SS2 Operating Mechainsm For Composite Apparatus

  • SS2 Operating Mechainsm For Composite Apparatus
  • SS2 Operating Mechainsm For Composite Apparatus

Key attributes

Brand Switchgear parts
Model NO. SS2 Operating Mechainsm For Composite Apparatus
Motor Voltage 24V
Series SS2

Product descriptions from the supplier

Description
The range of appliance:

SS2-DS double spring operating mechanism is the operating mechanism of FLRN36B(48)-12D/T100-31.5 indoor AC high voltage SF6 load switch-fuse combination electrical apparatus. It is applicable for XGN15-12 fixed AC metal enclosed cabinet, and it can ensure the safety of the electrical apparatus under total operating model.

Operating instruction

Except the same functions of SS2-口D single spring operating mechanism, Double spring operating mechanism adds a fuse tripping mechanism according to the combination electrical apparatus, leading load switch opening, when fuse is breaking.
Atlention: If changing the same fusion tube for the fuse breaking, please plug the operating handle into the operating hole of the mechanism, anticlockwise rotation, making the transmission of mechanism reset with smaller force, and then, operate by the operating process of the cabinet.

SS2-S boundary dimensions installation dimensions and technical parameter:

SS2 Operating Mechainsm For Composite Apparatus

No.

program name

unit

value

1

rated voltage(motor)

V

DC220V/、110V、 48V. 24V

2

electric operation (energy stored) time

S

≤10

3

average closing speed(with body)

m/s

4.5+1.5

4

average opening speed(with body)

m/s

4.5+1.5

5

the max torque of manual operation

N.m

≤130

6

the max time of activating the release

ms

50-60

7

the power of hitting the release

J

2-5

8

mechanism endurance of the load switch

times

5000

9

mechanism endurance of the grouding switch

times

5000

10

the max attitude of equipment installation

m

2000

11

the max temperature

°C

40

12

the lowest temerature

°C

-25

Fuse tripping mechanism upper and lower holder(new)boundary dimensions:

SS2 Operating Mechainsm For Composite Apparatus






Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.