HV disconnect switch China manufacturer for AIS Substations-252kV 363kV

Add us on Google
  • HV disconnect switch China manufacturer for AIS Substations-252kV 363kV

Key attributes

Brand ROCKWILL
Series RDS
Rated voltage 252kV/363kV
Rated current 2000-5000A
Rated short-time withstand current 50/63kA
Rated frequency 50/60Hz
Description
The RDS series outdoor high-voltage disconnector is designed for 252 kV and 363 kV three-phase AC power systems. It is used for no-load line switching, equipment isolation, and bus-transfer current switching, providing a visible isolating gap for safe maintenance.

The disconnector adopts a horizontal center-break structure with two insulator columns per phase. The conductive blade is mounted on the rotating insulator and opens at the center, forming a horizontal isolating break. The design features low operating torque and minimized contact resistance.

The earthing switches can be installed on one or both sides. For 252 kV, the disconnector is motor-operated with three-pole linkage. For 363 kV, the disconnector uses single-pole motor operation with three-pole linkage capability. The earthing switch is manually operated for both voltage levels.

Key Features

  • Horizontal center-break design:Two insulator columns per phase with center-opening blade, providing a clear visible isolating gap with low operating torque and stable contact performance
  • Reliable current path:Self-cleaning contact system with multiple-finger tulip contacts ensures stable current transfer and high short-circuit withstand capability
  • Versatile earthing switch:The earthing switch installable on one or both sides, manually operated for reliable earthing
  • Proven operating mechanism:Motor mechanism with three-pole linkage for 252 kV; single-pole motor operation with three-pole linkage capability for 363 kV
  • Low contact resistance:Silver-plated contacts and optimized conductive path minimize resistive losses and temperature rise
  • Factory assembled:Complete assembly and adjustment completed before delivery, reducing on-site installation and commissioning work

Technical Parameters

Item Unit 252 kV 363 kV
Rated voltage (Um) kV 252 363
Rated frequency Hz 50 / 60 50 / 60
Rated current A 2,000, 3,150, 4,000 4,000, 5,000
Rated short-time withstand current kA 50 / 63 63
Rated short-circuit withstand duration s 3 3
Rated peak withstand current kA peak 125 / 160 160
Rated power-frequency withstand voltage (1 min), phase to earth kV 460 510
Rated power-frequency withstand voltage (1 min), across isolating distance kV 460 + 145 510 + 210
Rated lightning impulse withstand voltage, phase to earth kV peak 1,050 1,175
Rated lightning impulse withstand voltage, across isolating distance kV peak 1,050 + 200 1,175 + 295
Mechanical endurance operations 10,000 10,000
Terminal static load (longitudinal / transverse / vertical) N 2,500 / 1,500 / 1,250 4,000 / 1,600 / 1,500
Bus-transfer current switching capability A / V 1,600 / 100 2,400 / 435
Creepage distance mm 6,300 / 7,812 9,450
Operating altitude m ≤ 2,000 ≤ 2,000
Pollution level per IEC 60815 class IV (very heavy) IV (very heavy)
Radio interference voltage (RIV) µV ≤ 500 ≤ 500

 Operating Mechanism

Item 252 kV 363 kV
Disconnector mechanism Motor (three-pole linkage) Motor (single-pole, three-pole linkage supported)
Earthing switch mechanism Manual Manual
Motor voltage AC 380 V / DC 220 V AC 380 V / DC 220 V
Control voltage AC 220 V / DC 220 V / DC 110 V AC 220 V / DC 220 V / DC 110 V
Opening / closing time 12 s ± 1 s 16 s ± 1 s

 Application Scenarios

  • Transmission substations:Isolation of busbars, circuit breakers, and overhead lines at 252 kV and 363 kV
  • Grid interconnections:Bus-transfer current switching at transmission switching stations
  • Heavy pollution areas:Creepage distance up to 9,450 mm suitable for Class IV (very heavy) pollution environments
  • High-altitude installations:Standard design for altitudes up to 2,000 m; customized solutions available for higher altitudes

Order Information

When ordering, specify:

  • Product model and rated voltage
  • Rated current and rated short-time withstand current
  • Creepage distance requirement
  • Earthing switch configuration (none, left, right, or both sides)
  • Arrangement form (cross or parallel)
  • Upper busbar type (soft or hard) and tubular busbar outer diameter
  • Operating mechanism (manual or motor), motor voltage, and control voltage
  • Number of auxiliary switch contacts
  • Installation method
  • Altitude and pollution level (if different from standard)

Solutions - High voltage disconnect switch

Case Studies - High voltage disconnect switch

Related Blogs - High voltage disconnect switch

Documentation Resource Library High voltage disconnect switch

12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Restricted
12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals 12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals
Restricted
252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals 252 to 1100kV Double End Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English
Rockwill Ecosystem Profile
Public
Rockwill Ecosystem Profile Rockwill Ecosystem Profile
Profile
English
RHB-330kV Live tank SF6 gas circuit breaker
Restricted
RHB-330kV Live tank SF6 gas circuit breaker RHB-330kV Live tank SF6 gas circuit breaker
Drawings
English
PDF
Intelligent isolation switch catalog
Public
Intelligent isolation switch catalog Intelligent isolation switch catalog
Brochure
English
ZFW34A-252kV- GIS-Catalog
Restricted
ZFW34A-252kV- GIS-Catalog ZFW34A-252kV- GIS-Catalog
Catalogue
English
PDF
Outdoor live tank SF6 circuit breaker
Restricted
Outdoor live tank SF6 circuit breaker Outdoor live tank SF6 circuit breaker
Catalogue
English
PDF

Certifcations High voltage disconnect switch

  • ISO9001 quality management system certificate

Frequently asked questions

The RDS‑series outdoor high‑voltage disconnector adopts a horizontal center‑break structure. Each phase is equipped with two insulator columns; the conductive blade is mounted on rotating insulators and splits open at the centre, forming a horizontal isolating break. This design realizes low operating torque and low contact resistance.

For the RDS‑series outdoor high‑voltage disconnector, the 252 kV model adopts motor‑driven three‑pole linkage operation. The 363 kV model adopts single‑pole motor operation and supports three‑pole linkage function. The earthing switches for both voltage classes are manually operated.

The RDS‑series outdoor high‑voltage disconnector is fitted with a self‑cleaning multi‑finger tulip‑type contact system.

Together with silver‑plated contacts and optimized conductive paths, it delivers stable current transmission, high short‑circuit withstand capacity, low contact resistance, and effectively reduces power loss and temperature rise.

Yes. Major assembly and fine adjustment work are finished in our factory before delivery. It greatly cuts on-site installation and commissioning time, lowers the requirement for site construction teams, and helps your project meet the scheduled energization timeline.

We can provide customized solutions for high-altitude applications beyond the standard scope. We will adjust insulation configuration and creepage distance according to your site altitude and pollution conditions, to guarantee stable operation under high-altitude low-atmosphere pressure environment.

It supports cross arrangement and parallel arrangement on site. It matches different AIS substation layout schemes, and we can optimize the structure design according to your busbar type and busbar size to fit the overall substation layout.

Horizontal center-break structure creates a clear and visible isolation gap. It features smooth action and low operating torque. The structure is widely adopted in conventional AIS substations, with mature operation experience and convenient inspection and maintenance for operators.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear

Comments

Share your question or perspective
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register