Brand | Switchgear parts |
Model NO. | SAFE-TWO-HAND Monitoring Relay |
Rated frequency | 50/60Hz |
Series | SAFE |
SAFE-TWO-HAND safety relay is a very compact universal safety dual hand control device. It complies with EN ISO 13851, type IIIC, and is intended for use in safety circuits designed according to EN 60204-1, such as on stamping machines, punch presses, and bending equipment. Due to its internal error monitoring, dual hand safety relays can be used for applications that comply with safety level 4 of EN ISO 13849-1, SILCL 3 of EN 62061, or type III C of EN ISO 13851.
Safety relay for two-hand monitoring up to SIL3 and Type IIIC
Function
2 safe relay contacts, input per push button 1 N/O, 1 N/C, automatic start, Type IIIC, up to SIL 3 / Cat. 4, PL e, 24 V AC/DC, width: 22.5 mm
Features
2 N/O Safety Contacts
Two-Hand Push Buttons
SIL CL 3 (EN 62061 / IEC 61508)
Type IIIC (EN ISO 13851)
Parameter | Specification |
---|---|
In compliance with | EN ISO 13851, EN 60204-1, EN ISO 13849-1, EN 62061 |
Operating voltage | AC/DC 24 V +/- 10 % |
Power consumption | AC 3.5 VA/DC 1.5 W |
Rated supply frequency | 50 - 60 Hz |
Control voltage at S11 and S22 | DC 24 V |
Control current | typical 2 x 40 mA |
Safety contacts non-delayed | 2 NO |
Max. switching voltage | AC 250 V |
Contact rating of safety contacts
|
AC: 250 V, 1500 VA, 6 A for resistive load
|
Max. total current through all contacts | 12 A |
Minimum contact load | 5 V, 10 mA |
External fuses | 10 A gG |
Release time for the safety relays after release of a button | < 20 ms |
Response delay after actuation of the buttons | < 20 ms |
Synchronization time | 0.5 s |
Max. length of control line | 1000 m at 0.75 mm² |
Wire width | 0.14 - 2.5 mm² |
Tightening moment (Min./Max.) | 0.5 Nm/0.6 Nm |
Contact material | AgSnO₂ |
Service Life | mech. approx. 1×10⁷ |
Test voltage | 2.5 kV (control voltage/contacts) |
Rated impulse withstand voltage, leakage path/air gap | 4 kV (DIN VDE 0110-1) |
Rated insulation voltage | 250 V |
Degree of pollution/Overvoltage category | 2/3 (DIN VDE 0110-0) |
Protection | IP20 |
Temperature range Ambient | -15 °C to +60 °C (max. +40 °C for AC use) |
Temperature range Storage | -15 °C to +85 °C |
Max. altitude | ≤ 2000 m (above sea level) |
Weight approx. | 190 g |
Mounting DIN rail according to EN 60715 | TH35 |