ROCKWILL
ROCKWILL
Wenzhou Rockwill Electric Co., Ltd.
Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
ROCKWILL
06/10/2025
SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
ROCKWILL
05/12/2025
12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
ROCKWILL
06/10/2025
SmartGrid-Ready 12kV Indoor Vacuum Circuit Breaker Solutions for Central & South Asia
Ⅰ. Central Asia Market Characteristics​1. Significant Power System Disparities with Prominent Aging Equipment​​Kazakhstan & Uzbekistan: Grid equipment exceeds operational lifespan (70%-80% aging in Kazakhstan; ~1/3 of low-voltage grids in Uzbekistan overdue), leading to high transmission losses (notably in Kazakhstan’s 12kV distribution networks).​Tajikistan: Fragile transmission networks suffer 20% energy loss. ​Turkmenistan​ faces inefficient grids and severe equipment degradation.​2
ROCKWILL
06/11/2025
In-depth Solutions for Common Issues in SF6 Ring Main Units (RMUs)
In-depth Solutions for Common Issues in SF6 Ring Main Units (RMUs)​​The stable operation of SF6 high-voltage RMUs is critical to grid safety. Addressing typical problems exposed during long-term operation, and based on industry practices and technical specifications, the following systematic solutions are proposed:​I. Comprehensive Gas Leakage Management Plan​​Phenomenon & Risk:​​SF6 gas leakage reduces dielectric strength (breakdown voltage drops by over 30% when pressure falls below 0.4MPa
ROCKWILL
08/13/2025
Rockwill Company's SF6 Circuit Breaker Solution for Substations in the Ethiopian Highlands
I.Project Background​The Ethiopian highlands feature high altitudes (average over 2,500 meters), extreme cold climates (winter temperatures as low as -30°C), and location within the seismically active East African Rift Zone. These conditions pose significant challenges to power equipment:​SF6 Liquefaction Risk: At 0.6 MPa operating pressure, SF6 gas liquefies at -25°C. Extreme cold may cause liquefaction, leading to degraded insulation and loss of arc-extinguishing capability.​Seismic Th
ROCKWILL
05/13/2025
Analysis of Two 10kV SF₆ Ring Main Unit Failures and Live Testing
Analysis of Two 10kV SF₆ Ring Main Unit Failures and Live Testing​​1 Introduction to 10kV SF₆ Ring Main Units​A 10kV SF₆ ring main unit (RMU) typically consists of a gas tank, an operating mechanism compartment, and a cable connection compartment.​Gas Tank: The most critical component, housing the load switch busbar, switch shaft, and SF₆ gas. The load switch is a three-position switch, including an isolating blade and an arc-extinguishing shield.​Operating Mechanism Compartment: The operating m
ROCKWILL
08/13/2025
10kV SF₆ Ring Main Units (RMUs) Common Fault Prevention Measures
10kV SF₆ Ring Main Units (RMUs) Common Fault Prevention Measures​During the development of urban distribution network cabling, 10kV SF₆ Ring Main Units (RMUs) (European-style), serving as ring power supply nodes, have been widely adopted due to their features such as full insulation, complete enclosure, maintenance-free operation, compact size, and flexible, convenient installation. However, as the number of RMUs in use increases, the occurrence of faults within RMUs has also gradually risen.​1
ROCKWILL
08/13/2025
Rockwill's SF6 Circuit Breaker Solution for 33kV Substations in Nigeria
Project Background​Nigeria’s tropical climate, characterized by year-round high temperatures (annual average of 35°C) and humidity (≥80%), poses significant challenges to the sealing integrity, insulation performance, and gas management of electrical equipment. Rockwill was contracted to upgrade a 33kV substation, deploying its proprietary HV-type SF6 circuit breaker to address critical issues:​Sealing Failure Risks: Accelerated aging of seals due to heat and water ingress during mo
ROCKWILL
05/13/2025
Medium Voltage Switchgear Solutions for Southeast Asia: Intelligent Power Infrastructure Adapting to Complex Environments
Southeast Asia’s power market is undergoing rapid development, driven by grid modernization and renewable energy integration. Medium Voltage (MV) switchgear—with its high reliability, extended lifespan, and adaptability to harsh conditions—has emerged as the optimal solution for modernizing regional power systems. This comprehensive strategy addresses the unique demands of key Southeast Asian markets across four dimensions: product design, certification, localized production, a
ROCKWILL
06/12/2025
Issues and Countermeasures for 10kV SF₆ Gas-Insulated Common Tank Ring Main Unit (European-Style) Cable Connections
Issues and Countermeasures for 10kV SF₆ Gas-Insulated Common Tank Ring Main Unit (European-Style) Cable Connections​With the extensive use of cable lines in urban distribution networks, 10kV SF₆ gas-insulated common tank Ring Main Units (RMUs) (European-style) are widely adopted as network nodes due to their characteristics of full insulation, complete enclosure, maintenance-free operation, compact size, and flexible installation. These European-style SF₆ common tank RMUs are suitable for coasta
ROCKWILL
08/13/2025
Intelligent Maintenance Services and Sustainable Solutions for 12kV Medium Voltage Switchgear
Ⅰ. Key Points for Medium Voltage Switchgear System Architecture Upgrade​​Integration of Eco-Friendly Insulation Technology (for Medium Voltage Switchgear)​​​SF₆-Free Solutions:​​ Adoption of dry air or AirPlus® blended gas to replace traditional SF₆ (GWP <1) in Medium Voltage Switchgear, supporting eco-gas switching throughout the equipment lifecycle (e.g., ABB PrimeGear ZX0 Switchgear).​Compact Design:​​ Modular structure reduces footprint by 25%, ideal for space-sensitive applications l
ROCKWILL
06/12/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!