What is Conservator Tank of Transformer?

Encyclopedia
Field: Encyclopedia
0
China

What is Conservator Tank of Transformer?

Conservator Tank Definition

A conservator tank is a cylindrical container on a transformer, providing space for the oil to expand and contract.

Function

The conservator tank allows transformer oil to expand when hot and contract when cool, preventing overflow and ensuring efficient operation.

Construction

The conservator tank is a cylindrical oil container closed at both ends. It has a large inspection cover on each side for easy maintenance and cleaning.

Conservator pipe, i.e. pipe comes from main transformer tank, is projected inside the conservator from bottom portion. Head of the conservator pipe inside the conservator is provided with a cap. This pipe is projected as well as provided with a cap because this design prevent oil sludge and sediment to enter into main tank from conservator. Generally silica gel breather fixing pipe enters into the conservator from top. If it enters from bottom, it should be projected well above the level of oil inside the conservator. This arrangement ensure that oil does not enter the silica gel breather even at highest operating level.

d6f60c30-32fa-4096-8f1a-b0052580b1c6.jpg

Working of Conservator Tank

When the insulating oil expands due to load and temperature, it partially fills the conservator tank, pushing out air through the breather. When the load decreases or the temperature drops, the oil contracts, allowing outside air to enter the conservator tank of transformer through the silica gel breather.

Atmoseal Type Conservator

In this type conservator of transformer, an air cell made of NBR material is fitted inside the conservator reservoir. The silica gel breather is connected at the top of this air cell. The oil level in the power transformer rises and falls according to this air cell deflated and inflated. When the air cell gets deflated the air inside the air cell comes out via breather and on the other hand if the cell is inflated the outside air comes in through breather.

This arrangement prevents direct contact of oil with air, thereby reduces ageing affect of oil.

7ea62de3-b281-45e7-a3cf-87011a22a702.jpg

The space available outside the cell in conservator tank is totally filled by oil. Air vents are provided on the top of the conservator for venting accumulated air outside the air cell.

The pressure inside the air cell must be maintained 1.0 PSI.

Diaphragm Sealed Conservator

This conservator uses a diaphragm to keep oil and air separate, preventing gas bubble formation that can cause insulation failure.

ba40f31a-21d7-4e35-af31-b853d1f3968e.jpg

Sum up

The oil storage tank is essential to the normal operation of the oil-immersed transformer, and reasonable maintenance and maintenance can ensure the safety and reliability of the transformer.

Give a tip and encourage the author!
Recommended
What Are Common Faults in Power Distribution Lines? A Complete Guide to Operational Challenges and Solutions
1 Overview of Power Transmission and Distribution Lines1.1 Key Characteristics of Power Transmission and Distribution Lines High Maintenance Difficulty: This is mainly due to the wide area covered by power transmission and distribution lines, the harsh terrain of the laying areas, and the impact of seasonal climate changes, all of which contribute to difficult maintenance. High Requirement for Operational Reliability: The reliable operation of power transmission and distribution lines is closely
Leon
09/06/2025
A Complete Guide to PV Power Plant Overvoltage Fault: Causes, Risks, and Systematic Solutions
I. What is a Grid Voltage Overvoltage Fault?Grid voltage overvoltage refers to a phenomenon in power systems or circuits where the voltage exceeds the normal operating range.Generally, under power frequency, if the RMS (Root Mean Square) value of the AC voltage rises to more than 10% above the rated value and lasts for more than 1 minute, it can be determined as a grid voltage overvoltage fault.For example, in China’s common 380V three-phase grid system, if the voltage exceeds 418V and persists
Edwiin
09/06/2025
Transforming Power: The Future of Electric Transformers
Transformers are the "unsung heroes" of the modern world. These seemingly unremarkable devices, either hidden on utility poles or installed in substations, play an indispensable role in the power grid system—it is through them that electrical energy can be efficiently converted, transmitted, and utilized. Today, as humanity stands at the crossroads of an accelerating transformation in the energy landscape, recognizing the transformative potential of transformers and exploring how they will shape
Vziman
09/06/2025
Relay Protection Basics: Types of Transmission Line Faults and Fundamental Protection Schemes
1. Types of Faults on Power LinesPhase-to-Phase Faults: Three-phase short circuit Two-phase short circuitGround Faults: Single-phase to ground fault Two-phase to ground fault Three-phase to ground fault2. Definition of Relay Protection DevicesWhen an abnormality or fault occurs in a component of a power system, relay protection devices are those that can quickly and selectively isolate the faulty or abnormal component from the system, ensuring the continued normal operation of the remaining heal
Leon
09/05/2025
Seed Inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.