• 10kV High-voltage series reactors for Serial Connection
10kV High-voltage series reactors for Serial Connection
discuss personally
Model
CKSC-10/6-6
CKSC-10/5-6
CKSC-10/3-6
Basic info
Brand Wone
Model NO. High-voltage series reactors
Rated voltage 10kV
Capacity 3KVar
Series CKSC
Product Detail

 Function:

The series reactor is connected in series with the shunt capacitor group, which has the functions of compensating the reactive power of the power grid, improving the power factor, suppressing the harmonic current, limiting the closing inrush current, etc., and is suitable for the power system, electrified railway, metallurgy, petrochemical and other high fire protection requirements. Places such as urban grid substations, underground substations and microcomputer-controlled substations with limited electromagnetic interference requirements and installation space.

Parameters to be provided when ordering:

  •  The rated capacity of the reactor.

  • System rated voltage and frequency.

  •  Capacitor terminal voltage.

  •  Rated reactance or reactance rate of reactor.

  •  Rated current and continuous current.

  • Dynamic and thermal stability current and duration.

  • Other special requirements.

企业微信截图_17331878222488.png

Standard:

  • IEC289-88 "reactor".

  • GB10229-88 "Reactor".

  • JB5346-98 "Reactor".

  • DL462-92 "Technical Conditions for Ordering Series Reactors for High Voltage Shunt Capacitors".

Structural characteristics:

  •  The reactor is divided into three phase and single phase, both of which are epoxy casting.

  • The core is made of low-loss cold-rolled oriented silicon steel sheet, which is punched and sheared by a high-speed punch, which has small burrs, regular uniformity, and neat and beautiful lamination, so as to ensure the performance of low temperature rise and low noise during the operation of the reactor.

  •  The coil is epoxy casting, the coil is reinforced by laying epoxy glass mesh cloth inside and outside, and the F-class epoxy casting system is used to pour in a vacuum state, the coil not only has good insulation performance, but also has good mechanical strength, and can withstand large current impact and cold and hot shock without cracking.

  •  The epoxy casting coil does not absorb water, has low partial discharge, and can operate safely under harsh environmental conditions.

  • The upper and lower ends of the coil are made of epoxy cushion blocks and silicone rubber shockproof pads, which effectively reduce the vibration of the coil during operation.

Conditions for the use:

  • The altitude does not exceed 2000 meters.

  •  The operating environment temperature is -25°C~+40°C, and the relative humidity is not more than 93%.

  • There are no harmful gases around, no flammable and explosive materials.

  •  The surrounding environment should have good ventilation conditions.

  •  Insulation Grade: Class F, Reactor Noise: ≤45dB

  • Overload capacity: continuous operation at ≤ 1.35 times

  • The uneven transverse between the phases of the reactor is not more than ±3%, and the inductance error is controlled within +3%.

  •  Insulation level: LI75AC35kV

 

What is the principle of inductance characteristics of a reactor?

Inductive Characteristics Principle:

  • Reactors operate based on the principle of electromagnetic induction. When current flows through the windings, a magnetic field is generated in the core. According to Lenz's Law, this magnetic field opposes the change in current, thereby limiting the rate of change of the current.

  • For example, in an alternating current (AC) circuit, where the current is continuously changing, the inductance of the reactor causes the current to lag behind the voltage in phase. This phase shift results in the generation of reactive power, which can be used for reactive power compensation in the circuit.

  • In a direct current (DC) circuit, reactors can smooth out the current, reducing fluctuations and providing a more stable current flow.


Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!