What is Conservator Tank of Transformer?

Encyclopedia
Field: Encyclopedia
0
China

What is Conservator Tank of Transformer?

Conservator Tank Definition

A conservator tank is a cylindrical container on a transformer, providing space for the oil to expand and contract.

Function

The conservator tank allows transformer oil to expand when hot and contract when cool, preventing overflow and ensuring efficient operation.

Construction

The conservator tank is a cylindrical oil container closed at both ends. It has a large inspection cover on each side for easy maintenance and cleaning.

Conservator pipe, i.e. pipe comes from main transformer tank, is projected inside the conservator from bottom portion. Head of the conservator pipe inside the conservator is provided with a cap. This pipe is projected as well as provided with a cap because this design prevent oil sludge and sediment to enter into main tank from conservator. Generally silica gel breather fixing pipe enters into the conservator from top. If it enters from bottom, it should be projected well above the level of oil inside the conservator. This arrangement ensure that oil does not enter the silica gel breather even at highest operating level.

d6f60c30-32fa-4096-8f1a-b0052580b1c6.jpg

Working of Conservator Tank

When the insulating oil expands due to load and temperature, it partially fills the conservator tank, pushing out air through the breather. When the load decreases or the temperature drops, the oil contracts, allowing outside air to enter the conservator tank of transformer through the silica gel breather.

Atmoseal Type Conservator

In this type conservator of transformer, an air cell made of NBR material is fitted inside the conservator reservoir. The silica gel breather is connected at the top of this air cell. The oil level in the power transformer rises and falls according to this air cell deflated and inflated. When the air cell gets deflated the air inside the air cell comes out via breather and on the other hand if the cell is inflated the outside air comes in through breather.

This arrangement prevents direct contact of oil with air, thereby reduces ageing affect of oil.

7ea62de3-b281-45e7-a3cf-87011a22a702.jpg

The space available outside the cell in conservator tank is totally filled by oil. Air vents are provided on the top of the conservator for venting accumulated air outside the air cell.

The pressure inside the air cell must be maintained 1.0 PSI.

Diaphragm Sealed Conservator

This conservator uses a diaphragm to keep oil and air separate, preventing gas bubble formation that can cause insulation failure.

ba40f31a-21d7-4e35-af31-b853d1f3968e.jpg

Sum up

The oil storage tank is essential to the normal operation of the oil-immersed transformer, and reasonable maintenance and maintenance can ensure the safety and reliability of the transformer.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.