6.9kV 7.2kV 12kV 24kV Solid Insulated Metal-enclosed ring main unit/distribution board

  • 6.9kV 7.2kV 12kV 24kV Solid Insulated Metal-enclosed ring main unit/distribution board

Key attributes

Brand ROCKWILL
Model NO. 6.9kV 7.2kV 12kV 24kV Solid Insulated Metal-enclosed ring main unit/distribution board
Rated voltage 12kV
Rated frequency 50/60Hz
Series CKSS

Product descriptions from the supplier

Description
Description

Pioneer in China's eco-friendly switchgear sector, we have specialized in R&D and manufacturing of SF₆-free switchgear for decades. With core technologies, we have established industry standards. Boasting a fully independent end-to-end production chain, we have built a product matrix of zero-emission and high-reliability eco-friendly switchgear, making us a trusted choice for power grid construction.

The ring main unit is insulated metal common tank enclosed switchgear, consisting of load break switch unit, load break switch fuse combination electrical unit, vacuum circuit breaker unit, and the incoming line unit of bus. It adopts a range of advanced technologies and materials, with excellent electrical and mechanical properties, less affected by environment and climate, in small size, easy to install, easy to operate, with no need of maintenance, and can be flexibly combined. Its clear and intuitive design ensures simple and direct operation, the feeder's connection capacity is large, suitable for a variety of wiring systems.

Feature

  • Excellent solid insulation performance: Adopts advanced solid insulating materials such as epoxy resin to fully encapsulate internal high-voltage live components, featuring high insulation strength that can effectively withstand electrical stress at 12kV or 24kV voltage levels. Unlike traditional insulation methods, it is not affected by environmental factors such as humidity, dust, and pollution, greatly reducing the risk of flashover and breakdown, and ensuring long-term stable operation of the equipment in complex environments.

  • Compact and space-efficient design: The metal-enclosed structure is extremely compact with a small footprint, suitable for installation in space-constrained locations such as urban distribution stations, commercial building switchrooms, and industrial park substations. By optimizing the internal layout, various functional modules are closely integrated, reducing installation space requirements while facilitating transportation and on-site installation and commissioning, thus improving the utilization efficiency of the site space.

  • Multiple safety protection mechanisms: The cabinet body adopts a fully enclosed metal shell, which can effectively shield the internal high-voltage electric field and prevent accidental electric shock to personnel. It is equipped with complete internal mechanical and electrical interlocking devices to strictly prevent dangerous situations such as incorrect switching operations, on-load switching, and entry into live compartments. Some products are also equipped with live display devices to intuitively show the live status of the equipment in real-time, further ensuring the safety of operators and equipment.

  • Low maintenance and long service life: The solid insulating materials have strong stability, and internal components are sealed in the metal shell, effectively isolating external erosion, reducing component aging and failures caused by environmental factors, and achieving long-term maintenance-free operation. Under normal circumstances, the service life of the equipment can reach 20 years or more, reducing the life-cycle maintenance costs and equipment replacement frequency, and providing users with reliable long-term investment returns.

  • Flexible power distribution adaptability: Supports multiple wiring methods such as ring network power supply and radial power supply, and can be easily connected with 12kV or 24kV transformers, cables, and other power equipment, flexibly adapting to different medium-voltage distribution network topologies. It can easily meet the needs of various power distribution scenarios, whether for urban power grid upgrading projects or complex power supply requirements in industrial plants.

  • Outstanding environmental performance: Different from SF6 gas-insulated ring main units, this equipment does not use SF6 gas, avoiding potential environmental hazards caused by SF6 gas leakage, and conforming to the current concept of green environmental protection. It is especially suitable for the construction of power distribution facilities in areas with strict environmental requirements, such as ecological protection zones and urban core areas.


Unit code

Meaning

C

Standard single casing load break switch unit

F

Load break switch and fuse combination

V

Apparatus unit

D

Cable unit(without switch)

+

Side casing of busbar

-

Top casing of busbar

SL

Bus couple unit

M

Metering unit

PT

PT unit

1K2(4)

Double-sleeve outgoing load break switch unit

Technical Sheet

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

ltem

Unit

Load break switch unit

Combination apparatus

Fuse unit

Rated voltage

kV

12/24

12/24

12/24

Rated frequency

Hz

50

50

50

Rated current

A

630

Depend on rated current of fuse

630

P.F.withstand voltage (phase to phase.phase to earth)

kV

42/65

42/65

42/65

Ated insulation levels

P.F.withstand voltage(Across open contacts)

48/79

48/79

48/79

P.F.withstand voltage (Control and auxiliary circuit)

2/2

2/2

2/2

Lightning impulse withstand voltage (phase to phase, phase to earth)

75/125

75/125

75/125

Across open contacts

85/145

85/145

85/145

Ogauge pressure test

-

Pass

Pass

Pass

Rated short time withstand current

kA

20/4s/20/3s

-

20/4s/20/4s

Rated peak withstand current

kA

63

-

63

Rated short circuit making current

kA

50 or 63

Subject to high-voltage fuse

50

Rated short circuit breaking current

kA

-

Subject to high-voltage fuse

20/20

Rated transform current

A

-

1750/1400

-

Rated active load breaking current

A

630

-

-

Rated Closed loop breaking current

A

630

-

630

Mechanical life

Load break switch/breaker

Time

5000

5000

10000

Isolating switch/earthing switch

5000

5000

5000

Loop resistance

μΩ

≤120

-

≤120

Inflation pressure

Rated inflation pressure(absolute pressure)

bar

1.3

1.3

1.3

Minimum inflation pressure(absolute pressure)

1.2

1.2

1.2

Relative rate leakage of gas

%

≤0.02

≤0.02

≤0.02

Remark: l :Neutral point earthing system through low resistance

FAQ
Q: What is the service life of environmentally friendly cabinets?
A:
The design service life of environmentally friendly cabinets is 20-25 years, which is the same as that of traditional SF6 cabinets. The actual service life depends on the operating environment, maintenance quality, and component quality. Regular maintenance (e.g., replacing seals, cleaning components) can effectively extend the service life. Most manufacturers provide 10-15 years of quality assurance for key components (e.g., vacuum interrupters, insulating cabinets).
Q: How to handle the aging parts of environmentally friendly cabinets?
A:
For aging parts (e.g., seals, relays, meters), replace them with original accessories provided by the manufacturer to ensure compatibility and performance. For core components (e.g., vacuum interrupters, insulating cabinets) that are severely aged or damaged, contact the manufacturer for professional replacement or renovation. Waste parts should be disposed of in accordance with environmental protection regulations; recyclable components (e.g., steel cabinets, copper conductors) should be recycled to reduce environmental impact.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.