• S Series switching power supply
S Series switching power supply
$47.00
Model
S-500-48
S-500-24
S-500-15
S-500-12
S-400-48
S-400-24
S-400-15
S-400-12
S-350-48
S-350-24
S-350-15
S-350-12
S-350-5
S-320-48
S-320-24
S-320-15
S-320-12
S-250-48
S-250-24
S-250-15
S-250-12
S-200-48
S-200-24
S-200-15
S-200-12
S-200-5
S-180-24
S-180-15
S-180-12
S-150-48
S-150-24
S-150-15
S-150-12
S-145-48
S-145-24
S-145-15
S-145-12
S-145-5
S-120-48
S-120-24
S-120-15
S-120-12
S-120-5
S-100-48
S-100-24
S-100-15
S-100-12
S-100-5
S-75-48
S-75-24
S-75-15
S-75-12
S-75-5
S-60-48
S-60-24
S-60-15
S-60-12
S-50-48
S-50-24
S-50-15
S-50-12
S-35-5
S-25-48
S-25-24
S-25-15
S-25-12
S-25-5
S-15-48
S-15-24
S-15-12
S-15-5
Basic info
Brand Wone Store
Model NO. S Series switching power supply
Rated power 500W
Certification CE
Insulation resistance ≥100MΩ(500VDC)
Wide voltage input range AC100V-260V
rated output of CH1 48V,10A
Wide frequency range 47-63Hz
Series S Series
Product Detail

15 - 3000W Chassis - type Switching Power Supplies without PFC (with an independent housing for easy installation) have a relatively wide power coverage and a relatively sturdy structure, but lack power factor correction. Their application scenarios are concentrated in fields that are cost - sensitive, have lenient energy efficiency standards, and require a certain degree of protection. 

      ●Industrial auxiliary equipment: Such as control power supplies for small conveyor belts, local lighting systems in workshops, power supply modules for non-precision testing instruments, etc. The casing can provide basic dust and moisture protection, and the scenarios where they are used have a high tolerance for power grid harmonics.

      ●Commercial low-cost equipment: Power supplies inside small commercial refrigerators, vending machines, and simple security monitoring host units, etc. These need to be fixedly installed and have requirements for physical protection of the power supply, but do not need to comply with strict energy efficiency regulations.

      ●Regionally characteristic electromechanical products: Small water pumps in some regions, household dehumidifiers (non-energy-saving models), etc. The casing design meets the equipment integration requirements, and there are no mandatory requirements for power factor locally.

      ●Temporary or outdoor equipment: Power supplies for mobile stage lighting, outdoor temporary power supply boxes (for short-term use), etc. The casing can improve durability, and short-term use has limited impact on the power grid.

It should be noted that their application is limited in regions with strict energy efficiency regulations (such as the EU and North America), and they are not suitable for sharing the power grid with precision electronic equipment to avoid abnormalities caused by harmonic interference.

 

Features:

Wattage:15W-3000W

Miniature size, non-PFC 

Universal AC input

LED indicator for power on

Protections:Short Circuit/Over Load/Over Voltage/Over Temp

Built-in EMI filter with tiny ripple

100% full load burn-in test

2 Years Warranty

 

selection reference

 

If you need to know about or order switching power supplies of other specifications, Please check the model selection manual.↓↓↓ 

Or you are welcome to contact us.→→→

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!