What are the Types of Overhead Conductor ?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What are the Types of Overhead Conductor ?


Overhead Conductor Definition


An overhead conductor is defined as a physical medium used to carry electrical energy across distances in transmission and distribution systems.


Copper vs. Aluminum Conductors


Aluminum conductors are preferred over copper due to cost efficiency and reduced corona discharge, despite having lower conductivity and tensile strength.


Types of Conductors


Overhead conductors include AAC, ACAR, AAAC, and ACSR, each with unique properties and uses.


AAC Characteristics


  • AAC has lower strength and more sag per span length than other conductors, making it suitable for shorter spans at the distribution level.



  • It has slightly better conductivity at lower voltages than ACSR.



  • The cost of AAC is similar to that of ACSR.


ACAR (Aluminium Conductor, Aluminium Reinforce)


  • It is cheaper than AAAC but pro to corrosion.

  • It is most expansive.


AAAC (All Aluminium Alloy Conductor)


d1554b4fefb06702b73edf3635bbfe6c.jpeg


  • It has same construction as AAC except the alloy.



  • Its strength is equal to ACSR but due to absence of steel it is light in weight.



  • The presence of formation of alloy makes it expensive.



  • Due to stronger tensile strength than AAC, it is used for longer spans.


  • It can be used in distribution level i.e. river crossing.


  • It has lesser sag than AAC.


The difference between ACSR and AAAC is the weight. Being lighter in weight, it is used in transmission and sub-transmission where lighter support structure is required such as mountains, swamps etc.


ACSR (Aluminium Conductor Steel Reinforced)


6369fd0f1af7e16c854109a4fc6a1935.jpeg


  • ACSR is used for longer spans while minimizing sag. It may consist of 7 or 19 steel strands surrounded by aluminum strands.



  • The number of strands is represented by x/y/z, where ‘x’ is the number of aluminum strands, ‘y’ is the number of steel strands, and ‘z’ is the diameter of each strand.



  • Strands provide flexibility, prevent breakage and minimize skin effect.



  • The number of strands depends on the application, they may be 7, 19, 37, 61, 91 or more.



  • If the Al and St strands are separated by a filler such as paper then this kind of ACSR is used in EHV lines and called expanded ACSR.


  • Expanded ACSR has larger diameter and hence lower corona losses.



IACS (International Annealed Copper Stand)


It is 100% pure conductor and it is standard for reference.

 

Give a tip and encourage the author!
Recommended
Three-Phase SPD: Types, Wiring & Maintenance Guide
Three-Phase SPD: Types, Wiring & Maintenance Guide
1. What Is a Three-Phase Power Surge Protective Device (SPD)?A three-phase power surge protective device (SPD), also known as a three-phase lightning arrester, is specifically designed for three-phase AC power systems. Its primary function is to limit transient overvoltages caused by lightning strikes or switching operations in the power grid, thereby protecting downstream electrical equipment from damage. The SPD operates based on energy absorption and dissipation: when an overvoltage event occ
James
12/02/2025
Railway 10kV Power Through Lines: Design & Operation Requirements
Railway 10kV Power Through Lines: Design & Operation Requirements
The Daquan Line has a large power load, with numerous and scattered load points along the section. Each load point has a small capacity, with an average of one load point every 2-3 km, so two 10 kV power through lines should be adopted for power supply. High-speed railways use two lines for power supply: primary through line and comprehensive through line. The power sources of the two through lines are taken from the dedicated bus sections fed by the voltage regulators installed in each power di
Edwiin
11/26/2025
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Neutral Grounding Methods for Conventional-Speed Railway Power Systems
Railway power systems primarily consist of automatic block signaling lines, through-feeder power lines, railway substations and distribution stations, and incoming power supply lines. They provide electricity to critical railway operations—including signaling, communications, rolling stock systems, station passenger handling, and maintenance facilities. As an integral part of the national power grid, railway power systems exhibit distinct characteristics of both electrical power engineering and
Echo
11/26/2025
Application of Condition Monitoring Technology in UHV Transmission Lines
Application of Condition Monitoring Technology in UHV Transmission Lines
1. Application of Condition Monitoring Technology in UHV Transmission LinesAt present, the main characteristics of UHV (Ultra-High Voltage) transmission line condition monitoring technology in China are reflected in the following aspects: Comprehensiveness: In general, during the implementation of monitoring technology, supporting facilities and integrated systems are required to ensure effective monitoring performance; High value: UHV transmission line condition monitoring technology is a criti
Echo
11/20/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.