How do I calculate a number of turn per slot in a single phase or three phase induction motor?

10/19/2024

Calculating the number of turns per slot in a single-phase or three-phase induction motor (also known as an asynchronous motor) involves details of the motor's design and specific parameters. The design of the motor's windings aims to optimize the motor's performance, including efficiency, power factor, and reliability. Below are the general steps and methods to calculate the number of turns per slot:

Overview of Steps

  1. Determine Motor Parameters: Understand the basic parameters of the motor, including rated power, rated voltage, frequency, number of poles, and number of slots.

  2. Calculate Total Turns: Based on the design requirements of the motor, calculate the total number of turns in the windings.

  3. Allocate Turns Per Slot: Distribute the total number of turns among each slot.

Specific Steps

1. Collect Motor Parameters

  • Rated Power (P): The rated output power of the motor.

  • Rated Voltage (U): The operating voltage of the motor.

  • Frequency (f): The power supply frequency, typically 50Hz or 60Hz.

  • Number of Pole Pairs (p): The number of pole pairs, which determines the synchronous speed of the motor.

  • Number of Slots (Z): The number of slots on the stator.

  • Number of Phases (m): Single-phase or three-phase.

2. Calculate Total Turns

Calculating the total number of turns involves understanding the specific design requirements of the motor, such as efficiency, power factor, and maximum current. The total number of turns can be estimated using the following empirical formula:

987b2d8e8b2a928be2a9107cf8366484.jpeg

Where:


  • k is an empirical coefficient that depends on the specific design of the motor.

  • U is the rated voltage of the motor.

  • ϕ is the phase angle, typically  3 for a three-phase motor.


  • Bm is the maximum flux density in the air gap of the motor.

3. Allocate Turns Per Slot

Once the total number of turns is determined, it can be distributed among each slot. For a three-phase motor, the number of turns in each phase winding should be the same, and the number of turns per slot should be evenly distributed to ensure balance. The number of turns per slot can be calculated using the following formula:

ff8d86e2f665f7b831731734d53c71ef.jpeg

Where:

  • Nslot is the number of turns per slot.

  • Z is the total number of slots.

Example Calculation

Assume a three-phase induction motor with the following parameters:

  • Rated Voltage U=400 V

  • Number of Pole p=2 (four-pole motor)

  • Number of Slots Z=36

  • Rated Frequency f=50 Hz

  • Maximum Flux Density Bm=1.5 T

Assuming the empirical coefficient
k=0.05:

373f91f62f50cbb72bb77253690eea16.jpeg

Assuming the total number of turns is 47, distributed among 36 slots:

373f91f62f50cbb72bb77253690eea16.jpeg

Since the actual winding design typically requires the number of turns per slot to be an integer, the total number of turns may need to be adjusted to allow for an even distribution among the slots.

Notes

  • Actual Design: In actual motor designs, the number of turns per slot may need to be adjusted based on the specific requirements and manufacturing processes of the motor.

  • Winding Type: Different types of windings (such as concentrated windings or distributed windings) may affect the calculation of the number of turns per slot.

  • Empirical Data: The empirical coefficient 
    k in the formula may need to be adjusted based on the specific type and design requirements of the motor.

By following these steps, you can roughly calculate the number of turns per slot in a single-phase or three-phase induction motor. However, actual motor design often requires specialized motor design software and extensive practical experience to optimize the winding design.


The Electricity Encyclopedia is dedicated to accelerating the dissemination and application of electricity knowledge and adding impetus to the development and innovation of the electricity industry.

What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
09/02/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
08/29/2025
Transformer Connection Sections
Transformer Connection Sections
Transformer Connection DesignationsThe transformer connection designation indicates the winding connection method and the phase relationship between the line voltages of the primary and secondary windings. It consists of two parts: letters and a number. The letters on the left denote the connection configurations of the high-voltage and low-voltage windings, while the number on the right is an integer from 0 to 11.This number represents the phase shift of the low-voltage winding's line voltage r
08/15/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!