10kV High-voltage series reactors for Serial Connection
discuss personally
Model
CKSC-10/6-6
CKSC-10/5-6
CKSC-10/3-6
Basic info
Brand Wone
Model NO. High-voltage series reactors
Rated voltage 10kV
Capacity 6KVar
Series CKSC
Product Detail

 Function:

The series reactor is connected in series with the shunt capacitor group, which has the functions of compensating the reactive power of the power grid, improving the power factor, suppressing the harmonic current, limiting the closing inrush current, etc., and is suitable for the power system, electrified railway, metallurgy, petrochemical and other high fire protection requirements. Places such as urban grid substations, underground substations and microcomputer-controlled substations with limited electromagnetic interference requirements and installation space.

Parameters to be provided when ordering:

  •  The rated capacity of the reactor.

  • System rated voltage and frequency.

  •  Capacitor terminal voltage.

  •  Rated reactance or reactance rate of reactor.

  •  Rated current and continuous current.

  • Dynamic and thermal stability current and duration.

  • Other special requirements.

企业微信截图_17331878222488.png

Standard:

  • IEC289-88 "reactor".

  • GB10229-88 "Reactor".

  • JB5346-98 "Reactor".

  • DL462-92 "Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors".

Structural characteristics:

  •  The reactor is divided into three phase and single phase, both of which are epoxy casting.

  • The core is made of low-loss cold-rolled oriented silicon steel sheet, which is punched and sheared by a high-speed punch, which has small burrs, regular uniformity, and neat and beautiful lamination, so as to ensure the performance of low temperature rise and low noise during the operation of the reactor.

  •  The coil is epoxy casting, the coil is reinforced by laying epoxy glass mesh cloth inside and outside, and the F-class epoxy casting system is used to pour in a vacuum state, the coil not only has good insulation performance, but also has good mechanical strength, and can withstand large current impact and cold and hot shock without cracking.

  •  The epoxy casting coil does not absorb water, has low partial discharge, and can operate safely under harsh environmental conditions.

  • The upper and lower ends of the coil are made of epoxy cushion blocks and silicone rubber shockproof pads, which effectively reduce the vibration of the coil during operation.

Conditions for the use:

  • The altitude does not exceed 2000 meters.

  •  The operating environment temperature is -25°C~+40°C, and the relative humidity is not more than 93%.

  • There are no harmful gases around, no flammable and explosive materials.

  •  The surrounding environment should have good ventilation conditions.

  •  Insulation Grade: Class F, Reactor Noise: ≤45dB

  • Overload capacity: continuous operation at ≤ 1.35 times

  • The uneven transverse between the phases of the reactor is not more than ±3%, and the inductance error is controlled within +3%.

  •  Insulation level: LI75AC35kV

 

What is the principle of inductance characteristics of a reactor?

Inductive Characteristics Principle:

  • Reactors operate based on the principle of electromagnetic induction. When current flows through the windings, a magnetic field is generated in the core. According to Lenz's Law, this magnetic field opposes the change in current, thereby limiting the rate of change of the current.

  • For example, in an alternating current (AC) circuit, where the current is continuously changing, the inductance of the reactor causes the current to lag behind the voltage in phase. This phase shift results in the generation of reactive power, which can be used for reactive power compensation in the circuit.

  • In a direct current (DC) circuit, reactors can smooth out the current, reducing fluctuations and providing a more stable current flow.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
James
07/16/2025
A Quick Verification Method for Low-Voltage Current Transformers
A Quick Verification Method for Low-Voltage Current Transformers
To ensure safe operation of the power system, power equipment operation must be monitored/measured. General devices can’t connect to primary high - voltage equipment directly; instead, large primary currents are scaled down for current transformation, electrical isolation, and use by measurement/protection devices. For AC large - current measurement, conversion to a unified current eases secondary instrument use.Current transformers split into measurement - and protection - type, with accu
Oliver Watts
07/16/2025
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
Research on Low - Voltage Anti - DC Current Transformer and Detection Device
1. Overview of Components and IssuesTA (low-voltage current transformer) and electric energy meters are key components of low-voltage electric energy metering. The load current of such meters is no less than 60A. Electric energy meters vary in type, model, and anti-DC performance, and are connected in series in the metering device. Due to the lack of anti-DC capability, they suffer from metering errors under DC component loads, usually caused by non-linear loads. With the increasing use of DC or
Dyson
07/16/2025
Anti - Theft Device for Low - Voltage Current Transformers
Anti - Theft Device for Low - Voltage Current Transformers
1. Innovation BackgroundWith the progress of society and economic development, the electricity demand of power users is expanding increasingly. Lawbreakers, aiming to save electricity costs and pursue high profits, gradually use high - tech methods to steal electricity, causing huge economic losses to power supply enterprises. Currently, popular electricity theft methods in the market include illegally opening the wiring cover of low - voltage transformers in electric energy metering boxes, alte
Dyson
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!