Research on Reliability Enhancement Scheme Implementation for Modular Intelligent Prefabricated Substations

Echo
Echo
Field: Transformer Analysis
China

1 Implementation Strategies for the Scheme
1.1 Deepen Survey and Research

Before constructing prefabricated cabin - type substations, it is necessary to conduct detailed surveys of local working conditions, clarify the construction scale and objectives, evaluate existing power facilities, plan projects, make up for infrastructure shortcomings, and adjust the construction rhythm. Meanwhile, control costs to avoid project suspension.

1.2 Strengthen Structural Construction

During promotion, multi - dimensional optimization is needed. Design and construction should balance safety and practicality, and incorporate innovative thinking. The cabinets of pre - installed substations adopt an integrated welded structure. The underframe, framework, etc., undergo anti - corrosion treatment for long - term durability; the double - layer structure + heat insulation design controls temperature, and the polyurethane insulation and six - degree anti - corrosion process help improve performance. The anti - corrosion diagram is shown in Figure 1.

The cabinet adopts a high - quality cold - rolled steel steel shell, with sufficient mechanical strength. The minimum top load is 2500N/m²; it can withstand an external mechanical impact energy of 20J, and the corresponding protection level conforms to IK10 specified in GB/T 20138. Meanwhile, it meets the seismic requirements of a horizontal acceleration of 0.3 (g) and a vertical acceleration of 0.15 (g), and has obtained the seismic report issued by the Institute of Engineering Mechanics, China Earthquake Administration.

1.3 Optimization of Internal Control Environment

Modular intelligent prefabricated cabin substations, despite their high flexibility, require critical optimization of the internal control environment. The interior should adopt a concise control model: enhancing response speed of control functions, predicting and eliminating risks, while also adapting to operators' habits for faster system feedback.

For instance, the structure uses "double - layer metal plates + single - layer metal decorative panels", incorporates refrigerator - style insulation technology with polyurethane foam filling, and applies thermal - break insulation to doors/windows (as shown in Figure 2), optimizing the environment at the physical level.

Considering climate and environment, in harsh areas (heavy wind - sand, extreme cold, high pollution), prefabricated cabins use micro - positive pressure dust - prevention tech. Cabin pressure stays at 1.05×external pressure for dust, moisture, and condensation prevention, ensuring equipment stability.

The micro - positive pressure AC integrates micro - positive pressure and air - conditioning systems. It supplies clean air to sealed cabins, keeping internal pressure slightly higher than external; air leaking from door/window gaps flows outward, blocking dust and creating a dust - free environment. The AC also regulates temperature and humidity for constancy. In winter’s low temperatures, as an industrial AC, it starts at - 30 °C, with electric auxiliary heating and the cabin’s good thermal insulation, maintaining a suitable internal operating environment.

1.4 Improving Design Details

Modular intelligent prefabricated cabin substations optimize functions via detail design, use materials complying with regulations, and deliver remarkable benefits.

(1) Lighting System
Explosion - proof LED corridor lights are installed in the inspection corridor, with self - starting emergency lights at both ends for power - off scenarios. Inspection lights are set in unit cabinets, with switches on the operation panel.

(2) Busbars & Cables
For busbars penetrating the cabin top, non - magnetic materials (stainless steel/aluminum) are used for clamps, door panels/frames to avoid eddy currents. Primary and secondary cables are laid independently in sealed channels: The primary channel uses double - layered galvanized sheets + aluminum silicate insulation (Class A fire resistance), matching cable layout. The secondary uses metal trunking, considering anti - interference and shielding.

(3) Settlement Response
Settlement easily damages high - current hard busbars. Thus, fully insulated segmented solid busbars are adopted. Wiring reserves soft - connection nodes and stress - relief bends to compensate for tension and maintain insulation.

1.5 Innovating Maintenance Mechanisms

The operation and maintenance mode should match modular features and cabin functions, ensuring safety, stability, and quick fault removal for upgrades.

1.5.1 Guardrails and Cabin Access Ladders

For multi - level substation construction, protective guardrails are installed around the second - floor cabin. Specifications of the cabin access ladder: The steps are flush with the base of the guardrails; the steps are grid - type (slope > 55&deg;, width < 250mm, height difference between steps > 300mm ), and handrails are equipped on both sides (see Figure 3).

1.5.2 Reserved Test Openings for Cabinet Equipment

Cabinet - type equipment reserves test openings for test tooling installation and voltage - withstand tests. Daily inspection/maintenance uses the internal corridor (width &ge; 1200mm); during repairs, open the opposite inspection door. An emergency escape platform is installed &ndash; personnel evacuate to it and slide down in emergencies.

With reserved intervals, cabinet design leaves space for GIS expansion (considering reliability/ease). The top cover splits into 4 modules. For expansion, remove relevant covers, hoist expanded GIS into the cabinet, and assemble.

2 Development Trends

Modular intelligent prefabricated cabin substations need innovative development: The control system integrates intelligent, automation, and big - data technologies to break through the limitations of traditional control, accurately locate and resolve faults; strengthen safety protection, identify external impacts (e.g., lightning protection), and improve drills for extreme disasters.

3 Conclusion

Modular intelligent prefabricated cabin substations can solve problems of traditional construction and support long - term optimization. In the future, the technical system needs to be improved, integrating construction technologies, equipment, and management; during promotion, connect with existing power projects and systems to achieve sustainable development.

Give a tip and encourage the author!
Recommended
Minimum Operating Voltage for Vacuum Circuit Breakers
Minimum Operating Voltage for Vacuum Circuit Breakers
Minimum Operating Voltage for Trip and Close Operations in Vacuum Circuit Breakers1. IntroductionWhen you hear the term "vacuum circuit breaker," it might sound unfamiliar. But if we say "circuit breaker" or "power switch," most people will know what it means. In fact, vacuum circuit breakers are key components in modern power systems, responsible for protecting circuits from damage. Today, let's explore an important concept — the minimum operating voltage for trip and close operations.Though it
Dyson
10/18/2025
Efficient Wind-PV Hybrid System Optimization with Storage
Efficient Wind-PV Hybrid System Optimization with Storage
1. Analysis of Wind and Solar Photovoltaic Power Generation CharacteristicsAnalyzing the characteristics of wind and solar photovoltaic (PV) power generation is fundamental to designing a complementary hybrid system. Statistical analysis of annual wind speed and solar irradiance data for a specific region reveals that wind resources exhibit seasonal variation, with higher wind speeds in winter and spring and lower speeds in summer and autumn. Wind power generation is proportional to the cube of
Dyson
10/15/2025
Wind-Solar Hybrid Powered IoT System for Real-Time Water Pipeline Monitoring
Wind-Solar Hybrid Powered IoT System for Real-Time Water Pipeline Monitoring
I. Current Status and Existing ProblemsCurrently, water supply companies have extensive networks of water pipelines laid underground across urban and rural areas. Real-time monitoring of pipeline operation data is essential for effective command and control of water production and distribution. As a result, numerous data monitoring stations must be established along the pipelines. However, stable and reliable power sources near these pipelines are rarely available. Even when power is accessible,
Dyson
10/14/2025
How to Build an AGV-Based Intelligent Warehouse System
How to Build an AGV-Based Intelligent Warehouse System
Intelligent Warehouse Logistics System Based on AGVWith the rapid development of the logistics industry, growing land scarcity, and rising labor costs, warehouses—serving as key logistics hubs—are facing significant challenges. As warehouses become larger, operational frequencies increase, information complexity grows, and order-picking tasks become more demanding, achieving low error rates and reduced labor costs while improving overall storage efficiency has become a primary goal for the wareh
Dyson
10/08/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.