| Muhimmiya | Switchgear parts | 
| Model NO. | SAFE-TWO-HAND Monitoring Relay Relay na Gba Ima Mee Nke Ukwu N'ime SAFE-TWO-HAND | 
| Rated Frequency | 50/60Hz | 
| Siri | SAFE | 
SAFE-TWO-HAND safety relay ni tsohon karamin kontrolu na doka da yake da shi a cikin harkokin zafi. Yana nuna EN ISO 13851, type IIIC, kuma yana neman a yi amfani da shi a cikin harkokin zafi da aka haɗa a cikin EN 60204-1, kamar ake amfani da shi a cikin maimaitar tsakiyar magana, punch presses, da kuma zabar gine. Saboda ita ce ta dogara, dual hand safety relays zai iya amfani da su a cikin abubuwan da suka nuna safiya level 4 ta EN ISO 13849-1, SILCL 3 ta EN 62061, ko type III C ta EN ISO 13851.
Safety relay for two-hand monitoring up to SIL3 and Type IIIC
Function
2 safe relay contacts, input per push button 1 N/O, 1 N/C, automatic start, Type IIIC, up to SIL 3 / Cat. 4, PL e, 24 V AC/DC, width: 22.5 mm
Features
2 N/O Safety Contacts
Two-Hand Push Buttons
SIL CL 3 (EN 62061 / IEC 61508)
Type IIIC (EN ISO 13851)
| Parameter | Specification | 
|---|---|
| In compliance with | EN ISO 13851, EN 60204-1, EN ISO 13849-1, EN 62061 | 
| Operating voltage | AC/DC 24 V +/- 10 % | 
| Power consumption | AC 3.5 VA/DC 1.5 W | 
| Rated supply frequency | 50 - 60 Hz | 
| Control voltage at S11 and S22 | DC 24 V | 
| Control current | typical 2 x 40 mA | 
| Safety contacts non-delayed | 2 NO | 
| Max. switching voltage | AC 250 V | 
| Contact rating of safety contacts
 | 
AC: 250 V, 1500 VA, 6 A for resistive load
 | 
| Max. total current through all contacts | 12 A | 
| Minimum contact load | 5 V, 10 mA | 
| External fuses | 10 A gG | 
| Release time for the safety relays after release of a button | < 20 ms | 
| Response delay after actuation of the buttons | < 20 ms | 
| Synchronization time | 0.5 s | 
| Max. length of control line | 1000 m at 0.75 mm² | 
| Wire width | 0.14 - 2.5 mm² | 
| Tightening moment (Min./Max.) | 0.5 Nm/0.6 Nm | 
| Contact material | AgSnO₂ | 
| Service Life | mech. approx. 1×10⁷ | 
| Test voltage | 2.5 kV (control voltage/contacts) | 
| Rated impulse withstand voltage, leakage path/air gap | 4 kV (DIN VDE 0110-1) | 
| Rated insulation voltage | 250 V | 
| Degree of pollution/Overvoltage category | 2/3 (DIN VDE 0110-0) | 
| Protection | IP20 | 
| Temperature range Ambient | -15 °C to +60 °C (max. +40 °C for AC use) | 
| Temperature range Storage | -15 °C to +85 °C | 
| Max. altitude | ≤ 2000 m (above sea level) | 
| Weight approx. | 190 g | 
| Mounting DIN rail according to EN 60715 | TH35 |