10kV High-voltage series reactors for Serial Connection

  • 10kV High-voltage series reactors for Serial Connection

Key attributes

Brand POWERTECH
Model NO. High-voltage series reactors
Rated voltage 10kV
Capacity 5KVar
Series CKSC

Product descriptions from the supplier

Description

 Function:

The series reactor is connected in series with the shunt capacitor group, which has the functions of compensating the reactive power of the power grid, improving the power factor, suppressing the harmonic current, limiting the closing inrush current, etc., and is suitable for the power system, electrified railway, metallurgy, petrochemical and other high fire protection requirements. Places such as urban grid substations, underground substations and microcomputer-controlled substations with limited electromagnetic interference requirements and installation space.

Parameters to be provided when ordering:

  •  The rated capacity of the reactor.

  • System rated voltage and frequency.

  •  Capacitor terminal voltage.

  •  Rated reactance or reactance rate of reactor.

  •  Rated current and continuous current.

  • Dynamic and thermal stability current and duration.

  • Other special requirements.

企业微信截图_17331878222488.png

Standard:

  • IEC289-88 "reactor".

  • GB10229-88 "Reactor".

  • JB5346-98 "Reactor".

  • DL462-92 "Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors".

Structural characteristics:

  •  The reactor is divided into three phase and single phase, both of which are epoxy casting.

  • The core is made of low-loss cold-rolled oriented silicon steel sheet, which is punched and sheared by a high-speed punch, which has small burrs, regular uniformity, and neat and beautiful lamination, so as to ensure the performance of low temperature rise and low noise during the operation of the reactor.

  •  The coil is epoxy casting, the coil is reinforced by laying epoxy glass mesh cloth inside and outside, and the F-class epoxy casting system is used to pour in a vacuum state, the coil not only has good insulation performance, but also has good mechanical strength, and can withstand large current impact and cold and hot shock without cracking.

  •  The epoxy casting coil does not absorb water, has low partial discharge, and can operate safely under harsh environmental conditions.

  • The upper and lower ends of the coil are made of epoxy cushion blocks and silicone rubber shockproof pads, which effectively reduce the vibration of the coil during operation.

Conditions for the use:

  • The altitude does not exceed 2000 meters.

  •  The operating environment temperature is -25°C~+40°C, and the relative humidity is not more than 93%.

  • There are no harmful gases around, no flammable and explosive materials.

  •  The surrounding environment should have good ventilation conditions.

  •  Insulation Grade: Class F, Reactor Noise: ≤45dB

  • Overload capacity: continuous operation at ≤ 1.35 times

  • The uneven transverse between the phases of the reactor is not more than ±3%, and the inductance error is controlled within +3%.

  •  Insulation level: LI75AC35kV

 

What is the principle of inductance characteristics of a reactor?

Inductive Characteristics Principle:

  • Reactors operate based on the principle of electromagnetic induction. When current flows through the windings, a magnetic field is generated in the core. According to Lenz's Law, this magnetic field opposes the change in current, thereby limiting the rate of change of the current.

  • For example, in an alternating current (AC) circuit, where the current is continuously changing, the inductance of the reactor causes the current to lag behind the voltage in phase. This phase shift results in the generation of reactive power, which can be used for reactive power compensation in the circuit.

  • In a direct current (DC) circuit, reactors can smooth out the current, reducing fluctuations and providing a more stable current flow.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 580000m² Total staff: Highest Annual Export(usD): 120000000
Workplace: 580000m²
Total staff:
Highest Annual Export(usD): 120000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Core Value and Innovative Applications of 12kV Medium Voltage Switchgear in Smart Substations​
    With the Rapid Development of Smart Grids and the Integration of Renewable Energy Medium Voltage (MV) Switchgear, as the core power distribution equipment in substations, directly determines the stability of the power system through its reliability, intelligence, and space efficiency. This article delves into the key technologies, scenario-specific solutions, and practical benefits of Medium Voltage Switchgear in substations.Core Requirements for Substation ScenariosHigh Reliability Requirements
    06/12/2025
  • Withdrawable 12kV Medium Voltage Switchgear: The Indispensable Pivot of Flexibility and Safety in Smart Grids
    At the core of medium-voltage power distribution systems in industrial facilities, commercial complexes, and data centers, switchgear acts as a silent commander, governing the lifeline of electrical flow. Among various solutions, ​Withdrawable Switchgear​has become synonymous with reliability in modern MV systems due to its unique design philosophy. Compared to fixed switchgear, its "withdrawable" feature delivers compelling advantages, setting new benchmarks for ​operational efficiency​and ​per
    06/12/2025
  • Core Dilemma in Southeast Asia 12kV Medium Voltage Switchgear​
    Southeast Asia’s rapidly growing power demand (GDP growth >5% annually) combined with extreme climatic conditions—high temperature, humidity, and salt spray corrosion—necessitates balancing lifecycle costs with climate resilience in switchgear selection. This article analyzes the optimal cost-performance solutions between GIS and AIS.​I. GIS vs. AIS Cost Comparison Model (Southeast Asia Context)​​​1. Initial Investment Costs​2. Long-Term Operational Costs​​GIS Advantages:Ext
    06/12/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.