What are the key differences between oil-filled and dry-type power transformers in high-voltage applications ?

Encyclopedia
Field: Encyclopedia
0
China

Insulating medium

  • Oil - filled type: It uses insulating oil (such as mineral oil, silicone oil) as the main insulating medium. The iron core and coils are immersed in the oil. The insulating property of the oil is utilized to isolate conductors with different potentials, preventing short - circuits and discharges.

  • Dry - type: It adopts air or solid insulating materials, such as epoxy resin, as the insulating medium. Materials like epoxy resin are wrapped around the coils, serving as insulation and mechanical protection.

Cooling method

  • Oil - filled type: It mainly relies on the circulation of insulating oil for heat dissipation. When the transformer is operating, the generated heat is transferred to the insulating oil. The oil dissipates the heat to the external environment through natural convection or with the help of cooling equipment (such as radiators, cooling fans, etc.).

  • Dry - type: It usually uses natural ventilation or forced air - cooling for heat dissipation. In the case of natural ventilation, heat is carried away by the natural convection of air; for forced air - cooling, fans are installed to accelerate the air flow and improve the heat - dissipation efficiency.

Structural design

  • Oil - filled type: It has a sealed oil tank to accommodate the insulating oil, iron core, coils and other components. There are usually auxiliary devices such as radiators, conservators, and gas relays outside to ensure the normal operation of the insulating oil and protect the transformer.

  • Dry - type: The structure is relatively simple. Generally, there is no oil tank and complex oil - circulation system. The iron core and coils are directly exposed to the air or encapsulated by solid insulating materials like epoxy resin. The iron core and coils can be directly seen from the appearance.

Voltage and capacity ratings

  • Oil - filled type: It can meet the requirements of various voltage levels and large capacities. From low - voltage to extra - high - voltage (500kV and above), the capacity can range from several hundred kVA to several hundred MVA. It is widely used in high - voltage and large - capacity power transmission and distribution.

  • Dry - type: Generally, it is suitable for medium - low voltage levels (10kV - 35kV) and medium - small capacities (usually less than 30MVA). In higher - voltage and larger - capacity scenarios, its application is limited due to heat - dissipation and insulation problems.

Maintenance requirements

  • Oil - filled type: Maintenance work is more complex and frequent. It is necessary to regularly check the quality of the insulating oil, including the electrical characteristics of the oil, moisture content, impurity content, etc., and filter or replace the oil if necessary. It is also necessary to monitor the oil level and check the cooling system.

  • Dry - type: Maintenance is relatively simple. It mainly involves regularly cleaning the outside of the transformer and the ventilation equipment, checking whether the insulating materials have cracks, aging, etc., and conducting insulation resistance tests.

Safety and environmental friendliness

  • Oil - filled type: There are risks of insulating oil leakage and fire. If the insulating oil is not properly disposed of, it may pollute the environment, and the oil may contain harmful substances.

  • Dry - type: Since it does not use insulating oil, there is no risk of oil leakage and no oil - related fire. It has advantages in fire - prevention and explosion - prevention, and is more environmentally friendly.

 Cost

  • Oil - filled type: The manufacturing cost is mainly concentrated on the insulating oil, metal shell and vacuum treatment process. The initial cost is relatively higher than that of dry - type transformers, but it has a high cost - performance ratio in high - power and high - voltage applications.

  • Dry - type: Due to the absence of insulating oil, the material cost is relatively low. However, the use of epoxy resin and high - efficiency cooling systems will increase the cost, especially in large - capacity application scenarios.

Application scenarios

  • Oil - filled type: It is mostly used outdoors, in large industrial enterprises, substations and transmission lines, and is suitable for high - voltage and long - distance power transmission scenarios.

  • Dry - type: It is widely used in places that require high safety and low noise, such as office buildings, shopping malls, hospitals, etc., and is also suitable for areas with high environmental requirements.

Give a tip and encourage the author!

Recommended

Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
01/29/2026
What’s the Difference Between Rectifier Transformers and Power Transformers?
What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
01/29/2026
How to Judge, Detect and Troubleshoot Transformer Core Faults
1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
01/27/2026
A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
01/27/2026
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.