• S Series switching power supply
S Series switching power supply
$24.50
Model
S-500-48
S-500-24
S-500-15
S-500-12
S-400-48
S-400-24
S-400-15
S-400-12
S-350-48
S-350-24
S-350-15
S-350-12
S-350-5
S-320-48
S-320-24
S-320-15
S-320-12
S-250-48
S-250-24
S-250-15
S-250-12
S-200-48
S-200-24
S-200-15
S-200-12
S-200-5
S-180-24
S-180-15
S-180-12
S-150-48
S-150-24
S-150-15
S-150-12
S-145-48
S-145-24
S-145-15
S-145-12
S-145-5
S-120-48
S-120-24
S-120-15
S-120-12
S-120-5
S-100-48
S-100-24
S-100-15
S-100-12
S-100-5
S-75-48
S-75-24
S-75-15
S-75-12
S-75-5
S-60-48
S-60-24
S-60-15
S-60-12
S-50-48
S-50-24
S-50-15
S-50-12
S-35-5
S-25-48
S-25-24
S-25-15
S-25-12
S-25-5
S-15-48
S-15-24
S-15-12
S-15-5
Basic info
Brand Wone Store
Model NO. S Series switching power supply
Rated power 320W
Certification CE
Insulation resistance ≥100MΩ(500VDC)
Wide voltage input range AC100V-260V
rated output of CH1 15V,20A
Wide frequency range 47-63Hz
Series S Series
Product Detail

15 - 3000W Chassis - type Switching Power Supplies without PFC (with an independent housing for easy installation) have a relatively wide power coverage and a relatively sturdy structure, but lack power factor correction. Their application scenarios are concentrated in fields that are cost - sensitive, have lenient energy efficiency standards, and require a certain degree of protection. 

      ●Industrial auxiliary equipment: Such as control power supplies for small conveyor belts, local lighting systems in workshops, power supply modules for non-precision testing instruments, etc. The casing can provide basic dust and moisture protection, and the scenarios where they are used have a high tolerance for power grid harmonics.

      ●Commercial low-cost equipment: Power supplies inside small commercial refrigerators, vending machines, and simple security monitoring host units, etc. These need to be fixedly installed and have requirements for physical protection of the power supply, but do not need to comply with strict energy efficiency regulations.

      ●Regionally characteristic electromechanical products: Small water pumps in some regions, household dehumidifiers (non-energy-saving models), etc. The casing design meets the equipment integration requirements, and there are no mandatory requirements for power factor locally.

      ●Temporary or outdoor equipment: Power supplies for mobile stage lighting, outdoor temporary power supply boxes (for short-term use), etc. The casing can improve durability, and short-term use has limited impact on the power grid.

It should be noted that their application is limited in regions with strict energy efficiency regulations (such as the EU and North America), and they are not suitable for sharing the power grid with precision electronic equipment to avoid abnormalities caused by harmonic interference.

 

Features:

Wattage:15W-3000W

Miniature size, non-PFC 

Universal AC input

LED indicator for power on

Protections:Short Circuit/Over Load/Over Voltage/Over Temp

Built-in EMI filter with tiny ripple

100% full load burn-in test

2 Years Warranty

 

selection reference

 

If you need to know about or order switching power supplies of other specifications, Please check the model selection manual.↓↓↓ 

Or you are welcome to contact us.→→→

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!