosing. According to operational experience, over 70% of short-circuit faults in high-voltage overhead li
Edwiin
10/21/2025
Send inquiry
Download
Get the IEE Business Application