40.5kV 44kV 45kV 46kV 66kV The compact Solid Insulated Metal-Enclosed Ring Main Unit/ Switchgear

  • 40.5kV 44kV 45kV 46kV 66kV The compact Solid Insulated Metal-Enclosed Ring Main Unit/ Switchgear

Key attributes

Brand ROCKWILL
Model NO. 40.5kV 44kV 45kV 46kV 66kV The compact Solid Insulated Metal-Enclosed Ring Main Unit/ Switchgear
Rated voltage 40.5kV
Rated frequency 50/60Hz
Series CKSS

Product descriptions from the supplier

Description
Description

The compact solid insulated ring main unit is a fully insulated, fully sealed, maintenance-free solid insulated vacuum switchgear that does not use SF6 gas. All high-voltage live parts are molded with epoxy resin material with excellent insulation performance, and the vacuum interrupter, main conductive circuit, insulating support, etc. are organically combined into a whole, and the functional units are connected by a fully insulated solid bus bar. Therefore, the entire switchgear is not affected by the external environment, which can ensure the reliability of the operation of the device and the safety of the operator.

This product is suitable for 12kV, 50Hz three-phase AC power distribution system, used for ring network power supply or terminal power supply, especially suitable for subway, chemical industry, petroleum, underground power distribution room of building, etc., where the site is small, the environment is harsh, and maintenance-free is required Electric places can also be used in outdoor pre-installed substations, outdoor box-type switch stations and other equipment, and can be equipped with protection devices, communication modules, and backup power sources to realize power distribution automation.

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

Product category

According to the switch type, it is divided into load switch with grounding assembly (referred to as C module), load switch without grounding assembly (referred to as CB module), circuit breaker with grounding assembly (referred to as V module), and circuit breaker without grounding assembly (VB module for short), circuit breaker contact switch (VZ module for short), load switch + fuse combined electrical switch assembly (F module for short) and isolation switch and assembly (G module for short).

Use environment

  • Ambient temperature: air temperature +55℃, temperature -30℃;

  • Altitude: ≤2000mm

  • Ambient humidity: the average value of Sundi is not more than 95%, and the monthly relative average value is not more than 90%;

  • Earthquake intensity: no more than 8;

  • There is no fire, explosion, serious pollution, chemical corrosion and severe vibration.

Executive standard

  • IEC 62271-1-2011 High-voltage switchgear and control equipment.

  • IEC 62271-200-2011 High Voltage Switchgear and Control Equipment Part 200: Metal-enclosed AC switchgear and control equipment for rated voltages above 1kV and below 52k (including 52kV).

  • GB 1984-2003 High Voltage AC Circuit Breaker.

  • GB 1985-2004 High voltage AC isolation start and grounding switch.

  • GB 3804-2004 3.6kV~40.5kV high voltage AC load switch.

  • GB 16926-2009 AC load switch-fuse combination electrical appliance.

  • GB/T 11022-2011 Common technical requirements for high-voltage switchgear and control equipment standards.

  • DL/T 403-2000 12kV-40.5kV high voltage vacuum circuit breaker ordering technical conditions.

  • Q/GDW 730-2012 12kV solid insulation ring network cabinet technical conditions.

  • 1016006-0010-AO 12kV solid insulated ring network cabinet general technical specifications.

Application advantages of ring main unit

  • Application in environmental protection areas: The product is a solid insulation vacuum arc extinguishing technology, does not contain SF6 greenhouse gas, and will not produce harmful gases after operation.

  • Application in high-temperature areas: SF6 gas is not used, and there is no need to consider the influence of air box pressure during high-temperature operation.

  • Application in low temperature areas: SF6 gas is not used, and there is no need to consider the problem of liquefaction of SF6 gas at low temperature.

  • Application in plateau areas: SF6 gas is not used, and there is no need to consider the influence of the pressure difference between the inside and outside of the gas box on the deformation of the gas box.

  • Application in explosion-proof places: The product adopts vacuum interrupter for arc extinguishing. The vacuum interrupter is a negative pressure product, which is poured into the solid medium at the same time, which strengthens its explosion-proof performance and is suitable for applications in explosion-proof places.

  • Application in basement: The relative density of SF6 gas is 5 times that of air in the same state. The leaked SF6 gas and its decomposition products are not easy to diffuse, and will accumulate in low-lying areas, which can easily cause injury and suffocation to maintenance personnel.

  • Application in frequent operation places: the mechanical life of the solid insulation main switch exceeds 10,000 times.

  • Application in dirty places: The product adopts solid insulation technology, the protection level of the switch body is IP67, and the fully insulated and sealed structure has no exposed live parts.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.