• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear

  • 36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear

Key attributes

Brand ROCKWILL
Model NO. 36kV 40.5kV air-insulated metal-clad withdrawable MV Switchgear
Rated voltage 40.5kV
Rated frequency 50/60Hz
Series KYN61-40.5

Product descriptions from the supplier

Description

Description

KYN61-40.5( same as unigear Z3.2) air-insulated metal-clad withdrawable switchgear( hereinafter as "swit chgear") is a kind of MV switchgear.

It is designed as withdrawable module type panel, and the withdrawable part is fitted with VD4-36E, VD4-40.5 withdrawable vacuum circuit breaker manufactured by Cooper Nature company. It can also be fitted with isolation truck, PT truck, fuses truck and so on. It is applicable to three phase AC 50/60 Hz power system,

and mainly used for the transmission and distribution of electrical power and control, protection, monitoring of the circuit.

Standards and specifications

  • IEC60694 The commo n technical requirements of high voltage switchgear and controlgear.

  • IEC62271-200 A.C. metal enclosed switchgear and controlgear at the rated voltage of 1kV~52k V.

  • IEC62271-100 High voltage switchgear and controlgear-Part 100:Hi gh voltage A.C. circuit breaker.

  • GB3906 3.6~ 40.5kV alternating current metal enclosed switchgea r and controlgear.

  • GB1984 High voltage alternating current circuit breaker.

  • GB/T11022 The commo n technical requirements of high voltage switchgear and controlgear.

  • DL/T404 3.6~ 40.5kV alternating current metal enclosed switchgear and controlgear.

Service conditions:

  •  Ambient temperature: Maximum temperature:+40℃     Minimum temperature: -15℃.

  •  Ambient humidity: Daily average RH no more than 95%;Monthly average RH no more than 90%.

  •  Altitude no higher than 2500m.

  • The air around without any pollution of duty,smoke,ercode or flammable air,steam or salty fog.

Technical parameters:

image.png

What are the structural characteristics of air-insulated metal armored withdrawable medium voltage switchgear?

Metal Clad:

  • The cabinet is made from high-quality cold-rolled steel plates, which are processed and bent using CNC equipment. It is assembled into a robust metal-clad structure using bolts, nuts, and other fasteners. This design provides high mechanical strength and protective capabilities, effectively preventing external objects from colliding with and damaging the internal electrical components.

Draw-Out Design:

  • Major electrical components, such as circuit breakers, contactors, and relays, are mounted on drawable trolleys. The trolleys and the cabinet are precisely aligned using guide rails and positioning devices, facilitating easy maintenance and repair. The trolleys can be withdrawn without interrupting power, allowing for the replacement or repair of faulty components. This significantly enhances the reliability and continuity of power supply.

Air Insulation:

  • Air is used as the insulating medium, with appropriate air gaps maintained between phases and between the phases and ground to meet insulation requirements. This design is simple and cost-effective, and it does not suffer from issues such as insulation aging or environmental pollution. However, the insulating properties of air are more susceptible to environmental factors. In harsh environments, such as high altitudes, humid conditions, or areas with heavy pollution, the insulation distance may need to be increased to ensure adequate performance.


Documentation Resource Library
Restricted
36kV 40.5kV air-insulated metal-clad withdrawable Catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: What are the key points of daily maintenance for environmentally friendly cabinets?
A:
Daily maintenance key points include: 1) Checking the gas pressure gauge regularly to ensure it is within the normal range (avoiding leakage); 2) Monitoring the dew point of insulating gas (especially in humid environments); 3) Inspecting the cabinet's appearance for corrosion, deformation, or damage; 4) Cleaning the cabinet's surface and ventilation ports to prevent dust accumulation; 5) Checking the operation status of auxiliary components (e.g., relays, meters) to ensure they work normally.
Q: How often do environmentally friendly cabinets need professional inspection?
A:
Professional inspection is recommended annually for general scenarios. For harsh environments (humid coastal areas, high-temperature industrial parks, alpine regions), semi-annual inspection is required. The inspection content includes gas tightness test, dew point detection, insulation resistance test, short-circuit breaking performance test, and component aging inspection. Comprehensive maintenance is needed every 5 years to replace aging seals and auxiliary components.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
  • Application of Intelligent Solid Insulated Ring Main Units (SIRMUs) in the Qinzhou Distribution Network
    1 IntroductionCoastal regions face environmental challenges including heavy rainfall, lightning, high temperatures, high humidity, and high salt spray corrosion. To ensure the safety of urban distribution grids in such environments, minimize power outages caused by equipment maintenance, and prevent accidents due to equipment end-of-life and other factors affecting grid security, we have researched the use of a new type of Solid Insulated Ring Main Unit (SIRMU). This SIRMU offers long lifespan,
    08/15/2025
  • SF₆ Ring Main Units (RMUs) and Urban Grid Renovation
    Overview​Older distribution networks are primarily radial in structure, with most incoming and outgoing lines being overhead lines. The switching equipment typically consists of air-insulated vacuum circuit breakers or minimal-oil circuit breakers. These networks suffer from frequent faults, high operating costs, and prolonged, widespread power outages in the event of a failure, significantly hindering economic development.With rapid economic growth and the implementation of urban grid renovatio
    08/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.