Key attributes

Brand ROCKWILL
Series RDS
Rated voltage 40.5kV/72.5kV/126kV
Rated current 2500A /2000A
Rated short-time withstand current 40kA
Rated frequency 50/60Hz
Description
The RDS series outdoor high-voltage disconnector is designed for three-phase AC power systems at 40.5 kV, 72.5 kV, and 126 kV. It is used for no-load line switching, isolation of high-voltage equipment, and bus-transfer current switching, providing visible isolating gaps for safe maintenance.

The disconnector adopts a V-arrangement double-post center-break design. Two rotating post insulators are mounted on a common base at a 50° angle. The contact finger arm and contact head arm are fixed to the top of each insulator. The operating mechanism drives one insulator to rotate, which drives the other insulator in reverse through an angular gear or linkage, achieving opening and closing with a horizontal isolating gap.

The product is available with an earthing switch on one or both sides, and can be operated via manual operating mechanisms with three-pole linkage. A direct mechanical interlock between the main disconnector and earthing switch shafts ensures reliable interlocking without a complex gearbox.

Key Features

  • V-arrangement center-break design :Two post insulators arranged in a V-configuration with 90° or 180° drive for reliable opening and closing; horizontal isolating gap provides visible break for safe maintenance
  • Self-contained contact :Special copper alloy contact uses its own elastic force for tight connection, eliminating contact springs and the associated risk of spring corrosion, shunting, heating, and contact resistance increase
  • Aluminum alloy conductive arm :Rectangular aluminum alloy pipe construction; high strength, light weight, large radiation area, and strong corrosion resistance
  • Maintenance-free rotating base :Sealed closure design prevents ingress of moisture, dust, and harmful gases; low-temperature lubricant in bearings does not leak or harden; thrust and radial ball bearings share gravity and horizontal load components, maintaining stable operating torque over the equipment lifetime
  • Direct mechanical interlock :Interlock between main disconnector and earthing switch is mounted directly on the main shaft and earthing switch shaft, eliminating the need for a separate gearbox; reliable interlock with easy on-site adjustment
  • Flexible configuration :Available with or without earthing switch (left, right, or both sides); optional manual operating mechanisms with three-pole linkage
  • Sequential control ready :Supports one-key sequential control with double-confirmation function for remote operation

Technical Parameters

Item Unit 40.5 kV 72.5 kV 126 kV
Rated voltage (Um) kV 40.5 72.5 126
Rated frequency Hz 50 / 60 50 / 60 50 / 60
Rated current A 2500 2000 2000
Rated short-time withstand current (rms) kA 40 40 40
Rated short-circuit withstand duration s 3 3 3
Rated peak withstand current kA peak 100 100 100
Rated power-frequency withstand voltage (1 min), phase to earth kV 95 140 230
Rated power-frequency withstand voltage (1 min), across isolating distance kV 95 + 23 140 + 42 230 + 73
Rated lightning impulse withstand voltage, phase to earth kV peak 200 325 550
Rated lightning impulse withstand voltage, across isolating distance kV peak 200 + 35 325 + 59 550 + 103
Mechanical endurance operations 10,000 10,000 5,000
Bus-transfer current switching A 1600 1600 1600
Bus-transfer voltage V 100 100 100
Terminal static load (longitudinal / horizontal / vertical) N 750 / 500 / 750 750 / 500 / 750 1,000 / 750 / 1,000
Operating altitude m ≤ 2,000 ≤ 2,000 ≤ 2,000
Pollution level per IEC 60815 class IV (very heavy) IV (very heavy) IV (very heavy)
Radio interference level µV ≤ 500 ≤ 500 ≤ 500

 Earthing Switch Induced Current Switching Capability 

Item Value
Electromagnetic induction current 50 A
Electromagnetic induction voltage 0.5 kV
Electrostatic induction current 0.4 A
Electrostatic induction voltage 3 kV

  Application Scenarios

  • Transmission and distribution substations:Isolation of high-voltage equipment and busbars for safe maintenance at 40.5 kV, 72.5 kV, and 126 kV voltage levels
  • Industrial power systems:Disconnecting and isolating overhead lines and equipment in heavy industrial environments
  • Grid interconnections:Bus-transfer current switching at distribution substations and switching stations
  • Overhead line termination : Visible isolation at line entrances to substations and switching stations
  • Heavy pollution areas :Suitable for class IV pollution environments with high creepage distance requirements

Order Information

When ordering, the following parameters must be specified:

  • Product model and voltage rating
  • Rated current and rated short-time withstand current
  • Creepage distance requirement
  • Earthing switch configuration (none, left, right, or both sides)
  • Operating mechanism type and auxiliary switch voltage and contact configuration
  • Installation method (horizontal, 25° inclination, or side installation)
  • Electromagnetic lock power supply type and voltage (if applicable)

Solutions - High voltage disconnect switch

Documentation Resource Library High voltage disconnect switch

Restricted
12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals 12 to 800kV Center Vee Center Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Restricted
252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals 252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Public.
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

The RDS‑series outdoor high‑voltage disconnector adopts a V‑arrangement double‑post center‑break design. Two rotating post insulators are installed on one common base at 50° angle; the operating mechanism drives one insulator, and angular gears or linkages drive the other insulator to reverse‑rotate, forming a horizontal visible isolating gap for opening and closing operations.

The RDS‑series outdoor high‑voltage disconnector is equipped with self‑contained special copper‑alloy contacts. It relies on the inherent elastic force of the contact itself to achieve tight connection, removing contact springs.

This avoids common risks such as spring corrosion, shunting, overheating and rising contact resistance caused by spring failure.

The rotating base of the RDS‑series outdoor high‑voltage disconnector uses fully sealed construction to block moisture, dust and harmful gas ingress.

Its bearing is filled with non‑leaking, non‑hardening low‑temperature lubricant. Thrust and radial ball bearings jointly bear gravity and horizontal loads, keeping stable operating torque throughout the whole service life with little routine maintenance.

Yes, the RDS‑series outdoor high‑voltage disconnector can be deployed in Class IV heavy‑pollution areas with high creepage‑distance requirements.

It is widely used in transmission‑distribution substations, industrial power systems, grid interconnection stations and overhead‑line termination occasions under harsh environmental conditions.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register