Key attributes

Brand ROCKWILL
Model NO. 13.2kV 12kV 14.5kV 15kV 21.9kV Solid insulation switchgear/Ring Main Unit direct supply
Rated voltage 12kV
Rated frequency 50/60Hz
Series FYG

Product descriptions from the supplier

Description
Description

Pioneer in China's eco-friendly switchgear sector, we have specialized in R&D and manufacturing of SF₆-free switchgear for decades. With core technologies, we have established industry standards. Boasting a fully independent end-to-end production chain, we have built a product matrix of zero-emission and high-reliability eco-friendly switchgear, making us a trusted choice for power grid construction.

13.2kV 12kV 14.5kV 15kV 21.9kV solid insulated switchgear is suitable for middle voltage power distribution system and rated current is 630A/1250A. It is more reliable than the SF6 ring main unit, and is more suitable for a wider range of applications in both of GB standard and IEC standard.

Features

Safety

  • All live parts are sealed or embedded in the epoxy resin and silicon rubber, fully insulated and wholly enclosed structure, safety protection level: IP67.

  • Enhanced phase separation design, independent phase insulation to avoid the fault between phases.

  • Switch working position of each phase could be observed independently, which improves operation safety.

Multi-environmental application

  • Applicable to low temperature areas, high altitude areas, high humidity areas, high corrosion areas, low-lying areas and explosion forbidden places.

Flexibility

  • Standard modular design to facilitate circuit extension, modification and replacement.

  • Feasible to any replacement in both circumstances of any unit in fault and according user needs.

  • Smaller dimension makes it more convenient to be moved, transported or replaced.

Environment-friendly

  • Epoxy resin is employed instead of SF6.

Parameter

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

Description

Unit


Rated voltage

kV

13.2kV 12kV 14.5kV 15kV 21.9kV

Power frequency withstand voltage

phase to phase/earth

kV

42

Power frequency withstand voltage

Between open contacts

kV

48

Impulse withstand voltage phase to phase/earth

kV

75

Impulse withstand voltage

Between open contacts

kV

85

 Rated frequency

Hz

50

 Rated current

A

630

Rated short-time withstand current (4s)

kA

20/25

 Rated peak withstand current

kA

50/63

Rated active load breaking current

A

630

Rated closed loop breaking current

A

630

 Mechanical lifetime

Ops

10000

Environmental Conditions

  • Altitude: ≤2200 m (Enhanced insulation type extendable to 3000 m)

  • Ambient Temperature: -20 ℃ to +45 ℃ (Short-term overload operation at ≤+55 ℃ for ≤3 hours within 24 hours is permissible)

  • Relative Humidity: Daily average ≤92%, monthly average ≤82% (Condensation-free and conductive-dust-free environment)


FAQ for
Q: Which special application scenarios are solid environmentally friendly cabinets suitable for?
A:
It is especially suitable for scenarios with low sealing requirements, harsh environments or extremely high environmental protection requirements, including: 1) Humid coastal areas (no need to worry about gas leakage and moisture intrusion); 2) Industrial parks with much dust and oil pollution (the solid insulation layer is not easy to be polluted); 3) Alpine regions (no risk of gas liquefaction); 4) Urban core areas and ecological reserves (zero gas emissions, in line with environmental protection policies); 5) Narrow space installation (more compact structure, no need to reserve gas maintenance space).
Q: What is the general service life of a solid environmentally friendly cabinet? What are the key influencing factors?
A:
The design service life is usually 20-25 years, which is equivalent to that of traditional SF6 cabinets. The key influencing factors include: 1) Quality of solid insulating materials (such as the anti-aging and anti-ultraviolet properties of epoxy resin); 2) Operating environment (high temperature, high humidity, and corrosive environments will accelerate insulation aging); 3) Maintenance quality (avoid mechanical collision damage to the insulation layer); 4) Short-circuit current impact (frequent short circuits will affect insulation performance).
Q: What are the core differences between solid environmentally friendly cabinets and gas-insulated environmentally friendly cabinets?
A:
The core differences lie in the insulating medium and structural design: 1) Insulating medium: Solid cabinets use solid materials such as epoxy resin, while gas-insulated cabinets use gases such as dry air and nitrogen; 2) Sealing requirements: Solid cabinets do not require sealed cavities, while gas-insulated cabinets need strict sealing to prevent leakage; 3) Self-healing ability: Solid cabinets have no self-healing ability after insulation breakdown, while gas-insulated cabinets have certain self-healing ability; 4) Maintenance focus: Solid cabinets focus on checking the aging of insulation layers, while gas-insulated cabinets focus on monitoring air pressure and dew point.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Investing Wisely: The Compelling Life Cycle Cost of Solid Insulated Switchgear
    "Economy" remains paramount in power equipment procurement decisions. When it comes to Solid Insulated Ring Main Units (SIRMUs), the seemingly higher initial price often causes concern. However, a deeper analysis of their Life Cycle Cost (LCC) reveals a surprisingly compelling economic picture – it emerges as the wiser and ultimately more cost-effective choice.Initial Investment: A Misunderstood Starting PointAdmittedly, the purchase price of a SIRMU can be about 5%-15% higher than tra
    08/15/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.