35kV Three-phase Epoxy Cast Dry Distribution Transformer

  • 35kV Three-phase Epoxy Cast Dry Distribution Transformer
  • 35kV Three-phase Epoxy Cast Dry Distribution Transformer

Key attributes

Brand Vziman
Model NO. 35kv Three-phase Epoxy Cast Dry Distribution Transformer
Rated capacity 2000kVA
Voltage grade 35KV
Series Dry Distribution Transformer
Description

Product overview:

  •  Lower loss, more energy saving, 30% energy saving than SCB11 transformer loss.

  • Actual measurement is better than GB and IEC standards, CB, CCC, KEMA SASO and other certification.

  • Better safety excellent fire performance, F1 class.

  • High lightning resistance level (175kV for 35kV products).

  • Equipped with perfect temperature protection control system, it can operate at 120% rated load under forced air cooling condition.

  • Global operation verified high reliability, has been exported to more than 50 countries and regions.

  • Mainly used in 35KV urban distribution network, industrial and mining enterprises and civil building power supply and distribution system.

  • Products are mainly exported to Southeast Asia, the Middle East, Africa, South America and other countries and regions.

  • Implementation standard: IEC 60076 series, GB1094 series, GB/T6451-2008.

  • The shell material is aluminum alloy, cold rolled steel plate, stainless steel, etc. (protection grade IP20, IP23, etc.))

Product advantages

Leading technology

  • High pressure copper tape winding technology, flame retardant formula vacuum pouring.

  • Low pressure copper foil winding technology, thermosetting epoxy prepreg cloth insulation.

  • High quality iron core 45° full oblique joint step laminated structure.

The iron core

  • The core is made of high quality cold rolled grain oriented silicon steel sheet insulated by mineral oxide.

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • Apply class F or CLASS H core paint on the surface of assembled cores to prevent corrosion and rust.

Low voltage winding

  • The low voltage winding is made of high quality copper foil.

  • Insulated by thermosetting epoxy preimpregnated cloth.

  • Winding ends are insulated with thermosetting epoxy preimpregnated cloth.

  • Excellent insulation resistance.

  • Very good resistance to radial stress caused by short circuit.

  • The outgoing terminal of the low-voltage winding is tinned copper bar.

  • The whole winding is heated in the oven to 140°C and polymerized for 4 hours. It has excellent corrosion resistance of industrial gas.

High voltage winding

  • Made of insulated copper wire and using the patented technology of Hengfengyou Electric.

  • For small volume products, the high voltage winding uses a linear voltage gradient from top to bottom.

  • For products with large capacity, the high voltage winding is made by "tape winding" technology.

  • The application of these methods makes the electric field between adjacent conductors very low.

  • Transformer structure is reliable during normal operation and transportation.

High quality material

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • Huntsman Epoxy resin (including flame retardant filler).

Product parameters
35kv Three-phase Epoxy Cast Dry Distribution Transformer-1.png

Ordering instructions

  • Main parameters of transformer (voltage, capacity, loss and other main parameters.

  • Transformer operating environment (altitude, temperature, humidity, location, etc.

  •  Other customization requirements (coupling groups, colors, oil pillows, etc.

  • The minimum order quantity is 1 sets, worldwide delivery within 7 days.

  • Normal delivery period of 30 days, worldwide fast delivery.

What is the epoxy casting process for the windings and core z of the transformer?

Manufacture of Windings and Iron Cores:

Windings Manufacture:

  • Use a wire winding machine to wind the copper wires into the required shapes and number of layers.

  • Ensure the uniformity and compactness of the windings.

  • Add insulating materials, such as insulating paper or insulating tape, between each layer of copper wires.

Iron Core Manufacture:

  • Use a silicon steel sheet laminating device to laminate the silicon steel sheets into an iron core.

  • Ensure the flatness and compactness of the iron core.

  • Conduct necessary pre-treatments on the iron core, such as deburring and cleaning.

Assembly:

Assembling Windings and Iron Cores:

  • Assemble the windings and the iron core together, ensuring the correct positions and connections between them.

  • Use temporary fixing devices (such as clamps) to fix the windings and the iron core to prevent displacement during the casting process.


Documentation Resource Library

Restricted
Vziman IEC/ ANSI Dry-Type Power transformer selection catalog
Catalogue
English
Consulting

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Surge Arrester Structure and Electrical Testing Technology
    1.Critical Role of Surge Arresters in Power System Overvoltage ProtectionThe surge arrester serves as the primary line of defense against overvoltage in power systems. Its operational status directly determines the insulation safety of major equipment such as transformers, motors, and switchgear. Zinc Oxide Arresters (MOA), with their superior non-linear voltage-current characteristics, have become the most widely used protective devices in modern grids. Deeply understanding their internal confi
    04/11/2026
  • Comprehensive Comparison of Energy Efficiency Standards for Three-Phase Power Transformers
    1. OverviewThe national standard for "Minimum Allowable Values of Energy Efficiency and the Energy Efficiency Grades for Power Transformers" has undergone a major update. The new version, GB 20052-2024, was issued on April 29, 2024, and is scheduled for official implementation on February 1, 2025, at which time it will fully replace the current GB 20052-2020.This revision aligns with China's "Dual Carbon" goals, aiming to further enhance the energy efficiency of power equipment, phase out outdat
    04/10/2026
  • Technical Comparison of Recloser PMA vs SOM Mechanisms
    As devices that frequently break fault currents, recloser operating mechanisms must meet requirements for high consistency, extremely short opening and closing times, and tens of thousands of mechanical cycles. Traditional spring-operated mechanisms (SOM) achieve operation through mechanical energy storage and complex linkage systems, whereas permanent magnetic actuators (PMA) introduce direct electromagnetic drive and magnetic latching. As engineers with 29 years of experience, we know that mec
    04/08/2026
  • 110kV Transformer Partial Discharge Ultrasonic Localization Technology
    Importance of Partial Discharge Localization in 110kV Live Line TestingPartial discharge (PD) serves as a critical early warning sign of insulation deterioration within 110kV transformers. If left undetected, persistent discharge can cause irreversible carbonization of the oil-paper insulation, eventually leading to catastrophic dielectric failure. In the context of 110kV substation maintenance, ultrasonic localization has emerged as a primary diagnostic tool due to its high immunity to electrom
    04/08/2026
  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.