UniGear ZS1 Air-insulated switchgear for power application/Ring Main Unit

  • UniGear ZS1 Air-insulated switchgear for power application/Ring Main Unit

Key attributes

Brand ABB
Model NO. UniGear ZS1 Air-insulated switchgear for power application
Rated voltage 17.5kV
Rated frequency 50/60Hz
Series UniGear ZS1

Product descriptions from the supplier

Description

Description:

UniGear ZS1 is the ABB mainlineglobal switchgear for primary distribution up to 24 kV, 4 000 A,63 kA.The switchgear is manufacturedworldwide and there are more than 700 000 panels currently installed.

UniGear ZS1 is used to distribute electric power in a variety of demanding applications such as on off shore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants.UniGear ZS1 is available as a single busbar, double busbar, back to back or double level solution.

Features

  • Standards: IEC, CSA, GOST, GB/DL.

  • Most of panels classified as LSC2B, PM *.

  • Accessibility type: A.

  • Internal arc class: FLR.

  • Highly customized versions available.

  • Switchgear can be back to wall installed.

Safety

  • Fully type tested according to IEC 62271-200.

  • Fitted with safety interlocks.

  • Circuit breaker racking with closed doors.

UniGear ZS1 panel variants have the most common classification LSC2B, PM. Check other panel variants and their LSC classification in catalogue 1VCP000138.

Switching devices

  • Vacuum circuit breaker with spring actuator.

  • Vacuum circuit breaker with magnetic actuator.

  • SF6 circuit breaker with spring actuator.

  • Vacuum contactor.

  • Switch disconnector.

Current and voltage measurement:

  • Current and voltage sensors.

  • Conventional current and voltage instrument transformers .

Protection and control:

  • Relion® protection and control relays.

Optionally available with:

  • Optical arc fault protection 

  • Ultra Fast Earthing Switch UFES

  • Surge arresters

  • Is-limiter, advanced fault current limiter

  • Smart solutions

Technical parameters

 1.With installed gas exhaust duct 2.Depending on rated feeder current  3. 2 089 – 2 154 mm for 63 kA 4) 42 kV (63 kA version; GB/DL)
 Note: 1 250 A - 40 kA  available at 650 mm panel

Structure diagram

Documentation Resource Library
Public.
UniGear ZS1 Air-insulated switchgear for power application
Operation manual
English
FAQ
Q: What are the key features of ABB’s medium voltage switchgear products?
A: ABB‘s primary medium voltage switchgear products are designed to connect and protect the evolving grid. They feature robust construction, advanced safety mechanisms, high reliability, and ease of maintenance. They are designed to handle high electrical loads and provide efficient power distribution with minimal losses.
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A: Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 580000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 580000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Electrical House (eHouse) Solutions
    Reduce site complexity, improve lead timeABB eHouses are prefabricated transportable substations, designed to house medium voltage and low voltage switchgear, critical power equipment and automation cabinets.An eHouse solution is a cost effective, risk reduced alternative to conventional concrete block and brick construction. Each eHouse module is custom engineered to meet application requirements with respect to equipment layout, site footprint limitations and logistics considerations.Installat
    04/16/2025
  • Improve speed to deployment Modular prefabricated and pre-engineered solutions
    Reduce site works and risk of schedule delays and cost overrunsOverview:With a complicated data center project that has short delivery timelines, prefabricated modular solutions and pre-engineered modular solutions may be the answer.Modular solutions are ideal for enterprise, colocation, edge and cloud data centers, where project replicability and expandability are critical, alongside fast deployment time.Reduce risk by leveraging prefabricated and integrated solutions:Fast track projects with p
    04/16/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.