BSMJ Self-healing low voltage shunt capacitor

  • BSMJ Self-healing low voltage shunt capacitor

Key attributes

Brand Switchgear parts
Model NO. BSMJ Self-healing low voltage shunt capacitor
Rated voltage 0.25Kv
Rated frequency 50/60Hz
Series BSMJ

Product descriptions from the supplier

Description

Application

Self healing low-voltage parallel power capacitors are suitable for 50Hz and 60Hz power systems, mainly used to improve power factor, reduce reactive power loss, improve voltage quality, increase transformer capacity, etc. They are suitable for low-voltage reactive power compensation cabinets, general distribution cabinets, and modular distribution cabinets. The specific applicable cabinets are as follows:

GGJ, GGD (with compensation unit), GCK/GCS/MNS (compensation module), XL-21 (customized compensation type)

This product meets the standard: GB/T 12747-2004, IEC60831-1996

Main Technical Date

Model Rated Volt. (KV) Rated Capacity (Kvar) Rated Capacity (μF) Rated Current (A)
0.18-10-1 0.18 10 983.0 55.6
0.18-15-1 0.18 15 1475.0 83.3
0.18-20-1 0.18 20 1966.0 111.0
0.18-25-1 0.18 25 2458.0 139.0
0.25-5-1 0.25 5 255.0 20
0.25-7.5-1 0.25 7.5 382.0 30
0.25-10-1 0.25 10 510.0 40
0.25-15-1 0.25 15 764.0 60
0.25-20-1 0.25 20 1019.0 80
0.25-25-1 0.25 25 1274.0 100
0.25-30-1 0.25 30 1529.0 120
0.4-10-1 0.4 10 198.9 25
0.4-12-1 0.4 12 238.7 30
0.4-15-1 0.4 15 298.4 37.5
0.4-16-1 0.4 16 318.3 40
0.4-18-1 0.4 18 358.1 45.0
0.4-20-1 0.4 20 397.9 50
0.4-25-1 0.4 25 497.4 62.5
0.4-30-1 0.4 30 596.8 75
0.4-35-1 0.4 35 696.3 87.5
0.4-40-1 0.4 40 796.2 100
0.4-45-1 0.4 45 895.2 112.5
0.4-50-1 0.4 50 995.2 125
0.4-60-1 0.4 60 1194.3 150
0.45-10-1 0.45 10 157.2 22.2
0.45-12-1 0.45 12 188.6 26.7
0.45-15-1 0.45 15 235.8 33.3
0.45-16-1 0.45 16 251.5 35.6
0.45-18-1 0.45 18 282.9 40
0.45-20-1 0.45 20 314.4 44.4
0.45-25-1 0.45 25 393.2 55.6
0.45-30-1 0.45 30 471.8 66.7
0.45-35-1 0.45 35 550.2 77.8
0.45-40-1 0.45 40 629.1 88.9
0.45-45-1 0.45 45 707.4 100.0
0.45-50-1 0.45 50 786.3 111.1
0.45-60-1 0.45 60 943.6 133.3
Model H(mm) terminal Drawing No.
0.18-10-1 220 M6 2
0.18-15-1 220 M8 3
0.18-20-1 220 M8 3
0.18-25-1 290 M8×2 3
0.25-5-1 130 M6 1
0.25-7.5-1 180 M8 1
0.25-10-1 210 M8 1
0.25-15-1 260 M8 2
0.25-20-1 330 M10 2
0.25-25-1 345 M10 2
0.25-30-1 220 2×M10 3
0.4-10-1 180 M6 2
0.4-12-1 180 M6 2
0.4-15-1 210 M8 2
0.4-16-1 210 M8 2
0.4-18-1 245 M8 2
0.4-20-1 245 M8 2
0.4-25-1 210 M8 2
0.4-30-1 260 M8 2
0.4-35-1 260 M8 2
0.4-40-1 330 M10 2
0.4-45-1 220 2×M10 2
0.4-50-1 220 2×M10 2
0.4-60-1 220 2×M10 2
0.45-10-1 180 M6 2
0.45-12-1 180 M6 2
0.45-15-1 210 M8 2
0.45-16-1 210 M8 2
0.45-18-1 210 M8 2
0.45-20-1 210 M8 2
0.45-25-1 210 M8 2
0.45-30-1 210 M8 2
0.45-35-1 260 M10 2
0.45-40-1 260 M10 2
0.45-45-1 220 M10 3
0.45-50-1 220 2×M10 3
0.45-60-1 220 2×M10 3

Note: Other special specification models supply according to user requirements

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.