What is Inter Turn Fault Protection?

Encyclopedia
Field: Encyclopedia
0
China


What is Inter Turn Fault Protection?


Inter Turn Fault Definition


Inter turn faults happen when the insulation between conductors in the same stator winding slot is damaged.


Detection Methods


These faults can be detected using stator differential protection or stator earth fault protection.


Importance of Stator Inter Turn Protection


High voltage generators and modern large generators need stator inter turn protection to prevent faults.


Cross Differential Method


Ross differential methods is most common among them. In this scheme the winding for each phase is divided into two parallel paths.


Each path is fitted with identical current transformers (CTs), and their secondaries are cross-connected. This cross-connection is because the currents at the primary of both CTs are entering, unlike differential protection of transformer where current enters from one side and exits the other.


A differential relay and series stabilizing resistor are connected across the CT secondary loop. If an inter turn fault occurs in any path of the stator winding, it creates an imbalance in the CT secondary circuits, triggering the 87 differential relay. Cross differential protection should be applied individually to each.


374a28fd41509f4d50616abb5189ae6a.jpeg


Alternative Protection Scheme


This scheme provides complete protection against internal faults of all synchronous machines irrespective of the type of the winding employed or the kind of methods for connection. An internal fault in the stator winding generates second harmonic current, included in the field winding and exciter circuits of the generator. This current can be applied to a sensitive polarized relay via a CT and filter circuit.


The scheme operation is controlled by a direction of negative phase sequence relay, in order to prevent operation during external unbalanced faults or asymmetrical load conditions. Should there be any asymmetry external to the generator unit zone, the negative phase sequence relay prevents a complete shutdown, only allowing the main circuit breaker to be tripped, to prevent the rotor damage due to the over rating effects of second harmonic currents.

 

e160679f545c1120961f89916c87e186.jpeg 

Give a tip and encourage the author!
Recommended
What are the principles of forced re-energization of transmission lines?
Principles of Forced Re-energization of Transmission LinesRegulations for Forced Re-energization of Transmission Lines Correctly select the forced re-energization end of the line. If necessary, change the connection configuration before forced re-energization, taking into account the reduction of short-circuit capacity and its impact on grid stability. There must be a transformer with its neutral point directly grounded on the busbar at the forced re-energization end. Pay attention to the impact
Edwiin
09/04/2025
Analysis of Accident Handling in Transmission Lines
Analysis of Transmission Line Fault HandlingAs a fundamental component of the power grid, transmission lines are widely distributed and numerous, often exposed to diverse geographical and climatic conditions, making them highly susceptible to faults. Common causes include overvoltage, pollution flashover, insulation damage, tree encroachment, and external damage. Line tripping is one of the most frequent faults in power plant and substation operations, with fault types including single-phase-to-
Leon
09/04/2025
The difference between transmission and distribution lines
Transmission lines and distribution lines are both used to carry electrical power from one location to another. However, they differ significantly in key aspects such as primary function, voltage levels, phase configuration, and conductor placement. These differences are essential for understanding their distinct roles in the power system.The Difference Between Transmission and Distribution Line is given below in the tabulated form.Electricity generation is a critical component of the power syst
Edwiin
09/04/2025
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
Related Products
  • 550kV 740kV Gas Insulated Switchgear HV (GIS)
  • MNS type 380V 660V LV withdrawable switchgear
  • 12kV Solid Insulated Ring Main Unit Switchgear
  • 40.5(72.5)kV Hybrid Type HV Gas-Insulated Switchgear(GIS)
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.