How Input Voltage Affects the Current Through a Load Resistor in an Ideal Transformer

An ideal transformer is one that assumes no energy losses (such as copper loss or iron loss). Its primary function is to change the levels of voltage and current while ensuring that the input power equals the output power. The operation of an ideal transformer is based on the principle of electromagnetic induction, and there is a fixed turns ratio n between the primary and secondary coils, given by n=N2 /N1, where N1 is the number of turns in the primary coil, and N2 is the number of turns in the secondary coil.Impact of Input Voltage on Load Resistor Current When an input voltage V1 is applied to the primary coil of an ideal transformer, according to the turns ratio n, it induces a corresponding output voltage V2 in the secondary coil, which can be expressed by the following formula:

image.png

If the secondary coil is connected to a load resistor RL , then the current I2 flowing through this load resistor can be calculated using Ohm's Law:

image.png

Substituting the expression for V2 into the above equation gives:

image.png

From this equation, it can be seen that for a given turns ratio n and load resistance RL, the secondary current I2 is directly proportional to the input voltage V1. This means:

  • When the input voltage V1 increases, if the turns ratio n and load resistance RL remain constant, the secondary current I2 will also increase accordingly.

  • When the input voltage V1 decreases, under the same conditions, the secondary current I2 will decrease.

It is important to note that in an ideal transformer, the input power P1 equals the output power P2, so:

image.png

Here, I1 is the current in the primary coil. Since V2=V1×n, then I2=I1/n, indicating that the primary current
   
I1 is inversely proportional to the secondary current I2, both of which depend on the input voltage V1.

In summary, the input voltage V1 directly influences the current I2 flowing through the load resistor RL in an ideal transformer, and this effect is realized through the transformer’s turns ratio n.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.