Brand | Switchgear parts |
Model NO. | SAFE-ESTOP Safety Relay |
Rated frequency | 50/60Hz |
Series | SAFE |
SAFE-ESTOP is a safety relay for emergency stop, safety door and light curtain monitoring up to SIL 3 and Cat. 4, PL e in accordance with EN 62061 / EN 61508 and EN ISO 13849, certified by TÜV Rheinland, 1- or 2-channel operation with or without cross circuit detection, automatic and manual start, 3 safe relay contacts, nominal input voltage: 24 V DC, max. switching capacity 250 V AC / 6 A, pluggable screw terminal blocks
Safety relay for emergency stop buttons, safety door switches and light curtain monitoring
Function
3 safe relay contacts, 1 auxiliary contact, 1- or 2-channel input, auto and manual start, up to SIL 3 / Cat. 4, PL e, 24 V DC, width: 22.5 mm
Features
3 N/O Safety Contacts
1 N/C Auxiliary Contact
PL e, Category 4 (EN ISO 13849-1)
SIL CL 3 (EN 62061 / IEC 61508)
Parameter | Specification |
---|---|
In compliance with | EN 60204 - 1; EN ISO 13849 - 1; IEC 62061; IEC 61508 Parts 1 - 2 and 4 - 7 |
Operating voltage | DC 24 V +/- 10 % |
Power consumption | 2.6 W |
Inrush current | 5 A (approx. 250 μs) |
Pulse suppression (A1/S12/S14) | max. 3 ms (pulse width)/500 ms (pulse rate)
|
Safe contact configuration | 3 non - delayed safety contacts (NO) |
Auxiliary contacts | 1 non - delayed auxiliary contact (NC) |
Max. switching voltage | AC 250 V |
Contact rating of safety contacts (13 - 14, 23 - 24, 33 - 34)
|
AC: 250 V, 2000 VA, 8 A for resistive load
|
Thermal current Ith | Max. 5 A per contact (see total current limit curve) |
Contact rating of auxiliary contact | AC: 250 V, 500 VA, 2 A for resistive load
|
Minimum contact load | 5 V, 10 mA |
External fuses | 10 A gG (NO); 6 A gG (NC) |
Max. switch - on delay | < 50 ms |
Max. switch - off delay | Via A1: < 40 ms; Via S12 or S13/S14 < 20 ms |
Recovery time | < 500 ms |
Wire width | 0.14 - 2.5 mm² |
Tightening moment (Min./Max.) | 0.5 Nm/0.6 Nm |
Contact material | AgSnO₂ |
Service Life | mech. approx. 1×10⁷ |
Rated impulse withstand voltage | 2.5 kV (control voltage/contacts) |
Dielectric strength | 4 kV (DIN VDE 0110 - 1) |
Rated insulation voltage | 250 V |
Degree of pollution/Overvoltage category | 2/3 (DIN VDE 0110 - 0) |
Protection | IP20 |
Temperature range Ambient | - 15 °C to + 55 °C |
Temperature range Storage | - 15 °C to + 85 °C |
Max. altitude | ≤ 2000 m (above sea level) |
Weight approx. | 150 g |
Mounting DIN rail according to EN 60715 | TH35 |