36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear

  • 36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear

Key attributes

Brand ROCKWILL
Model NO. 36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear
Rated voltage 36kV
Rated frequency 50/60Hz
Series KYN61-40.5

Product descriptions from the supplier

Description

Description

KYN61-40.5( same as unigear Z3.2) air-insulated metal-clad withdrawable switchgear( hereinafter as "swit chgear") is a kind of MV switchgear.

It is designed as withdrawable module type panel, and the withdrawable part is fitted with VD4-36E, VD4-40.5 withdrawable vacuum circuit breaker manufactured by Cooper Nature company. It can also be fitted with isolation truck, PT truck, fuses truck and so on. It is applicable to three phase AC 50/60 Hz power system,

and mainly used for the transmission and distribution of electrical power and control, protection, monitoring of the circuit.

Standards and specifications

  • IEC60694 The commo n technical requirements of high voltage switchgear and controlgear.

  • IEC62271-200 A.C. metal enclosed switchgear and controlgear at the rated voltage of 1kV~52k V.

  • IEC62271-100 High voltage switchgear and controlgear-Part 100:Hi gh voltage A.C. circuit breaker.

  • GB3906 3.6~ 40.5kV alternating current metal enclosed switchgea r and controlgear.

  • GB1984 High voltage alternating current circuit breaker.

  • GB/T11022 The commo n technical requirements of high voltage switchgear and controlgear.

  • DL/T404 3.6~ 40.5kV alternating current metal enclosed switchgear and controlgear.

Service conditions:

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  •  Altitude no higher than 2500m.

  • The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

image.png

What are the structural characteristics of air-insulated metal armored withdrawable medium voltage switchgear?

Metal Clad:

  • The cabinet is made from high-quality cold-rolled steel plates, which are processed and bent using CNC equipment. It is assembled into a robust metal-clad structure using bolts, nuts, and other fasteners. This design provides high mechanical strength and protective capabilities, effectively preventing external objects from colliding with and damaging the internal electrical components.

Draw-Out Design:

  • Major electrical components, such as circuit breakers, contactors, and relays, are mounted on drawable trolleys. The trolleys and the cabinet are precisely aligned using guide rails and positioning devices, facilitating easy maintenance and repair. The trolleys can be withdrawn without interrupting power, allowing for the replacement or repair of faulty components. This significantly enhances the reliability and continuity of power supply.

Air Insulation:

  • Air is used as the insulating medium, with appropriate air gaps maintained between phases and between the phases and ground to meet insulation requirements. This design is simple and cost-effective, and it does not suffer from issues such as insulation aging or environmental pollution. However, the insulating properties of air are more susceptible to environmental factors. In harsh environments, such as high altitudes, humid conditions, or areas with heavy pollution, the insulation distance may need to be increased to ensure adequate performance.


Documentation Resource Library
Restricted
36kV 40.5kV air-insulated metal-clad withdrawable Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the key points of daily maintenance for environmentally friendly cabinets?
A:
Daily maintenance key points include: 1) Checking the gas pressure gauge regularly to ensure it is within the normal range (avoiding leakage); 2) Monitoring the dew point of insulating gas (especially in humid environments); 3) Inspecting the cabinet's appearance for corrosion, deformation, or damage; 4) Cleaning the cabinet's surface and ventilation ports to prevent dust accumulation; 5) Checking the operation status of auxiliary components (e.g., relays, meters) to ensure they work normally.
Q: How often do environmentally friendly cabinets need professional inspection?
A:
Professional inspection is recommended annually for general scenarios. For harsh environments (humid coastal areas, high-temperature industrial parks, alpine regions), semi-annual inspection is required. The inspection content includes gas tightness test, dew point detection, insulation resistance test, short-circuit breaking performance test, and component aging inspection. Comprehensive maintenance is needed every 5 years to replace aging seals and auxiliary components.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.