High voltage telescopic disconnect switch 550kV

  • High voltage telescopic disconnect switch 550kV

Key attributes

Brand ROCKWILL
Series RDS
Rated voltage 550kV
Rated current 3150-5000A
Rated short-time withstand current 63kA
Rated frequency 50 / 60Hz
Description
The Rockwill RDS series outdoor high voltage disconnector is rated for 550 kV, designed for three-phase AC transmission systems. It provides visible isolation for equipment maintenance, performs no-load line switching, and handles bus-transfer current switching in EHV substations. The disconnector is suitable for 500 kV and 550 kV nominal system voltages.

The disconnector adopts a double-column horizontal telescopic structure, consisting of base frame, insulator columns, conductive blade assembly, and operating mechanism. The telescopic contact system forms a reliable insulating break when opened, providing a clearly visible air gap for safe maintenance isolation.

The SRCJ2 motor actuator provides single-pole operation with three-pole linkage capability. The  earthing switch can be installed on one or both sides and is available with manual or motor operation.

Key Features

  • Robust telescopic structure:Double-column horizontal telescopic design provides a clearly visible isolating gap when open, with reliable plug-type contacts ensuring positive engagement
  • EHV-grade insulation performance:Designed for 550 kV class insulation coordination, with power-frequency, lightning impulse, and switching impulse withstand levels meeting stringent EHV substation requirements
  • Reliable earthing switch :the earthing switch with two-step opening and closing motion ensures reliable contact under heavy short-circuit conditions; available on one or both sides
  • Flexible operation:Motor actuator supports single-pole operation with three-pole linkage capability, enabling both independent phase control and synchronized three-phase switching
  • High mechanical endurance:Robust mechanical design rated for extended operating cycles, suitable for frequent switching in transmission substations
  • Large creepage distance options :Standard and heavy-duty creepage distances available for clean and polluted environments
  • Low radio interference:Optimized contact design and smooth surface profiles control corona discharge, maintaining low radio interference voltage levels
  • IEC 62271-102 compliant :Fully type-tested in accordance with IEC 62271-102 for disconnectors and earthing switches

Technical Parameters

Item Unit 550 kV
Rated voltage (Um) kV 550
Rated frequency Hz 50 / 60
Rated current A 3,150, 4,000,5000
Rated short-time withstand current kA 63
Rated short-circuit withstand duration s 3
Rated peak withstand current kA peak 160
Rated power-frequency withstand voltage (1 min), phase to earth kV 620
Rated power-frequency withstand voltage (1 min), across isolating distance kV 620 + 315
Rated lightning impulse withstand voltage, phase to earth kV peak 1,550
Rated lightning impulse withstand voltage, across isolating distance kV peak 1,550 + 445
Rated switching impulse withstand voltage, phase to earth kV peak 1,175
Rated switching impulse withstand voltage, across isolating distance kV peak 1,175 + 315
Mechanical endurance operations 10,000
Terminal static load (longitudinal / transverse / vertical) N 5,000 / 2,500 / 2,000
Bus-transfer current switching capability A / V 2,400 / 435
Creepage distance mm 13,750 / 17,050
Operating altitude m ≤ 2,000
Pollution level per IEC 60815 class IV (very heavy)
Radio interference voltage (RIV) µV ≤ 500

 Operating Mechanism

Item 550 kV
Disconnector actuator SRCJ2 motor (single-pole, three-pole linkage supported)
Earthing switch actuator Manual or motor operated
Motor voltage AC 380 V / DC 220 V
Control voltage AC 220 V / DC 220 V / DC 110 V
Opening / closing time 18 s ± 1 s

 Application Scenarios

  • 550 kV EHV transmission substations:Busbar, line, and circuit breaker isolation in 500 kV and 550 kV class transmission grids
  • Busbar disconnector applications:Telescopic structure allows direct installation under the busbar, occupying minimal space in the substation layout
  • EHV substation brownfield expansion:Single-pole operation allows phased outage during substation extension without full bay shutdown
  • Industrial EHV take-off stations:Isolation for large industrial loads connected directly to 550 kV transmission networks

When ordering, specify:

  • Product model (RDS-550) and rated current
  • Creepage distance requirement (standard or heavy-duty)
  • Earthing switch configuration (none, left, right, or both sides)
  • Earthing switch operation (manual or motor)
  • Arrangement form (right-angle or parallel)
  • Upper busbar type (tubular or strain) and terminal connector type
  • Motor voltage and control voltage
  • Number of auxiliary switch contacts
  • Altitude and pollution level (if different from standard)

Documentation Resource Library disconnect switch

Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register