What is the difference between wound rotor induction machine and self-excited induction machine?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Differences Between Wound Rotor Induction Motors and Squirrel Cage Induction Motors

Wound Rotor Induction Motors (WRIM) and Squirrel Cage Induction Motors (SCIM) are two common types of induction motors that differ in structure, performance, and application. Below are the key distinctions between them:

1. Rotor Construction

Wound Rotor Induction Motor (WRIM):

  • The rotor consists of three-phase windings connected to external circuits via slip rings and brushes. This allows the rotor windings to be connected to external resistors or other control devices.

  • The ability to externally regulate the rotor windings provides more flexible control, especially for starting and speed regulation.

Squirrel Cage Induction Motor (SCIM):

  • The rotor is made of cast aluminum or copper bars arranged in a cage-like structure, hence the name "squirrel cage motor."

  • This design is simple and robust, with no slip rings or brushes, resulting in lower maintenance costs. However, it does not allow for direct external regulation of the rotor current.

2. Starting Characteristics

Wound Rotor Induction Motor (WRIM):

During startup, resistors can be inserted in series with the rotor windings to reduce the starting current and increase the starting torque. As the motor accelerates, the resistors are gradually reduced and eventually short-circuited.

This method allows for a smoother startup process, making it suitable for applications requiring high starting torque, such as cranes, conveyors, and large pumps.

Squirrel Cage Induction Motor (SCIM):

At startup, the rotor current is high, leading to a significant starting current, typically 6-8 times the rated current. The starting torque is relatively low, around 1.5-2 times the rated torque.

To reduce the starting current, star-delta starters or soft starters are often used, but the starting performance is still not as good as that of wound rotor motors.

3. Speed Control

Wound Rotor Induction Motor (WRIM):

The rotor windings can be regulated through external circuits, allowing for a wide range of speed control. Common speed control methods include rotor resistance control and cascade control.

While this method is less precise than variable frequency drive (VFD) control, it is effective for applications requiring substantial speed variation.

Squirrel Cage Induction Motor (SCIM):

Traditional squirrel cage motors do not have built-in speed control capabilities, as their speed is primarily determined by the supply frequency. To achieve speed control, a VFD is typically required to vary the supply frequency.

VFD control enables precise, stepless speed adjustment but increases system complexity and cost.

4. Efficiency and Maintenance

Wound Rotor Induction Motor (WRIM):

The presence of slip rings and brushes requires higher maintenance, including regular inspection and replacement of brushes. Friction from the slip rings and brushes also leads to some energy loss, affecting motor efficiency.

However, for applications requiring frequent starting, braking, or speed regulation, the performance advantages of wound rotor motors may outweigh the maintenance costs.

Squirrel Cage Induction Motor (SCIM):

Without slip rings or brushes, the design is simple, requiring minimal maintenance and offering reliable long-term operation.

Efficiency is generally higher, especially under full load conditions, as there are no additional mechanical friction losses.

5. Application Areas

Wound Rotor Induction Motor (WRIM):

Suitable for applications requiring high starting torque, frequent starting/stopping, and speed control, such as:

  • Cranes

  • Conveyors

  • Fans

  • Pumps

  • Rolling mills in the metallurgical industry

Squirrel Cage Induction Motor (SCIM):

Widely used in standard industrial applications where speed control or high starting torque is not critical, such as:

  • Air conditioning systems

  • Ventilation equipment

  • Water pumps

  • Conveyor belts

  • Agricultural machinery

6. Cost

Wound Rotor Induction Motor (WRIM):

Due to its more complex structure, the manufacturing cost is higher, especially with the need for additional components like slip rings, brushes, and control systems.

It is suitable for high-performance applications, where the initial investment may be higher, but the performance benefits can lead to increased productivity over time.

Squirrel Cage Induction Motor (SCIM):

The simple design results in lower manufacturing costs, making it widely used in various general-purpose industrial equipment.

Ideal for cost-sensitive applications, especially those that do not require complex control or speed regulation features.

Summary

Wound rotor induction motors and squirrel cage induction motors each have their own advantages and disadvantages. The choice between the two depends on the specific application requirements. Wound rotor motors offer superior starting performance and speed regulation, making them suitable for applications requiring high starting torque and frequent speed changes. On the other hand, squirrel cage motors excel in simplicity, low maintenance, and cost-effectiveness, making them widely used in standard industrial equipment.

Give a tip and encourage the author!
Recommended
How to Choose a Thermal Relay for Motor Protection?
How to Choose a Thermal Relay for Motor Protection?
Thermal Relays for Motor Overload Protection: Principles, Selection, and ApplicationIn motor control systems, fuses are primarily used for short-circuit protection. However, they cannot protect against overheating caused by prolonged overloading, frequent forward-reverse operation, or undervoltage operation. Currently, thermal relays are widely used for motor overload protection. A thermal relay is a protective device that operates based on the thermal effect of electric current, and is essentia
James
10/22/2025
How to Choose & Maintain Electric Motors: 6 Key Steps
How to Choose & Maintain Electric Motors: 6 Key Steps
"Selecting a High-Quality Motor" – Remember the Six Key Steps Inspect (Look): Check the motor’s appearanceThe motor’s surface should have a smooth, even paint finish. The nameplate must be properly installed with complete and clear markings, including: model number, serial number, rated power, rated current, rated voltage, allowable temperature rise, connection method, speed, noise level, frequency, protection rating, weight, standard code, duty type, insulation class, manufacturing date, and ma
Felix Spark
10/21/2025
 What Is the Working Principle of a Power Plant Boiler?
What Is the Working Principle of a Power Plant Boiler?
The working principle of a power plant boiler is to utilize the thermal energy released from fuel combustion to heat feedwater, producing a sufficient quantity of superheated steam that meets specified parameters and quality requirements. The amount of steam produced is known as the boiler's evaporation capacity, typically measured in tons per hour (t/h). Steam parameters primarily refer to pressure and temperature, expressed in megapascals (MPa) and degrees Celsius (°C), respectively. Steam qua
Edwiin
10/10/2025
What is the principle of live-line washing for substations?
What is the principle of live-line washing for substations?
Why Do Electrical Equipment Need a "Bath"?Due to atmospheric pollution, contaminants accumulate on insulating porcelain insulators and posts. During rain, this can lead to pollution flashover, which in severe cases may cause insulation breakdown, resulting in short circuits or grounding faults. Therefore, the insulating parts of substation equipment must be periodically washed with water to prevent flashover and avoid insulation degradation that could lead to equipment failure.Which Equipment Is
Encyclopedia
10/10/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.