How to Determine the Current through an Inductor at Extremely Low Frequencies

When operating at extremely low frequencies (such as DC or near-DC frequencies), the current flowing through an inductor can be determined by analyzing the behavior of the circuit. Since an inductor exhibits very low impedance at DC or extremely low frequencies, it can almost be considered a short circuit. However, for more precise determination of the current at these frequencies, several factors need to be considered:

1. DC Resistance (DCR) of the Inductor

An inductor is not an ideal component; it has a certain amount of wire resistance known as the DC resistance (DCR). At extremely low frequencies or DC conditions, the inductive reactance (XL=2πfL) is negligible, so the current is primarily limited by the inductor's DC resistance.

If the circuit consists only of an inductor and a power source, with the inductor's DC resistance being RDC , the current I can be calculated using Ohm's Law:

7748c24b67b953b185715306075de7d6.jpeg

where V is the supply voltage.

2. Effect of the Time Constant

At extremely low frequencies, the current through the inductor does not immediately reach its steady-state value but gradually increases to that value. This process is governed by the circuit's time constant τ, which is defined as:

494d75852cbd8c340cf804b8a105ea24.jpeg

where L is the inductance and R DC is the inductor's DC resistance.The current as a function of time can be described by the following equation

166f0c654426e3439ad7f9d2aee2a198.jpeg

where Ifinal =V/RDC is the steady-state current, and t is time.

This means that the current starts at zero and gradually increases, reaching approximately 99% of its steady-state value after about 5τ.

3. Type of Power Source

DC Power Source: If the power source is a constant DC voltage, the current will eventually stabilize at I=V/R DC after sufficient time.

Extremely Low Frequency AC Power Source: If the power source is a sinusoidal or pulsed waveform at an extremely low frequency, the current will vary with the instantaneous voltage of the source. For an extremely low-frequency sine wave, the peak current can be approximated as:

b55cd976302d70ae9d95159eeefc477f.jpeg

where V peak is the peak voltage of the source.

4. Other Components in the Circuit

If the circuit contains other components besides the inductor (such as resistors or capacitors), their effects on the current must be considered. For example, in an RL circuit, the rate at which the current grows is influenced by both the resistance R and the inductance L, with the time constant τ=L/R.

If the circuit includes a capacitor, the charging and discharging of the capacitor will also affect the current, especially during transient periods.

5. Non-Ideal Effects of the Inductor

Real inductors may have parasitic capacitance and core losses. At extremely low frequencies, the effect of parasitic capacitance is usually negligible, but core losses can cause the inductor to heat up, affecting its performance. If the inductor uses magnetic material (such as an iron core), magnetic saturation can also be an issue, especially under high current conditions. When an inductor saturates, its inductance L drops significantly, leading to a rapid increase in current.

6. Measurement Methods

Steady-State Current Measurement: To measure the steady-state current, a current meter can be used to directly measure the current flowing through the inductor once the circuit has reached a stable state.

Transient Current Measurement: To measure the current as it changes over time, an oscilloscope or another instrument capable of capturing transient responses can be used. By observing the current waveform, you can analyze how the current grows and reaches its final value.

7. Special Case: Magnetic Saturation

If the inductor uses magnetic material (such as an iron core), it may enter a state of magnetic saturation at high currents or strong magnetic fields. When the inductor saturates, its inductance L decreases significantly, causing the current to rise rapidly. To avoid magnetic saturation, ensure that the operating current does not exceed the inductor's maximum rated current.

Summary

At extremely low frequencies, the current through an inductor is primarily determined by the inductor's DC resistance RDC , and the current growth is controlled by the time constant τ=L/RDC . For a DC power source, the current will eventually stabilize at I=V/RDC . For an extremely low-frequency AC power source, the instantaneous current depends on the instantaneous voltage of the source. Additionally, the presence of other circuit components and non-ideal characteristics of the inductor (such as magnetic saturation) should be considered.

Give a tip and encourage the author!
Recommended
Low-Voltage Distribution Lines and Power Distribution Requirements for Construction Sites
Low-Voltage Distribution Lines and Power Distribution Requirements for Construction Sites
Low-voltage distribution lines refer to the circuits that, through a distribution transformer, step down the high voltage of 10 kV to the 380/220 V level—i.e., the low-voltage lines running from the substation to the end-use equipment.Low-voltage distribution lines should be considered during the design phase of substation wiring configurations. In factories, for workshops with relatively high power demand, dedicated workshop substations are often installed, where transformers supply power direc
James
12/09/2025
Three-Phase SPD: Types, Wiring & Maintenance Guide
Three-Phase SPD: Types, Wiring & Maintenance Guide
1. What Is a Three-Phase Power Surge Protective Device (SPD)?A three-phase power surge protective device (SPD), also known as a three-phase lightning arrester, is specifically designed for three-phase AC power systems. Its primary function is to limit transient overvoltages caused by lightning strikes or switching operations in the power grid, thereby protecting downstream electrical equipment from damage. The SPD operates based on energy absorption and dissipation: when an overvoltage event occ
James
12/02/2025
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Railway power systems primarily consist of automatic block signaling lines, through-feeder power lines, railway substations and distribution stations, and incoming power supply lines. They provide electricity to critical railway operations—including signaling, communications, rolling stock systems, station passenger handling, and maintenance facilities. As an integral part of the national power grid, railway power systems exhibit distinct characteristics of both electrical power engineering and
Echo
11/26/2025
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.