• UniGear ZS1 Air-insulated switchgear for power application/Ring Main Unit
UniGear ZS1 Air-insulated switchgear for power application/Ring Main Unit
discuss personally
Model
UniGear ZS1-17.5
UniGear ZS1-24
UniGear ZS1-12
Basic info
Brand ABB
Model NO. UniGear ZS1 Air-insulated switchgear for power application
Rated voltage 24kV
Rated frequency 50/60Hz
Series UniGear ZS1
Product Detail

Description:

UniGear ZS1 is the ABB mainlineglobal switchgear for primary distribution up to 24 kV, 4 000 A,63 kA.The switchgear is manufacturedworldwide and there are more than 700 000 panels currently installed.

UniGear ZS1 is used to distribute electric power in a variety of demanding applications such as on off shore platforms, in container or cruise ships, in mines as well as in utility substations, power plants or chemical plants.UniGear ZS1 is available as a single busbar, double busbar, back to back or double level solution.

Features

  • Standards: IEC, CSA, GOST, GB/DL.

  • Most of panels classified as LSC2B, PM *.

  • Accessibility type: A.

  • Internal arc class: FLR.

  • Highly customized versions available.

  • Switchgear can be back to wall installed.

Safety

  • Fully type tested according to IEC 62271-200.

  • Fitted with safety interlocks.

  • Circuit breaker racking with closed doors.

UniGear ZS1 panel variants have the most common classification LSC2B, PM. Check other panel variants and their LSC classification in catalogue 1VCP000138.

Switching devices

  • Vacuum circuit breaker with spring actuator.

  • Vacuum circuit breaker with magnetic actuator.

  • SF6 circuit breaker with spring actuator.

  • Vacuum contactor.

  • Switch disconnector.

Current and voltage measurement:

  • Current and voltage sensors.

  • Conventional current and voltage instrument transformers .

Protection and control:

  • Relion® protection and control relays.

Optionally available with:

  • Optical arc fault protection 

  • Ultra Fast Earthing Switch UFES

  • Surge arresters

  • Is-limiter, advanced fault current limiter

  • Smart solutions

Technical parameters

 1.With installed gas exhaust duct 2.Depending on rated feeder current  3. 2 089 – 2 154 mm for 63 kA 4) 42 kV (63 kA version; GB/DL)
 Note: 1 250 A - 40 kA  available at 650 mm panel

Structure diagram

Know your supplier
ABB
As an authorized distributor of ABB products, we take great pride in our partnership.
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Business Type
Sales
Highest Annual Export (USD)
$580000000
Professional Experience
11 years
Workplace
20000m²
占位
占位
Documents
Public.
UniGear ZS1 Air-insulated switchgear for power application
White paper English
PDF
FAQ
Q: What are the key features of ABB’s medium voltage switchgear products?
A:
ABB‘s primary medium voltage switchgear products are designed to connect and protect the evolving grid. They feature robust construction, advanced safety mechanisms, high reliability, and ease of maintenance. They are designed to handle high electrical loads and provide efficient power distribution with minimal losses.
Q: What standards and certifications that ABB’s medium voltage switchgear products comply with?
A:
Our medium voltage switchgear products comply with international standards such as IEC 62271, GOST, GB/DL. They are also certified by leading industry bodies to ensure the highest levels of safety and performance. ABB also offers medium voltage switchgear products for ANSI standards.
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!