High voltage disconnect switch suppliers 252kV

  •  High voltage disconnect switch suppliers 252kV

Key attributes

Brand ROCKWILL
Series RDS
Rated voltage 252kV
Rated short-time withstand current 50/63kA
Rated current 2000-4000A
Rated frequency 50 / 60Hz
Description
 

The RDS series outdoor disconnector is rated for 252 kV and is designed for three-phase AC transmission systems with nominal voltages of 220 kV, 230 kV, 245 kV, and 252 kV. It provides visible isolation for equipment maintenance and performs no-load line switching and bus-transfer current switching.

The disconnector uses a two-column horizontal center-break structure. The conductive blade is driven by the rotating insulator post and opens at the center, forming a clear visible isolating gap. The main circuit resistance is minimized through silver-plated contacts and an optimized current path.

The disconnector is operated by a motor mechanism with three-pole linkage. The earthing switch is installed on one or both sides as required and is manually operated with three-pole synchronization.

Key Features

  • Single-voltage optimized design:Engineered specifically for the 252 kV class, with insulation coordination and mechanical ratings sized precisely for 220 kV through 252 kV nominal networks, eliminating over-engineering found in multi-voltage platform designs
  • Global voltage compatibility:One product design covers multiple nominal system voltages including 220 kV (Europe, Asia, South America), 230 kV (North America), 245 kV (IEC standard), and 252 kV (China, Middle East), reducing qualification and inventory complexity for EPC contractors and utilities operating across multiple regions
  • Center-break mechanism with reduced operating torque:Rotating insulator drive system with sealed bearings and self-lubricating joints minimizes the operating force required, allowing a compact motor mechanism and reducing mechanical stress on the supporting structure
  • Silver-plated multi-point contact system:Main contacts are silver-plated with multiple parallel current paths, keeping contact resistance stable below 120 µΩ throughout the 10,000-operation mechanical life without intermediate maintenance
  • Flexible earthing switch arrangement :The earthing switch can be installed on the left, right, or both sides of each phase, with independent manual operation per phase or synchronized three-pole linkage via connecting rods, adapting to different substation earthing schemes
  • Compact phase spacing:Optimized phase-to-phase distance reduces switchyard width for 252 kV substations, making it suitable for brownfield expansions where existing bay spacing is constrained

Technical Parameters

Item Unit 252 kV
Rated voltage (Um) kV 252
Rated frequency Hz 50 / 60
Rated current A 2,000, 3,150, 4,000
Rated short-time withstand current kA 50 / 63
Rated short-circuit withstand duration s 3
Rated peak withstand current kA peak 125 / 160
Rated power-frequency withstand voltage (1 min), phase to earth kV 460
Rated power-frequency withstand voltage (1 min), across isolating distance kV 460 + 145
Rated lightning impulse withstand voltage, phase to earth kV peak 1,050
Rated lightning impulse withstand voltage, across isolating distance kV peak 1,050 + 200
Mechanical endurance operations 10,000
Terminal static load (longitudinal / transverse / vertical) N 2,500 / 1,500 / 1,250
Bus-transfer current switching capability A / V 1,600 / 100
Creepage distance mm 6,300 / 7,812
Operating altitude m ≤ 2,000
Pollution level per IEC 60815 class IV (very heavy)
Radio interference voltage (RIV) µV ≤ 500

 Operating Mechanism

Item 252 kV
Disconnector mechanism Motor (three-pole linkage)
Earthing switch mechanism Manual (three-pole linkage)
Motor voltage AC 380 V / DC 220 V
Control voltage AC 220 V / DC 220 V / DC 110 V
Opening / closing time 12 s ± 1 s

 Application Scenarios

  • 220 kV / 230 kV transmission substations:Line and busbar isolation in networks using IEEE or IEC nominal voltages
  • 245 kV / 252 kV regional grid substations :Primary isolation equipment in national transmission grids
  • Cross-border interconnection projects:Single product qualified for 220 kV to 252 kV range eliminates separate qualification for each nominal voltage
  • Substation brownfield expansion;Standard phase spacing compatible with existing 252 kV switchgear layouts
  • EPC transmission projects : Unified supply for multi-country projects with different nominal voltage standards

Order Information

When ordering, specify:

  • Product model and rated voltage
  • Nominal system voltage (220, 230, 245, or 252 kV)
  • Rated current and rated short-time withstand current
  • Earthing switch configuration (none, left, right, or both sides)
  • Arrangement form (right-angle or parallel)
  • Upper busbar type (soft or hard) and tubular busbar outer diameter
  • Motor voltage and control voltage
  • Number of auxiliary switch contacts
  • Installation method
  • Altitude and pollution level (if different from standard)

Documentation Resource Library High voltage disconnect switch

12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Restricted
12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals 12 to 550kV Center Side Break Disconnect Switch Installation and Instruction Manuals
Installation Manual
English
PDF
Rockwill Electric Group Profile
Public
Rockwill Electric Group Profile Rockwill Electric Group Profile
Brochure
English

Frequently asked questions

Basic Electrical Parameters

  • Rated Voltage: All four models from Siemens, Hitachi Energy, GE, and Pinggao are rated for 550 kV.

  • Rated Current: The Siemens, Hitachi, and Pinggao models are rated for 4000A. The GE PKG Gen3-550 offers a higher rated current of 5000A, making it suitable for applications with higher power flow requirements.

  • Short-Circuit Withstand: All models demonstrate identical performance, with a short-time withstand current of 63 kA for 3 seconds.

  • Peak Withstand Current: All models share the same peak withstand current rating of 171 kA.

330kV is used in some regions of China, 345kV is common in North American power grids, and 400kV is mostly customized for cross-border projects or special industrial scenarios. They have not been incorporated into the global unified universal standard system.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Instrument Transformers and Sensors/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register